scholarly journals Contrast enhancement in abdominal computed tomography: influence of photon energy of different scanners

2018 ◽  
Vol 91 (1081) ◽  
pp. 20170285 ◽  
Author(s):  
Narumi Taguchi ◽  
Seitaro Oda ◽  
Takeshi Nakaura ◽  
Daisuke Utsunomiya ◽  
Yoshinori Funama ◽  
...  

Objective: Different CT scanners have different X-ray spectra and photon energies indicating that contrast enhancement vary among scanners. However, this issue has not been fully validated; therefore, we performed phantom and clinical studies to assess this difference. Methods: Two scanners were used: scanner-A and scanner-B. In the phantom study, we compared the contrast enhancement between the scanners at tube voltage peaks of 80, 100 and 120 kVp. Then, we calculated the effective energies of the two CT scanners. In the clinical study, 40 patients underwent abdominal scanning with scanner-A and another 40 patients with scanner-B, with each group using the same scanning protocol. The contrast enhancement of abdominal organs was assessed quantitatively (based on the absolute difference between the attenuation of unenhanced scans and contrast-enhanced scans) and qualitatively. A two-tailed independent Student's t-test and or the Mann–Whitney U test were used to compare the discrepancies. Results: In the phantom study, contrast enhancement for scanner-B was 36.9, 32.6 and 30.8% higher than that for scanner-A at 80, 100 and 120 kVp, respectively. The effective energies were higher for scanner-A than for scanner-B. In the quantitative analysis for the clinical study, scanner-B yielded significantly better contrast enhancement of the hepatic parenchyma, pancreas, kidney, portal vein and inferior vena cava compared with that of scanner-A. The mean visual scores for contrast enhancement were also significantly higher on images obtained by scanner-B than those by scanner-A. Conclusion: There were significant differences in contrast enhancement of the abdominal organs between the compared CT scanners from two different vendors even at the same scanning and contrast parameters. Advances in knowledge: Awareness of the impact of different X-ray energies on the resultant attenuation of contrast material is important when interpreting clinical CT images.

2021 ◽  
Vol 11 (4) ◽  
pp. 271-286
Author(s):  
Robert Cierniak ◽  
Piotr Pluta ◽  
Marek Waligóra ◽  
Zdzisław Szymański ◽  
Konrad Grzanek ◽  
...  

Abstract This paper presents a new image reconstruction method for spiral cone- beam tomography scanners in which an X-ray tube with a flying focal spot is used. The method is based on principles related to the statistical model-based iterative reconstruction (MBIR) methodology. The proposed approach is a continuous-to-continuous data model approach, and the forward model is formulated as a shift-invariant system. This allows for avoiding a nutating reconstruction-based approach, e.g. the advanced single slice rebinning methodology (ASSR) that is usually applied in computed tomography (CT) scanners with X-ray tubes with a flying focal spot. In turn, the proposed approach allows for significantly accelerating the reconstruction processing and, generally, for greatly simplifying the entire reconstruction procedure. Additionally, it improves the quality of the reconstructed images in comparison to the traditional algorithms, as confirmed by extensive simulations. It is worth noting that the main purpose of introducing statistical reconstruction methods to medical CT scanners is the reduction of the impact of measurement noise on the quality of tomography images and, consequently, the dose reduction of X-ray radiation absorbed by a patient. A series of computer simulations followed by doctor’s assessments have been performed, which indicate how great a reduction of the absorbed dose can be achieved using the reconstruction approach presented here.


Author(s):  
Н.Н. Петрищев ◽  
Д.Ю. Семенов ◽  
А.Ю. Цибин ◽  
Г.Ю. Юкина ◽  
А.Е. Беркович ◽  
...  

The purpose. In the study we investigated the impact of the partial blood flow shutdown on structural changes in the rabbit vena cava posterior wall after exposure to high-intensity focused ultrasound (HIFU). Methods. Ultrasound Exposure: frequency of 1.65 MHz, the ultrasound intensity in the focus of 13.6 kW/cm, the area of the focal spot 1 mm, continuous ultrasound, exposure for 3 seconds. Results. Immediately after HIFU exposure all layers of the vein wall showed characteristic signs of thermal damage. A week after exposure structural changes in the intima, media and adventitia was minimal in the part of vessel with preserved blood flow, and after 4 weeks the changes were not revealed. A week after HIFU exposure partial endothelium destruction, destruction of myocytes, disorganization and consolidation of collagen fibers of the adventitia were observed in an isolated segment of the vessel, and in 4 weeks endothelium restored and signs of damage in media and adventitia persisted, but were less obvious than in a week after exposure. Conclusion. The shutdown of blood flow after exposure to HIFU promotes persistent changes in the vein wall. Vein compression appears to be necessary for the obliteration of the vessel, when using HIFU-technology.


