Electrical Parameters for Cable Design

2018 ◽  
pp. 259-316
2020 ◽  
pp. 89-96
Author(s):  
Sergei S. Kapitonov ◽  
Alexei S. Vinokurov ◽  
Sergei V. Prytkov ◽  
Sergei Yu. Grigorovich ◽  
Anastasia V. Kapitonova ◽  
...  

The article describes the results of comprehensive study aiming at increase of quality of LED luminaires and definition of the nature of changes in their correlated colour temperature (CCT) in the course of operation. Dependences of CCT of LED luminaires with remote and close location of phosphor for 10 thousand hours of operation in different electric modes were obtained; the results of comparison between the initial and final radiation spectra of the luminaires are presented; using mathematical statistics methods, variation of luminaire CCT over the service period claimed by the manufacturer is forecast; the least favourable electric operation modes with the highest CCT variation observed are defined. The obtained results have confirmed availability of the problem of variation of CCT of LED luminaires during their operation. Possible way of its resolution is application of more qualitative and therefore expensive LEDs with close proximity of phosphor or LEDs with remote phosphor. The article may be interesting both for manufacturers and consumers of LED light sources and lighting devices using them.


Micromachines ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 585
Author(s):  
Yunjia Li ◽  
Weitao Dou ◽  
Chenyuan Zhou ◽  
Xinyi Wang ◽  
Aijun Yang ◽  
...  

A miniaturized reliability test system for microdevices with controlled environmental parameters is presented. The system is capable of measuring key electrical parameters of the microdevices while controlling the environmental conditions around the microdevices. The test system is compact and thus can be integrated with standard test equipment for microdevices. By using a feed-forward decoupling algorithm, the presented test system is capable of generating a temperature range of 0–120 °C and a humidity range of 20–90% RH (0–55 °C), within a small footprint and weight. The accuracy for temperature and humidity control is ±0.1 °C and ±1% RH (30 °C), respectively. The functionality of the proposed test system is verified by integrating it with a piezo shaker to test the environmental reliability of an electromagnetic vibration energy harvester. The proposed system can be used as a proof-of-technology platform for characterizing the performance of microdevices with controlled environmental parameters.


Agriculture ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 114
Author(s):  
Katarzyna Pentoś ◽  
Krzysztof Pieczarka ◽  
Kamil Serwata

Soil spatial variability mapping allows the delimitation of the number of soil samples investigated to describe agricultural areas; it is crucial in precision agriculture. Electrical soil parameters are promising factors for the delimitation of management zones. One of the soil parameters that affects yield is soil compaction. The objective of this work was to indicate electrical parameters useful for the delimitation of management zones connected with soil compaction. For this purpose, the measurement of apparent soil electrical conductivity and magnetic susceptibility was conducted at two depths: 0.5 and 1 m. Soil compaction was measured for a soil layer at 0–0.5 m. Relationships between electrical soil parameters and soil compaction were modelled with the use of two types of neural networks—multilayer perceptron (MLP) and radial basis function (RBF). Better prediction quality was observed for RBF models. It can be stated that in the mathematical model, the apparent soil electrical conductivity affects soil compaction significantly more than magnetic susceptibility. However, magnetic susceptibility gives additional information about soil properties, and therefore, both electrical parameters should be used simultaneously for the delimitation of management zones.


Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 473
Author(s):  
Haifeng Guo ◽  
Aidong Xu ◽  
Kai Wang ◽  
Yue Sun ◽  
Xiaojia Han ◽  
...  

Electromagnetic coils are one of the key components of many systems. Their insulation failure can have severe effects on the systems in which coils are used. This paper focuses on insulation degradation monitoring and remaining useful life (RUL) prediction of electromagnetic coils. First, insulation degradation characteristics are extracted from coil high-frequency electrical parameters. Second, health indicator is defined based on insulation degradation characteristics to indicate the health degree of coil insulation. Finally, an insulation degradation model is constructed, and coil insulation RUL prediction is performed by particle filtering. Thermal accelerated degradation experiments are performed to validate the RUL prediction performance. The proposed method presents opportunities for predictive maintenance of systems that incorporate coils.


Materials ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3360
Author(s):  
Yakir Dahan ◽  
Eldad Holdengreber ◽  
Elichai Glassner ◽  
Oz Sorkin ◽  
Shmuel E. Schacham ◽  
...  

A new measurement technique of electrical parameters of superconducting thin films at the Very High Frequency (VHF) range is described, based on resonators with microstrip (MS) structures. The design of an optimal resonator was achieved, based on a thorough theoretical analysis, which is required for derivation of the exact configuration of the MS. A theoretical model is presented, from which an expression for the attenuation of a MS line can be derived. Accordingly, simulations were performed, and an optimal resonator for the VHF range was designed and implemented. Production constraints of YBa2Cu3O7 (YBCO) limited the diameter of the sapphire substrate to 3″. Therefore, a meander configuration was formed to fit the long λ/4 MS line on the wafer. By measuring the complex input reflection coefficients of a λ/4 resonator, we extracted the quality factor, which is mainly affected by the dielectric and conductor attenuations. The experimental results are well fitted by the theoretical model. The dielectric attenuation was calculated using the quasi-static analysis of the MS line. An identical copper resonator was produced and measured to compare the properties of the YBCO resonator in reference to the copper one. A quality factor of ~6·105 was calculated for the YBCO resonator, three orders of magnitude larger than that of the copper resonator. The attenuation per unit length of the YBCO layer was smaller by more than five orders of magnitude than that of the copper.


Sign in / Sign up

Export Citation Format

Share Document