Functional geometry of ciliated tentacular arrays in active suspension feeders

1998 ◽  
Vol 201 (18) ◽  
pp. 2575-2589 ◽  
Author(s):  
D Grünbaum ◽  
D Eyre ◽  
A Fogelson

Parallel tentacular structures with lateral cilia that produce suspension-feeding and respiratory flows occur repeatedly in many diverse taxonomic groups. We use a computational hydrodynamic model of flow through ciliated tentacles to simulate flow rates through ciliated tentacle arrays. We examine the functional relationship of one performance measure, flow rate per unit length of array, to geometrical variables, such as cilia length, cilia tip speed and the gap between adjacent tentacles, and to hydrodynamic operating conditions, such as adverse pressure drops across the array. We present a scaling and interpolation scheme to estimate flow rates for a wide range of geometries that span many taxa. Our estimates of flow rate can be coupled with the hydrodynamic characteristics of biological piping systems to understand design trade-offs between components of these systems. As a case study, we apply the model to the blue mussel Mytilus edulis by investigating the effect on performance of changes in the gap between neighboring tentacles. Our model suggests that the observed gaps between tentacles in M. edulis reflect flow-maximizing geometries. Even relatively weak adverse pressure drops have strong effects on flow-maximizing geometries and flow rates. One consequence is that an intermediate range of pressure drops may be unfavorable, suggesting that animals may specialize into high-pressure and low-pressure piping systems associated with differences in organism size and with their strategy for eliminating depleted water.

Author(s):  
B. R. Nichols ◽  
R. L. Fittro ◽  
C. P. Goyne

Many high-speed, rotating machines across a wide range of industrial applications depend on fluid film bearings to provide both static support of the rotor and to introduce stabilizing damping forces into the system through a developed hydrodynamic film wedge. Reduced oil supply flow rate to the bearings can cause cavitation, or a lack of a fully developed film layer, at the leading edge of the bearing pads. Reducing oil flow has the well-documented effects of higher bearing operating temperatures and decreased power losses due to shear forces. While machine efficiency may be improved with reduced lubricant flow, little experimental data on its effects on system stability and performance can be found in the literature. This study looks at overall system performance of a test rig operating under reduced oil supply flow rates by observing steady-state bearing performance indicators and baseline vibrational response of the shaft. The test rig used in this study was designed to be dynamically similar to a high-speed industrial compressor. It consists of a 1.55 m long, flexible rotor supported by two tilting pad bearings with a nominal diameter of 70 mm and a span of 1.2 m. The first bending mode is located at approximately 5,000 rpm. The tiling-pad bearings consist of five pads in a vintage, flooded bearing housing with a length to diameter ratio of 0.75, preload of 0.3, and a load-between-pad configuration. Tests were conducted over a number of operating speeds, ranging from 8,000 to 12,000 rpm, and bearing loads, while systematically reducing the oil supply flow rates provided to the bearings under each condition. For nearly all operating conditions, a low amplitude, broadband subsynchronous vibration pattern was observed in the frequency domain from approximately 0–75 Hz. When the test rig was operated at running speeds above its first bending mode, a distinctive subsynchronous peak emerged from the broadband pattern at approximately half of the running speed and at the first bending mode of the shaft. This vibration signature is often considered a classic sign of rotordynamic instability attributed to oil whip and shaft whirl phenomena. For low and moderate load conditions, the amplitude of this 0.5x subsynchronous peak increased with decreasing oil supply flow rate at all operating speeds. Under the high load condition, the subsynchronous peak was largely attenuated. A discussion on the possible sources of this subsynchronous vibration including self-excited instability and pad flutter forced vibration is provided with supporting evidence from thermoelastohydrodynamic (TEHD) bearing modeling results. Implications of reduced oil supply flow rate on system stability and operational limits are also discussed.