Author(s):  
Halit Dogan ◽  
Md Mahbub Alam ◽  
Navid Asadizanjani ◽  
Sina Shahbazmohamadi ◽  
Domenic Forte ◽  
...  

Abstract X-ray tomography is a promising technique that can provide micron level, internal structure, and three dimensional (3D) information of an integrated circuit (IC) component without the need for serial sectioning or decapsulation. This is especially useful for counterfeit IC detection as demonstrated by recent work. Although the components remain physically intact during tomography, the effect of radiation on the electrical functionality is not yet fully investigated. In this paper we analyze the impact of X-ray tomography on the reliability of ICs with different fabrication technologies. We perform a 3D imaging using an advanced X-ray machine on Intel flash memories, Macronix flash memories, Xilinx Spartan 3 and Spartan 6 FPGAs. Electrical functionalities are then tested in a systematic procedure after each round of tomography to estimate the impact of X-ray on Flash erase time, read margin, and program operation, and the frequencies of ring oscillators in the FPGAs. A major finding is that erase times for flash memories of older technology are significantly degraded when exposed to tomography, eventually resulting in failure. However, the flash and Xilinx FPGAs of newer technologies seem less sensitive to tomography, as only minor degradations are observed. Further, we did not identify permanent failures for any chips in the time needed to perform tomography for counterfeit detection (approximately 2 hours).


2021 ◽  
Vol 13 (1) ◽  
Author(s):  
Matthew G. Hanson ◽  
Barry Chan

Abstract Background Symptomatic pericardial effusion (PCE) presents with non-specific features and are often missed on the initial physical exam, chest X-ray (CXR), and electrocardiogram (ECG). In extreme cases, misdiagnosis can evolve into decompensated cardiac tamponade, a life-threatening obstructive shock. The purpose of this study is to evaluate the impact of point-of-care ultrasound (POCUS) on the diagnosis and therapeutic intervention of clinically significant PCE. Methods In a retrospective chart review, we looked at all patients between 2002 and 2018 at a major Canadian academic hospital who had a pericardiocentesis for clinically significant PCE. We extracted the rate of presenting complaints, physical exam findings, X-ray findings, ECG findings, time-to-diagnosis, and time-to-pericardiocentesis and how these were impacted by POCUS. Results The most common presenting symptom was dyspnea (64%) and the average systolic blood pressure (SBP) was 120 mmHg. 86% of people presenting had an effusion > 1 cm, and 89% were circumferential on departmental echocardiogram (ECHO) with 64% having evidence of right atrial systolic collapse and 58% with early diastolic right ventricular collapse. The average time-to-diagnosis with POCUS was 5.9 h compared to > 12 h with other imaging including departmental ECHO. Those who had the PCE identified by POCUS had an average time-to-pericardiocentesis of 28.1 h compared to > 48 h with other diagnostic modalities. Conclusion POCUS expedites the diagnosis of symptomatic PCE given its non-specific clinical findings which, in turn, may accelerate the time-to-intervention.


Polymers ◽  
2021 ◽  
Vol 13 (13) ◽  
pp. 2212
Author(s):  
Worawat Poltabtim ◽  
Ekachai Wimolmala ◽  
Teerasak Markpin ◽  
Narongrit Sombatsompop ◽  
Vichai Rosarpitak ◽  
...  

The potential utilization of wood/polyvinyl chloride (WPVC) composites containing an X-ray protective filler, namely bismuth oxide (Bi2O3) particles, was investigated as novel, safe, and environmentally friendly X-ray shielding materials. The wood and Bi2O3 contents used in this work varied from 20 to 40 parts per hundred parts of PVC by weight (pph) and from 0 to 25, 50, 75, and 100 pph, respectively. The study considered X-ray shielding, mechanical, density, water absorption, and morphological properties. The results showed that the overall X-ray shielding parameters, namely the linear attenuation coefficient (µ), mass attenuation coefficient (µm), and lead equivalent thickness (Pbeq), of the WPVC composites increased with increasing Bi2O3 contents but slightly decreased at higher wood contents (40 pph). Furthermore, comparative Pbeq values between the wood/PVC composites and similar commercial X-ray shielding boards indicated that the recommended Bi2O3 contents for the 20 pph (40 ph) wood/PVC composites were 35, 85, and 40 pph (40, 100, and 45 pph) for the attenuation of 60, 100, and 150-kV X-rays, respectively. In addition, the increased Bi2O3 contents in the WPVC composites enhanced the Izod impact strength, hardness (Shore D), and density, but reduced water absorption. On the other hand, the increased wood contents increased the impact strength, hardness (Shore D), and water absorption but lowered the density of the composites. The overall results suggested that the developed WPVC composites had great potential to be used as effective X-ray shielding materials with Bi2O3 acting as a suitable X-ray protective filler.


