Comparison of the image quality and radiation dose of different scanning modes in head-neck CT angiography

2021 ◽  
pp. 20200428
Author(s):  
Tianle Zhang ◽  
Xue Geng ◽  
Dongxue Li ◽  
Yize Xu ◽  
Yongxia Zhao

Objectives: To analyze and compare the radiation dose and image quality of different CT scanning modes on head-neck CT angiography. Methods: A total of 180 patients were divided into Group A and Group B. The groups were further subdivided according to different scanning modes: subgroups A1, A2, A3, B1, B2, and B3. Subgroups A1 and B1 used conventional CT protocol, subgroups A2 and B2 used the kV-Assist scan mode, and subgroups A3 and B3 used the dual-energy gemstone spectral imaging protocol. The CT dose index and dose–length product were recorded. The objective image quality and subjective image evaluation was conducted by two independent radiologists. Results: The signal-to-noise ratios, contrast-to-noise ratios, and subjective scores of subgroups A3 and B3 were higher than the other subgroups. In subgroups B1 and B2, the subjective scores of 9 patients and 12 patients were lower than 3, respectively. The subjective scores of subgroups B1 and B2 were lower than the other subgroups. There was no statistically significant difference in signal-to-noise ratios, contrast-to-noise ratios, and subjective scores between subgroups A1 and A2. The effective dose of subgroup A2 was 41.7 and 36.4% lower than that in subgroups A1 and A3, respectively (p < 0.05). In Group B, there were no statistically significant differences in CT dose indexvol, dose–length product, and ED among the subgroups (p > 0.05). Conclusion: In the head-neck CT angiography, the kV-Assist scan mode is recommended for patients with body mass index between 18.5 and 34.9 kg m−2; gemstone spectral imaging scanning mode is recommended for patients with body mass index ≥34.9 kg m−2.

2019 ◽  
Vol 25 (1) ◽  
pp. 51-55 ◽  
Author(s):  
Daryoush Khoramian ◽  
Soroush Sistani ◽  
Peyman Hejazi

Abstract Objective: The literature has approved that the use of the concept of diagnostic reference level (DRL) as a part of an optimization process could help to reduce patient doses in diagnostic radiology comprising the Computed Tomography (CT) examinations. There are four public/governmental CT centers in the province (Semnan, Iran) and, to our knowledge, after about 12 years since the launch of the first CT scanner in the province there is no dosimetry information on those CT scanners. The aim of this study was to evaluate CT dose indices with the aim of the establishment of the DRL for head, chest, cervical spine, and abdomen-pelvis examinations. Methods: Scan parameters of 381 patients were collected during two months from 4 CT scanners. The CT dose index (CTDI) was measured using a calibrated ionization chamber on two cylindrical poly methyl methacrylate (PMMA) phantoms. For each sequences, weighted CTDI (CTDIw), volumetric CTDI (CTDIv) and dose length product (DLP) were calculated. The 75th percentile was proposed as the criterion for DRL values. Results: Proposed DRL (CTDIw, CTDIv, DLP) for the head, chest, cervical spine, and abdomen-pelvis were (46.1 mGy, 46.1 mGy, 723 mGy × cm), (13.8 mGy, 12.0 mGy, 377 mGy × cm), (40.0 mGy, 40.0 mGy, 572 mGy × cm) and (14.9 mGy, 12.1 mGy, 524 mGy × cm), respectively. Conclusion: Comparison with the others results from the other countries indicates that the head, chest and abdomen-pelvis scans in our region are lower or in the range of the other studies investigated in terms of dose. In the case of cervical spine scanning it’s necessary to review and regulate scan protocols to reach acceptable dose levels.


2018 ◽  
Vol 59 (12) ◽  
pp. 1458-1465 ◽  
Author(s):  
Stefan Haneder ◽  
Florian Siedek ◽  
Jonas Doerner ◽  
Gregor Pahn ◽  
Nils Grosse Hokamp ◽  
...  

Background A novel, multi-energy, dual-layer spectral detector computed tomography (SDCT) is commercially available now with the vendor’s claim that it yields the same or better quality of polychromatic, conventional CT images like modern single-energy CT scanners without any radiation dose penalty. Purpose To intra-individually compare the quality of conventional polychromatic CT images acquired with a dual-layer spectral detector (SDCT) and the latest generation 128-row single-energy-detector (CT128) from the same manufacturer. Material and Methods Fifty patients underwent portal-venous phase, thoracic-abdominal CT scans with the SDCT and prior CT128 imaging. The SDCT scanning protocol was adapted to yield a similar estimated dose length product (DLP) as the CT128. Patient dose optimization by automatic tube current modulation and CT image reconstruction with a state-of-the-art iterative algorithm were identical on both scanners. CT image contrast-to-noise ratio (CNR) was compared between the SDCT and CT128 in different anatomic structures. Image quality and noise were assessed independently by two readers with 5-point-Likert-scales. Volume CT dose index (CTDIvol), and DLP were recorded and normalized to 68 cm acquisition length (DLP68). Results The SDCT yielded higher mean CNR values of 30.0% ± 2.0% (26.4–32.5%) in all anatomic structures ( P < 0.001) and excellent scores for qualitative parameters surpassing the CT128 (all P < 0.0001) with substantial inter-rater agreement (κ ≥ 0.801). Despite adapted scan protocols the SDCT yielded lower values for CTDIvol (–10.1 ± 12.8%), DLP (−13.1 ± 13.9%), and DLP68 (–15.3 ± 16.9%) than the CT128 (all P < 0.0001). Conclusion The SDCT scanner yielded better CT image quality compared to the CT128 and lower radiation dose parameters.