Author(s):  
Kamran Siddiqui ◽  
Wajid A. Chishty

For gas turbines burning liquid fuels, improving fuel spray and combustion characteristics are of paramount importance to reduce emission of pollutants, improve combustor efficiency and adapt to a range of alternative fuels. Effervescent atomization technique, which involves the bubbling of an atomizing gas through aerator holes into the liquid fuel stream, has the potential to give the required spray quality for gas turbine combustion. Bubbling of the liquid stream is presently used in a wide range of other applications as well such as spray drying, waste-water treatment, chemical plants, food processing and bio- and nuclear-reactors. In order to optimize control of the required aeration quality and thus the resulting spray quality over a wide range of operating conditions, it is important that the dynamics of bubble formation, detachment and downstream transport are well understood under these circumstances. The paper reports on an experimental study conducted to investigate the dynamics of gas bubbles in terms of bubble detachment frequency when injected from an orifice that is subjected to a liquid cross-flow. The experiments were conducted over a range of gas and liquid flow rates and at various orientations of the liquid channel. Analyses presented here are based on shadowgraph images of two-phase flow, acquired using a high speed camera and a low intensity light source. An image processing algorithm was developed for the detection and characterization of the bubble dynamics. Results show that bubble detachment frequency is a function of both liquid cross-flow rate and the gas-to-liquid flow rate ratio.


1984 ◽  
Vol 19 (1) ◽  
pp. 87-100
Author(s):  
D. Prasad ◽  
J.G. Henry ◽  
P. Elefsiniotis

Abstract Laboratory studies were conducted to demonstrate the effectiveness of diffused aeration for the removal of ammonia from the effluent of an anaerobic filter treating leachate. The effects of pH, temperature and air flow on the process were studied. The coefficient of desorption of ammonia, KD for the anaerobic filter effluent (TKN 75 mg/L with NH3-N 88%) was determined at pH values of 9, 10 and 11, temperatures of 10, 15, 20, 30 and 35°C, and air flow rates of 50, 120, and 190 cm3/sec/L. Results indicated that nitrogen removal from the effluent of anaerobic filters by ammonia desorption was feasible. Removals exceeding 90% were obtained with 8 hours aeration at pH of 10, a temperature of 20°C, and an air flow rate of 190 cm3/sec/L. Ammonia desorption coefficients, KD, determined at other temperatures and air flow rates can be used to predict ammonia removals under a wide range of operating conditions.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
George Gillard ◽  
Ian M. Griffiths ◽  
Gautham Ragunathan ◽  
Ata Ulhaq ◽  
Callum McEwan ◽  
...  

AbstractCombining external control with long spin lifetime and coherence is a key challenge for solid state spin qubits. Tunnel coupling with electron Fermi reservoir provides robust charge state control in semiconductor quantum dots, but results in undesired relaxation of electron and nuclear spins through mechanisms that lack complete understanding. Here, we unravel the contributions of tunnelling-assisted and phonon-assisted spin relaxation mechanisms by systematically adjusting the tunnelling coupling in a wide range, including the limit of an isolated quantum dot. These experiments reveal fundamental limits and trade-offs of quantum dot spin dynamics: while reduced tunnelling can be used to achieve electron spin qubit lifetimes exceeding 1 s, the optical spin initialisation fidelity is reduced below 80%, limited by Auger recombination. Comprehensive understanding of electron-nuclear spin relaxation attained here provides a roadmap for design of the optimal operating conditions in quantum dot spin qubits.


2005 ◽  
Vol 127 (5) ◽  
pp. 1029-1037 ◽  
Author(s):  
L. O. Schunk ◽  
G. F. Nellis ◽  
J. M. Pfotenhauer

Growing interest in larger scale pulse tubes has focused attention on optimizing their thermodynamic efficiency. For Stirling-type pulse tubes, the performance is governed by the phase difference between the pressure and mass flow, a characteristic that can be conveniently adjusted through the use of inertance tubes. In this paper we present a model in which the inertance tube is divided into a large number of increments; each increment is represented by a resistance, compliance, and inertance. This model can include local variations along the inertance tube and is capable of predicting pressure, mass flow rate, and the phase between these quantities at any location in the inertance tube as well as in the attached reservoir. The model is verified through careful comparison with those quantities that can be easily and reliably measured; these include the pressure variations along the length of the inertance tube and the mass flow rate into the reservoir. These experimental quantities are shown to be in good agreement with the model’s predictions over a wide range of operating conditions. Design charts are subsequently generated using the model and are presented for various operating conditions in order to facilitate the design of inertance tubes for pulse tube refrigerators. These design charts enable the pulse tube designer to select an inertance tube geometry that achieves a desired phase shift for a given level of acoustic power.


