Biogenic Hydroxyapatite Based Implant Materials

2015 ◽  
pp. 27-55
Author(s):  
Katalin Balázsi ◽  
Csaba Balázsi
1991 ◽  
Vol 4 (02) ◽  
pp. 38-45 ◽  
Author(s):  
F. Baumgart

SummaryThe so-called “mixing” of implants and instruments from different producers entertain certain risks.The use of standardized implant materials (e.g. stainless steel ISO 5832/1) from different producers is necessary but is not sufficient to justify the use of an osteosynthesis plate from one source and a bone screw from another.The design, dimensions, tolerances, manufacturing procedure, quality controls, and application technique of the instruments and implants also vary according to make. This can lead to damage, failure or fracture of the biomechanical system called “osteosynthesis” and hence the failure of the treatment undertaken. In the end, it is the patient who pays for these problems.Some examples also illustrate the potential problems for the staff and institutions involved.The use of a unique, consistent, well-tested, and approved set of implants and instruments is to be strongly recommended to avoid any additional risk.


Author(s):  
Mohamed Esmail Khalil ◽  
Mohamed Farag Khalil ◽  
Raafat Mohyeldeen Abdelrahman ◽  
Ahmed Mohamed Kamal Elshafei ◽  
Tamer Ismail Gawdat

2021 ◽  
Vol 1017 (1) ◽  
pp. 012038
Author(s):  
Deepika Shekhawat ◽  
Amit Singh ◽  
Ashray Bhardwaj ◽  
Amar Patnaik

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
P. A. Forero-Sossa ◽  
J. D. Salazar-Martínez ◽  
A. L. Giraldo-Betancur ◽  
B. Segura-Giraldo ◽  
E. Restrepo-Parra

AbstractBiogenic hydroxyapatite (BHAp) is a widely used material in the biomedical area due to its similarities with the bone tissue mineral phase. Several works have been spotlighted on the thermal behavior of bone. However, little research has focused on determining the influence of calcination temperature in the physicochemical and bioactive properties of BHAp. In this work, a study of the physicochemical properties’ changes and bioactive response of BHAp produced from porcine femur bones using calcination temperatures between 900 to 1200 °C was conducted. The samples’ structural, morphological, and compositional changes were determined using XRD, SEM, and FTIR techniques. XRD results identified three temperature ranges, in which there are structural changes in BHAp samples and the presence of additional phases. Moreover, FTIR results corroborated that B-type substitution is promoted by increasing the heat treatment temperature. Likewise, samples were immersed in a simulated biological fluid (SBF), following the methodology described by Kokubo and using ISO 23317:2014 standard, for 3 and 7 days. FTIR and SEM results determined that the highest reaction velocity was reached for samples above 1000 °C, due to intensity increasing of phosphate and carbonate bands and bone-like apatite morphologies, compared to other temperatures evaluated.


1985 ◽  
Vol 13 (4) ◽  
pp. 261-266
Author(s):  
P.P. Monro ◽  
D.P. Knight ◽  
W.S. Pringle ◽  
D.M. Fyfe ◽  
J.R. Shearer

The toxicity of implant materials requires investigation prior to clinical use. We have developed a method where materials are directly applied to the chorioallantoic membrane (CAM) of 9-day-old chick embryos and toxicity is assessed using histological criteria. We evaluated the method using metal foils. The number and organisation of fibroblasts seemed to be the most useful criteria for assessing metal toxicity. Differences were greatest after 10 days of culture on the CAM. The method is sensitive enough to enable us to discriminate between the less toxic aluminium and titanium and the highly toxic cobalt, nickel and tungsten. The proposed method has advantages over in vitro techniques which provide an abnormal fluid environment and in which the more complex interactions that are possible between implant materials and tissue in vivo cannot be modelled.


Author(s):  
Mohammed Mousa Bakri ◽  
Sung Ho Lee ◽  
Jong Ho Lee

Abstract Background A compact passive oxide layer can grow on tantalum (Ta). It has been reported that this oxide layer can facilitate bone ingrowth in vivo though the development of bone-like apatite, which promotes hard and soft tissue adhesion. Thus, Ta surface treatment on facial implant materials may improve the tissue response, which could result in less fibrotic encapsulation and make the implant more stable on the bone surface. The purposes of this study were to verify whether surface treatment of facial implant materials using Ta can improve the biohistobiological response and to determine the possibility of potential clinical applications. Methods Two different and commonly used implant materials, silicone and expanded polytetrafluoroethylene (ePTFE), were treated via Ta ion implantation using a Ta sputtering gun. Ta-treated samples were compared with untreated samples using in vitro and in vivo evaluations. Osteoblast (MG-63) and fibroblast (NIH3T3) cell viability with the Ta-treated implant material was assessed, and the tissue response was observed by placing the implants over the rat calvarium (n = 48) for two different lengths of time. Foreign body and inflammatory reactions were observed, and soft tissue thickness between the calvarium and the implant as well as the bone response was measured. Results The treatment of facial implant materials using Ta showed a tendency toward increased fibroblast and osteoblast viability, although this result was not statistically significant. During the in vivo study, both Ta-treated and untreated implants showed similar foreign body reactions. However, the Ta-treated implant materials (silicone and ePTFE) showed a tendency toward better histological features: lower soft tissue thickness between the implant and the underlying calvarium as well as an increase in new bone activity. Conclusion Ta surface treatment using ion implantation on silicone and ePTFE facial implant materials showed the possibility of reducing soft tissue intervention between the calvarium and the implant to make the implant more stable on the bone surface. Although no statistically significant improvement was observed, Ta treatment revealed a tendency toward an improved biohistological response of silicone and ePTFE facial implants. Conclusively, tantalum treatment is beneficial and has the potential for clinical applications.


2019 ◽  
Vol 48 (8) ◽  
pp. 20190139
Author(s):  
Emine Şebnem Kursun-Cakmak ◽  
Husniye Demirturk Kocasarac ◽  
Seval Bayrak ◽  
Gülbahar Ustaoğlu ◽  
Marcel Noujeim

Objectives: To assess the contrast-to-noise ratio (CNR) of four different types of dental implant materials in CT and cone beam CT (CBCT) images with varying scan settings. Methods: Four different types of implants: zirconium (Zr), titanium (Ti) Grade 4 and 5 and titanium–zirconium (Ti–ZrO2) alloy were placed in a 3% gelatin phantom in a cylindrical plastic container and scanned with two different CT machines (GE Medical systems and Toshiba Medical Systems) and one CBCT machine (I-CAT, Imaging Sciences International) with different voxel sizes of 0.2, 0.25, 0.3 and 0.4 mm. Images were analyzed using ImageJ software with the purpose of estimating the CNR. Results: The CNR obtained from images acquired with CT was lower than the CBCT with all voxel sizes tested. 0.3 and 0.4 mm voxel sizes exhibited the highest CNR (p < 0.05) that gives the best image quality. Among the implant materials tested, titanium Grade 5 has the highest levels of CNR while Zirconium has the lowest (p < 0.05). Conclusions: The optimum protocol for radiographic follow-up in areas near implants on the I-CAT is low-resolution settings (0.3 and 0.4 mm voxel sizes) which gave the highest CNR thus image quality. In presence of Zr implants, an alternative imaging modality (i.e., MRI) may be considered to avoid low-quality images.