scholarly journals Giraffes and hominins: reductionist model predictions of compressive loads at the spine base for erect exponents of the animal kingdom

Biology Open ◽  
2020 ◽  
pp. bio.057224
Author(s):  
Michael Günther ◽  
Falk Mörl

In humans, compressive stress on intervertebral discs is commonly deployed as a measurand for assessing the loads that act within the spine. Examining this physical quantity is crucially beneficial: the intradiscal pressure can be directly measured in vivo in humans, and is immediately related to compressive stress. Hence, measured intradiscal pressure data are utterly useful for validating such biomechanical animal models that have the spine incorporated, and can, thus, compute compressive stress values. Here, we utilise human intradiscal pressure data to verify the predictions of a reductionist spine model, which has in fact only one joint degree of freedom. We calculate the pulling force of one lumped anatomical structure that acts past this (intervertebral) joint at the base of the spine—lumbar in hominins, cervical in giraffes—to compensate the torque that is induced by the weight of all masses located cranially to the base. Given morphometric estimates of the human and australopith trunks, respectively, and the giraffe's neck, as well as the respective structures’ lever arms and disc areas, we predict, for all three species, the compressive stress on the intervertebral disc at the spine base, while systematically varying the angular orientation of the species’ spinal columns with respect to gravity. The comparison between these species demonstrates that hominin everyday compressive disc stresses are lower than such in big quadrupedal animals. Within each species, erecting the spine from being bent forward by, for example, thirty degrees to fully upright posture reduces the compressive disc stress roughly to a third. We conclude that erecting the spine immediately allows to carry extra loads of the order of body weight, and yet the compressive disc stress is lower than in a moderately forward-bent posture with none extra load.

Spine ◽  
2004 ◽  
Vol 29 (12) ◽  
pp. 1320-1324 ◽  
Author(s):  
David J. Polga ◽  
Brian P. Beaubien ◽  
Patricia M. Kallemeier ◽  
Kurt P. Schellhas ◽  
Willam D. Lew ◽  
...  

2003 ◽  
Vol 3 (5) ◽  
pp. 83-84 ◽  
Author(s):  
David Polga ◽  
Brian Beaubien ◽  
Patricia Kallemeier ◽  
Kurt Schellhas ◽  
Willam Lew ◽  
...  

2006 ◽  
Vol 1 (1) ◽  
pp. 56-61 ◽  
Author(s):  
Justin M. Stinnett-Donnelly ◽  
Jeffrey J. MacLean ◽  
James C. Iatridis

The rat tail intervertebral disc has emerged as an important model to examine the mechanisms for mechanically induced degeneration and remodeling. Previous methods used to apply high precision axial compressive loading to a rat tail intervertebral disc in vivo either required anesthesia, or the permanent mounting of a loading device to the animal, and were not well described in the literature. Therefore, a new device to apply compressive loading to the rat tail intervertebral disc was developed and validated. The rat tail compressive loading system utilized a pneumatically driven device weighing 18g, and was capable of delivering a 12.6N sinusoidal or square waveform at frequencies up to 1.0Hz. The system improved on previous methods in its modular construction, relative ease of fabrication, compatibility with existing tail model technology and overall cost effectiveness. The removable system eliminated the need for anesthesia and through a modular, cost effective, design allowed for the simultaneous loading of multiple animals. This system expanded the ability to accurately, ethically, and efficiently apply dynamic compressive loads to the rat tail intervertebral disc for extended periods of time in order to address questions related to disc mechanobiology.


2012 ◽  
Vol 64 (6) ◽  
pp. 1950-1959 ◽  
Author(s):  
Michael B. Ellman ◽  
Jae-Sung Kim ◽  
Howard S. An ◽  
Jeffrey S. Kroin ◽  
Xin Li ◽  
...  

Neurosurgery ◽  
2018 ◽  
Vol 85 (2) ◽  
pp. E350-E359 ◽  
Author(s):  
Ibrahim Hussain ◽  
Stephen R Sloan ◽  
Christoph Wipplinger ◽  
Rodrigo Navarro-Ramirez ◽  
Micaella Zubkov ◽  
...  

AbstractBACKGROUNDOur group has previously demonstrated in vivo annulus fibrosus repair in animal models using an acellular, riboflavin crosslinked, high-density collagen (HDC) gel.OBJECTIVETo assess if seeding allogenic mesenchymal stem cells (MSCs) into this gel yields improved histological and radiographic benefits in an in vivo sheep model of annular injury.METHODSFifteen lumbar intervertebral discs (IVDs) were randomized into 4 groups: intact, injury only, injury + acellular gel treatment, or injury + MSC-seeded gel treatment. Sheep were sacrificed at 6 wk. Disc height index (DHI), Pfirrmann grade, nucleus pulposus area, and T2 relaxation time (T2-RT) were calculated for each IVD and standardized to healthy controls from the same sheep. Quantitative histological assessment was also performed using the Han scoring system.RESULTSAll treated IVDs retained gel plugs on gross assessment and there were no adverse perioperative complications. The MSC-seeded gel treatment group demonstrated statistically significant improvement over other experimental groups in DHI (P = .002), Pfirrmann grade (P < .001), and T2-RT (P = .015). There was a trend for greater Han scores in the MSC-seeded gel-treated discs compared with injury only and acellular gel-treated IVDs (P = .246).CONCLUSIONMSC-seeded HDC gel can be delivered into injured IVDs and maintained safely in live sheep to 6 wk. Compared with no treatment and acellular HDC gel, our data show that MSC-seeded HDC gel improves outcomes in DHI, Pfirrmann grade, and T2-RT. Histological analysis shows improved annulus fibrosus and nucleus pulposus reconstitution and organization over other experimental groups as well.