Author(s):  
K. Singh ◽  
M. Sharabi ◽  
R. Jefferson-Loveday ◽  
S. Ambrose ◽  
C. Eastwick ◽  
...  

Abstract In the case of aero-engine, thin lubricating film servers dual purpose of lubrication and cooling. Prediction of dry patches or lubricant starved region in bearing or bearing chambers are required for safe operation of these components. In the present work thin liquid film flow is numerically investigated using the framework of the Eulerian thin film model (ETFM) for conditions which exhibit partial wetting phenomenon. This model includes a parameter that requires adjustment to account for the dynamic contact angle. Two different experimental data sets have been used for comparisons against simulations, which cover a wide range of operating conditions including varying the flow rate, inclination angle, contact angle, and liquid-gas surface tension coefficient. A new expression for the model parameter has been proposed and calibrated based on the simulated cases. This is employed to predict film thickness on a bearing chamber which is subjected to a complex multiphase flow. From this study, it is observed that the proposed approach shows good quantitative comparisons of the film thickness of flow down an inclined plate and for the representative bearing chamber. A comparison of model predictions with and without wetting and drying capabilities is also presented on the bearing chamber for shaft speed in the range of 2,500 RPM to 10,000 RPM and flow rate in the range of 0.5 liter per minute (LPM) to 2.5 LPM.


1983 ◽  
Vol 245 (2) ◽  
pp. G257-G264 ◽  
Author(s):  
K. Schulze-Delrieu ◽  
J. P. Wall

The resistance generated by the gastroduodenal junction was measured in isolated cat and rabbit preparations. Cannulas were tied into the antrum and duodenum. Yield pressures were determined by increasing the pressure in one of the cannulas until flow occurred. The junctional segment of the cat maintained a high yield pressure. Yield pressures were similar in the antroduodenal and the duodenogastric direction (12.5 +/- 5.7 vs. 14.8 5.8 cmH2O) and increased on both sides to the same degree following exposure of the preparation to 100 mM [K+] and to 10(-6) M carbachol. These experimental manipulations also led to the occurrence of pressure waves in the antral cannula. Yield pressures were diminished but not abolished by exposure of the preparation to 0 [Ca2+] solution or 10(-6) M isoproterenol. Junctional segments from the rabbit did not maintain a yield pressure. Resistance across the junctional segment of both species was also measured by channeling the outflow of one of the cannulas to a flowmeter. Over a wide range of pressures, flow rates across the junctional segment of the rabbit exceeded those across the junctional segment of the cat. Carbachol and 100 mM [K+] decreased the base-line flow and increased the amplitude of intermittent decreases of flow. Isoproterenol and 0 [Ca2+] had opposite effects. Inflation of a balloon decreased the flow rate across the rabbit but not the cat junctional segment. Flow rates across the junctional segment did not differ in the antroduodenal and duodenogastric direction. The gastroduodenal junction does not act as an unidirectional valve. Pyloric resistance relates to the structure of the pyloric segment and to phasic and tonic activity of its musculature.