2020 ◽  
Vol 41 (S1) ◽  
pp. s111-s112
Author(s):  
Mohammed Alsuhaibani ◽  
Mohammed Alzunitan ◽  
Kyle Jenn ◽  
Daniel Diekema ◽  
Michael Edmond ◽  
...  

Background: Surveillance for surgical site infections (SSI) is recommended by the CDC. Currently, colon and abdominal hysterectomy SSI rates are publicly available and impact hospital reimbursement. However, the CDC NHSN allows surgical procedures to be abstracted based on International Classification of Diseases, Tenth Revision (ICD-10) or current procedural terminology (CPT) codes. We assessed the impact of using ICD and/or CPT codes on the number of cases abstracted and SSI rates. Methods: We retrieved administrative codes (ICD and/or CPT) for procedures performed at the University of Iowa Hospitals & Clinics over 1 year: October 2018–September 2019. We included 10 procedure types: colon, hysterectomy, cesarean section, breast, cardiac, craniotomy, spinal fusion, laminectomy, hip prosthesis, and knee prosthesis surgeries. We then calculated the number of procedures that would be abstracted if we used different permutations in administration codes: (1) ICD codes only, (2) CPT codes only, (3) both ICD and CPT codes, and (4) at least 1 code from either ICD or CPT. We then calculated the impact on SSI rates based on any of the 4 coding permutations. Results: In total, 9,583 surgical procedures and 180 SSIs were detected during the study period using the fourth method (ICD or CPT codes). Denominators varied according to procedure type and coding method used. The number of procedures abstracted for breast surgery had a >10-fold difference if reported based on ICD only versus ICD or CPT codes (104 vs 1,109). Hip prosthesis had the lowest variation (638 vs 767). For SSI rates, cesarean section showed almost a 3-fold increment (2.6% when using ICD only to 7.32% with both ICD & CPT), whereas abdominal hysterectomy showed nearly a 2-fold increase (1.14% when using CPT only to 2.22% with both ICD & CPT codes). However, SSI rates remained fairly similar for craniotomy (0.14% absolute difference), hip prosthesis (0.24% absolute difference), and colon (0.09% absolute difference) despite differences in the number of abstracted procedures and coding methods. Conclusions: Denominators and SSI rates vary depending on the coding method used. Variations in the number of procedures abstracted and their subsequent impact on SSI rates were not predictable. Variations in coding methods used by hospitals could impact interhospital comparisons and benchmarking, potentially leading to disparities in public reporting and hospital penalties.Funding: NoneDisclosures: None


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Mikolaj Grabowski ◽  
Ewa Grzanka ◽  
Szymon Grzanka ◽  
Artur Lachowski ◽  
Julita Smalc-Koziorowska ◽  
...  

AbstractThe aim of this paper is to give an experimental evidence that point defects (most probably gallium vacancies) induce decomposition of InGaN quantum wells (QWs) at high temperatures. In the experiment performed, we implanted GaN:Si/sapphire substrates with helium ions in order to introduce a high density of point defects. Then, we grew InGaN QWs on such substrates at temperature of 730 °C, what caused elimination of most (but not all) of the implantation-induced point defects expanding the crystal lattice. The InGaN QWs were almost identical to those grown on unimplanted GaN substrates. In the next step of the experiment, we annealed samples grown on unimplanted and implanted GaN at temperatures of 900 °C, 920 °C and 940 °C for half an hour. The samples were examined using Photoluminescence, X-ray Diffraction and Transmission Electron Microscopy. We found out that the decomposition of InGaN QWs started at lower temperatures for the samples grown on the implanted GaN substrates what provides a strong experimental support that point defects play important role in InGaN decomposition at high temperatures.


Sign in / Sign up

Export Citation Format

Share Document