Author(s):  
David C. Rotzinger ◽  
Salim A. Si-Mohamed ◽  
Jérôme Yerly ◽  
Sara Boccalini ◽  
Fabio Becce ◽  
...  

Abstract Objectives To quantitatively evaluate the impact of virtual monochromatic images (VMI) on reduced-iodine-dose dual-energy coronary computed tomography angiography (CCTA) in terms of coronary lumen segmentation in vitro, and secondly to assess the image quality in vivo, compared with conventional CT obtained with regular iodine dose. Materials and methods A phantom simulating regular and reduced iodine injection was used to determine the accuracy and precision of lumen area segmentation for various VMI energy levels. We retrospectively included 203 patients from December 2017 to August 2018 (mean age, 51.7 ± 16.8 years) who underwent CCTA using either standard (group A, n = 103) or reduced (group B, n = 100) iodine doses. Conventional images (group A) were qualitatively and quantitatively compared with 55-keV VMI (group B). We recorded the location of venous catheters. Results In vitro, VMI outperformed conventional CT, with a segmentation accuracy of 0.998 vs. 1.684 mm2, respectively (p < 0.001), and a precision of 0.982 vs. 1.229 mm2, respectively (p < 0.001), in simulated overweight adult subjects. In vivo, the rate of diagnostic CCTA in groups A and B was 88.4% (n = 91/103) vs. 89% (n = 89/100), respectively, and noninferiority of protocol B was inferred. Contrast-to-noise ratios (CNR) of lumen versus fat and muscle were higher in group B (p < 0.001) and comparable for lumen versus calcium (p = 0.423). Venous catheters were more often placed on the forearm or hand in group B (p < 0.001). Conclusion In vitro, low-keV VMI improve vessel area segmentation. In vivo, low-keV VMI allows for a 40% iodine dose and injection rate reduction while maintaining diagnostic image quality and improves the CNR between lumen versus fat and muscle. Key Points • Dual-energy coronary CT angiography is becoming increasingly available and might help improve patient management. • Compared with regular-iodine-dose coronary CT angiography, reduced-iodine-dose dual-energy CT with low-keV monochromatic image reconstructions performed better in phantom-based vessel cross-sectional segmentation and proved to be noninferior in vivo. • Patients receiving reduced-iodine-dose dual-energy coronary CT angiography often had the venous catheter placed on the forearm or wrist without compromising image quality.


Diagnostics ◽  
2020 ◽  
Vol 10 (8) ◽  
pp. 591
Author(s):  
Nor Azura Muhammad ◽  
Muhammad Khalis Abdul Karim ◽  
Hasyma Abu Hassan ◽  
Mazliana Ahmad Kamarudin ◽  
Jeannie Hsiu Ding Wong ◽  
...  

Pediatrics are more vulnerable to radiation and are prone to dose compared to adults, requiring more attention to computed tomography (CT) optimization. Hence, diagnostic reference levels (DRLs) have been implemented as part of optimization process in order to monitor CT dose and diagnostic quality. The noise index has recently been endorsed to be included as a part of CT optimization in the DRLs report. In this study, we have therefore set local DRLs for pediatric CT examination with a noise index as an indicator of image quality. One thousand one hundred and ninety-two (1192) paediatric patients undergoing CT brain, CT thorax and CT chest-abdomen-pelvis (CAP) examinations were analyzed retrospectively and categorized into four age groups; group 1 (0–1 year), group 2 (1–5 years), group 3 (5–10 years) and group 4 (10–15 years). For each group, data such as the volume-weighted CT dose index (CTDIvol), dose-length product (DLP) and the effective dose (E) were calculated and DRLs for each age group set at 50th percentile were determined. Both CT dose and image noise values between age groups have differed significantly with p-value < 0.05. The highest CTDIvol and DLP values in all age groups with the lowest noise index value reported in the 10–15 age group were found in CT brain examination. In conclusion, there was a significant variation in doses and noise intensity among children of different ages, and the need to change specific parameters to fit the clinical requirement.


2015 ◽  
Vol 26 (9) ◽  
pp. 2937-2946 ◽  
Author(s):  
Stefanie Mangold ◽  
Julian L. Wichmann ◽  
U. Joseph Schoepf ◽  
Sheldon E. Litwin ◽  
Christian Canstein ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document