Author(s):  
Jackson B. Marcinichen ◽  
John R. Thome ◽  
Raffaele L. Amalfi ◽  
Filippo Cataldo

Abstract Thermosyphon cooling systems represent the future of datacenter cooling, and electronics cooling in general, as they provide high thermal performance, reliability and energy efficiency, as well as capture the heat at high temperatures suitable for many heat reuse applications. On the other hand, the design of passive two-phase thermosyphons is extremely challenging because of the complex physics involved in the boiling and condensation processes; in particular, the most important challenge is to accurately predict the flow rate in the thermosyphon and thus the thermal performance. This paper presents an experimental validation to assess the predictive capabilities of JJ Cooling Innovation’s thermosyphon simulator against one independent data set that includes a wide range of operating conditions and system sizes, i.e. thermosyphon data for server-level cooling gathered at Nokia Bell Labs. Comparison between test data and simulated results show good agreement, confirming that the simulator accurately predicts heat transfer performance and pressure drops in each individual component of a thermosyphon cooling system (cold plate, riser, evaporator, downcomer (with no fitting parameters), and eventually a liquid accumulator) coupled with operational characteristics and flow regimes. In addition, the simulator is able to design a single loop thermosyphon (e.g. for cooling a single server’s processor), as shown in this study, but also able to model more complex cooling architectures, where many thermosyphons at server-level and rack-level have to operate in parallel (e.g. for cooling an entire server rack). This task will be performed as future work.


1991 ◽  
Vol 58 (4) ◽  
pp. 383-388 ◽  
Author(s):  
Robert J. Grindal ◽  
Andrew W. Walton ◽  
J. Eric Hillerton

SummaryEighteen cows with a wide range of quarter peak flow rates (0·35–2·22 kg/min) were inoculated with Streptococcus agalactiae and Str. dysgalactiae 4 mm into each streak canal every 3 d for 12 d. Thirty of the 72 quarters developed intramammary infection. Mean peak flow rate and length of streak canal of those quarters that became infected were 1·26 ± 0·08 kg/min (mean ± SEM) and 11·47 ± 0·41 mm respectively, compared with 1·01 ± 0·05 kg/min and 12·05 ± 0·35 mm for those that remained uninfected. Logistic regression analysis showed that the probability of infection increased significantly with the increase in peak flow rate (P = O·O1). The influence of streak canal length on new infection, after allowing for the effect of peak flow rate, was not significant at the 5% level (P = 0·07), suggesting that there may be an inverse relationship between teat duct length and infection, but that it is of secondary importance to peak flow rate. If increased mass of milk distends the teat duct by raising intramammary pressure, then quarter susceptibility to infection is further compromised. These results strongly suggest that the benefits of reduced infection from mastitis control, achieved despite dramatic increases in milk flow rate and milk yield, are significantly underestimated.


Author(s):  
Francois G. Louw ◽  
Theodor W. von Backström ◽  
Sybrand J. van der Spuy

Large axial flow fans are used in forced draft air cooled heat exchangers (ACHEs). Previous studies have shown that adverse operating conditions cause certain sectors of the fan, or the fan as a whole to operate at very low flow rates, thereby reducing the cooling effectiveness of the ACHE. The present study is directed towards the experimental and numerical analyses of the flow in the vicinity of an axial flow fan during low flow rates. This is done to obtain the global flow structure up and downstream of the fan. A near-free-vortex fan, designed for specific application in ACHEs, is used for the investigation. Experimental fan testing was conducted in a British Standard 848, type A fan test facility, to obtain the fan characteristic. Both steady-state and time-dependent numerical simulations were performed, depending on the operating condition of the fan, using the Realizable k-ε turbulence model. Good agreement is found between the numerically and experimentally obtained fan characteristic data. Using data from the numerical simulations, the time and circumferentially averaged flow field is presented. At the design flow rate the downstream fan jet mainly moves in the axial and tangential direction, as expected for a free-vortex design criteria, with a small amount of radial flow that can be observed. As the flow rate through the fan is decreased, it is evident that the down-stream fan jet gradually shifts more diagonally outwards, and the region where reverse flow occur between the fan jet and the fan rotational axis increases. At very low flow rates the flow close to the tip reverses through the fan, producing a small recirculation zone as well as swirl at certain locations upstream of the fan.


Sign in / Sign up

Export Citation Format

Share Document