2012 ◽  
Vol 134 (10) ◽  
Author(s):  
M. L. Roemhildt ◽  
B. D. Beynnon ◽  
M. Gardner-Morse ◽  
K. Anderson ◽  
G. J. Badger

This study describes the first application of a varus loading device (VLD) to the rat hind limb to study the role of sustained altered compressive loading and its relationship to the initiation of degenerative changes to the tibio-femoral joint. The VLD applies decreased compressive load to the lateral compartment and increased compressive load to the medial compartment of the tibio-femoral joint in a controlled manner. Mature rats were randomized into one of three groups: unoperated control, 0% (sham), or 80% body weight (BW). Devices were attached to an animal’s leg to deliver altered loads of 0% and 80% BW to the experimental knee for 12 weeks. Compartment-specific material properties of the tibial cartilage and subchondral bone were determined using indentation tests. Articular cartilage, calcified cartilage, and subchondral bone thicknesses, articular cartilage cellularity, and degeneration score were determined histologically. Joint tissues were sensitive to 12 weeks of decreased compressive loading in the lateral compartment with articular cartilage thickness decreased in the peripheral region, subchondral bone thickness increased, and cellularity of the midline region decreased in the 80% BW group as compared to the 0% BW group. The medial compartment revealed trends for diminished cellularity and aggregate modulus with increased loading. The rat-VLD model provides a new system to evaluate altered quantified levels of chronic in vivo loading without disruption of the joint capsule while maintaining full use of the knee. These results reveal a greater sensitivity of tissue parameters to decreased loading versus increased loading of 80% BW for 12 weeks in the rat. This model will allow future mechanistic studies that focus on the initiation and progression of degenerative changes with increased exposure in both magnitude and time to altered compressive loads.


2021 ◽  
Author(s):  
Sabine Bauer ◽  
Ivanna Kramer

The knowledge about the impact of structure-specific parameters on the biomechanical behavior of a computer model has an essential meaning for the realistic modeling and system improving. Especially the biomechanical parameters of the intervertebral discs, the ligamentous structures and the facet joints are seen in the literature as significant components of a spine model, which define the quality of the model. Therefore, it is important to understand how the variations of input parameters for these components affect the entire model and its individual structures. Sensitivity analysis can be used to gain the required knowledge about the correlation of the input and output variables in a complex spinal model. The present study analyses the influence of the biomechanical parameters of the intervertebral disc using different sensitivity analysis methods to optimize the spine model parameters. The analysis is performed with a multi-body simulation model of the cervical functional spinal unit C6-C7.


2014 ◽  
Vol 136 (4) ◽  
Author(s):  
Robert E. Carey ◽  
Liying Zheng ◽  
Ameet K. Aiyangar ◽  
Christopher D. Harner ◽  
Xudong Zhang

In this paper, we present a new methodology for subject-specific finite element modeling of the tibiofemoral joint based on in vivo computed tomography (CT), magnetic resonance imaging (MRI), and dynamic stereo-radiography (DSX) data. We implemented and compared two techniques to incorporate in vivo skeletal kinematics as boundary conditions: one used MRI-measured tibiofemoral kinematics in a nonweight-bearing supine position and allowed five degrees of freedom (excluding flexion-extension) at the joint in response to an axially applied force; the other used DSX-measured tibiofemoral kinematics in a weight-bearing standing position and permitted only axial translation in response to the same force. Verification and comparison of the model predictions employed data from a meniscus transplantation study subject with a meniscectomized and an intact knee. The model-predicted cartilage-cartilage contact areas were examined against “benchmarks” from a novel in situ contact area analysis (ISCAA) in which the intersection volume between nondeformed femoral and tibial cartilage was characterized to determine the contact. The results showed that the DSX-based model predicted contact areas in close alignment with the benchmarks, and outperformed the MRI-based model: the contact centroid predicted by the former was on average 85% closer to the benchmark location. The DSX-based FE model predictions also indicated that the (lateral) meniscectomy increased the contact area in the lateral compartment and increased the maximum contact pressure and maximum compressive stress in both compartments. We discuss the importance of accurate, task-specific skeletal kinematics in subject-specific FE modeling, along with the effects of simplifying assumptions and limitations.


Sign in / Sign up

Export Citation Format

Share Document