QUANTITATIVE ASSESSMENT OF FUNGICIDAL AND BACTERICIDAL ACTIVITY OF NANOSTRUCTURAL SILVER PARTICLES

2015 ◽  
pp. 219-232
2020 ◽  
Author(s):  
José‐Carlos Delgado‐González ◽  
Carlos‐de‐la Rosa Prieto ◽  
Nuria Vallejo‐Calcerrada ◽  
Diana‐Lucía Tarruela‐Hernández ◽  
Sandra Cebada‐Sánchez ◽  
...  

Author(s):  
C. F. Oster

Although ultra-thin sectioning techniques are widely used in the biological sciences, their applications are somewhat less popular but very useful in industrial applications. This presentation will review several specific applications where ultra-thin sectioning techniques have proven invaluable.The preparation of samples for sectioning usually involves embedding in an epoxy resin. Araldite 6005 Resin and Hardener are mixed so that the hardness of the embedding medium matches that of the sample to reduce any distortion of the sample during the sectioning process. No dehydration series are needed to prepare our usual samples for embedding, but some types require hardening and staining steps. The embedded samples are sectioned with either a prototype of a Porter-Blum Microtome or an LKB Ultrotome III. Both instruments are equipped with diamond knives.In the study of photographic film, the distribution of the developed silver particles through the layer is important to the image tone and/or scattering power. Also, the morphology of the developed silver is an important factor, and cross sections will show this structure.


Author(s):  
H. Seiler ◽  
U. Haas ◽  
K.H. Körtje

The physical properties of small metal particles reveal an intermediate position between atomic and bulk material. Especially Ag has shown pronounced size effects. We compared silver layers evaporated in high vacuum with cluster layers of small silver particles, evaporated in N2 at a pressure of about 102 Pa. The investigations were performed by electron optical methods (TEM, SEM, EELS) and by Photoacoustic (PA) Spectroscopy (gas-microphone detection).The observation of cluster layers with TEM and high resolution SEM show small silver particles with diameters of about 50 nm (Fig. 1 and Figure 2, respectively). The electron diffraction patterns of homogeneous Ag layers and of cluster layers are similar, whereas the low loss EELS spectra due to plasmon excitation are quite different. Fig. 3 and Figure 4 show first results of EELS spectra of a cluster layer of small silver particles on carbon foil and of a homogeneous Ag layer, respectively.


VASA ◽  
2017 ◽  
Vol 46 (5) ◽  
pp. 383-388 ◽  
Author(s):  
Henrik Christian Rieß ◽  
Anna Duprée ◽  
Christian-Alexander Behrendt ◽  
Tilo Kölbel ◽  
Eike Sebastian Debus ◽  
...  

Abstract. Background: Perioperative evaluation in peripheral artery disease (PAD) by common vascular diagnostic tools is limited by open wounds, medial calcinosis or an altered collateral supply of the foot. Indocyanine green fluorescent imaging (ICG-FI) has recently been introduced as an alternative tool, but so far a standardized quantitative assessment of tissue perfusion in vascular surgery has not been performed for this purpose. The aim of this feasibility study was to investigate a new software for quantitative assessment of tissue perfusion in patients with PAD using indocyanine green fluorescent imaging (ICG-FI) before and after peripheral bypass grafting. Patients and methods: Indocyanine green fluorescent imaging was performed in seven patients using the SPY Elite system before and after peripheral bypass grafting for PAD (Rutherford III-VI). Visual and quantitative evaluation of tissue perfusion was assessed in an area of low perfusion (ALP) and high perfusion (AHP), each by three independent investigators. Data assessment was performed offline using a specially customized software package (Institute for Laser Technology, University Ulm, GmbH). Slope of fluorescent intensity (SFI) was measured as time-intensity curves. Values were compared to ankle-brachial index (ABI), slope of oscillation (SOO), and time to peak (TTP) obtained from photoplethysmography (PPG). Results: All measurements before and after surgery were successfully performed, showing that ABI, TTP, and SOO increased significantly compared to preoperative values, all being statistically significant (P < 0.05), except for TTP (p = 0.061). Further, SFI increased significantly in both ALP and AHP (P < 0.05) and correlated considerably with ABI, TTP, and SOO (P < 0.05). Conclusions: In addition to ABI and slope of oscillation (SOO), the ICG-FI technique allows visual assessment in combination with quantitative assessment of tissue perfusion in patients with PAD. Ratios related to different perfusion patterns and SFI seem to be useful tools to reduce factors disturbing ICG-FI measurements.


Sign in / Sign up

Export Citation Format

Share Document