Volume-of-interest imaging

2014 ◽  
pp. 133-140
Keyword(s):  
Author(s):  
P.M. Houpt ◽  
A. Draaijer

In confocal microscopy, the object is scanned by the coinciding focal points (confocal) of a point light source and a point detector both focused on a certain plane in the object. Only light coming from the focal point is detected and, even more important, out-of-focus light is rejected.This makes it possible to slice up optically the ‘volume of interest’ in the object by moving it axially while scanning the focused point light source (X-Y) laterally. The successive confocal sections can be stored in a computer and used to reconstruct the object in a 3D image display.The instrument described is able to scan the object laterally with an Ar ion laser (488 nm) at video rates. The image of one confocal section of an object can be displayed within 40 milliseconds (1000 х 1000 pixels). The time to record the total information within the ‘volume of interest’ normally depends on the number of slices needed to cover it, but rarely exceeds a few seconds.


Author(s):  
John B. Vander Sande ◽  
Thomas F. Kelly ◽  
Douglas Imeson

In the scanning transmission electron microscope (STEM) a fine probe of electrons is scanned across the thin specimen, or the probe is stationarily placed on a volume of interest, and various products of the electron-specimen interaction are then collected and used for image formation or microanalysis. The microanalysis modes usually employed in STEM include, but are not restricted to, energy dispersive X-ray analysis, electron energy loss spectroscopy, and microdiffraction.


Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3070
Author(s):  
Sebastian Iwaszenko ◽  
Jakub Munk ◽  
Stefan Baron ◽  
Adam Smoliński

Modern dentistry commonly uses a variety of imaging methods to support diagnosis and treatment. Among them, cone beam computed tomography (CBCT) is particularly useful in presenting head structures, such as the temporomandibular joint (TMJ). The determination of the morphology of the joint is an important part of the diagnosis as well as the monitoring of the treatment results. It can be accomplished by measurement of the TMJ gap width at three selected places, taken at a specific cross-section. This study presents a new approach to these measurements. First, the CBCT images are denoised using curvilinear methods, and the volume of interest is determined. Then, the orientation of the vertical cross-section plane is computed based on segmented axial sections of the TMJ head. Finally, the cross-section plane is used to determine the standardized locations, at which the width of the gap between condyle and fossa is measured. The elaborated method was tested on selected TMJ CBCT scans with satisfactory results. The proposed solution lays the basis for the development of an autonomous method of TMJ index identification.


Author(s):  
Volker A. Coenen ◽  
Bastian E. Sajonz ◽  
Peter C. Reinacher ◽  
Christoph P. Kaller ◽  
Horst Urbach ◽  
...  

Abstract Background An increasing number of neurosurgeons use display of the dentato-rubro-thalamic tract (DRT) based on diffusion weighted imaging (dMRI) as basis for their routine planning of stimulation or lesioning approaches in stereotactic tremor surgery. An evaluation of the anatomical validity of the display of the DRT with respect to modern stereotactic planning systems and across different tracking environments has not been performed. Methods Distinct dMRI and anatomical magnetic resonance imaging (MRI) data of high and low quality from 9 subjects were used. Six subjects had repeated MRI scans and therefore entered the analysis twice. Standardized DICOM structure templates for volume of interest definition were applied in native space for all investigations. For tracking BrainLab Elements (BrainLab, Munich, Germany), two tensor deterministic tracking (FT2), MRtrix IFOD2 (https://www.mrtrix.org), and a global tracking (GT) approach were used to compare the display of the uncrossed (DRTu) and crossed (DRTx) fiber structure after transformation into MNI space. The resulting streamlines were investigated for congruence, reproducibility, anatomical validity, and penetration of anatomical way point structures. Results In general, the DRTu can be depicted with good quality (as judged by waypoints). FT2 (surgical) and GT (neuroscientific) show high congruence. While GT shows partly reproducible results for DRTx, the crossed pathway cannot be reliably reconstructed with the other (iFOD2 and FT2) algorithms. Conclusion Since a direct anatomical comparison is difficult in the individual subjects, we chose a comparison with two research tracking environments as the best possible “ground truth.” FT2 is useful especially because of its manual editing possibilities of cutting erroneous fibers on the single subject level. An uncertainty of 2 mm as mean displacement of DRTu is expectable and should be respected when using this approach for surgical planning. Tractographic renditions of the DRTx on the single subject level seem to be still illusive.


2008 ◽  
Vol 109 (2) ◽  
pp. 306-312 ◽  
Author(s):  
Andreas Stadlbauer ◽  
Michael Buchfelder ◽  
Christopher Nimsky ◽  
Wolfgang Saeger ◽  
Erich Salomonowitz ◽  
...  

Object The aim of this study was to correlate proton MR (1H-MR) spectroscopy data with histopathological and surgical findings of proliferation and hemorrhage in pituitary macroadenomas. Methods Quantitative 1H-MR spectroscopy was performed on a 1.5-T unit in 37 patients with pituitary macroadenomas. A point-resolved spectroscopy sequence (TR 2000 msec, TE 135 msec) with 128 averages and chemical shift selective pulses for water suppression was used. Voxel dimensions were adapted to ensure that the volume of interest was fully located within the lesion and to obtain optimal homogeneity of the magnetic field. In addition, water-unsuppressed spectra (16 averages) were acquired from the same volume of interest for eddy current correction, absolute quantification of metabolite signals, and determination of full width at half maximum of the unsuppressed water peak (FWHMwater). Metabolite concentrations of choline-containing compounds (Cho) were computed using the LCModel program and correlated with MIB-1 as a proliferative cell index from a tissue specimen. Results In 16 patients harboring macroadenomas without hemorrhage, there was a strong positive linear correlation between metabolite concentrations of Cho and the MIB-1 proliferative cell index (R = 0.819, p < 0.001). The metabolite concentrations of Cho ranged from 1.8 to 5.2 mM, and the FWHMwater was 4.4–11.7 Hz. Eleven patients had a hemorrhagic adenoma and showed no assignable metabolite concentration of Cho, and the FWHMwater was 13.4–24.4 Hz. In 10 patients the size of the lesion was too small (< 20 mm in 2 directions) for the acquisition of MR spectroscopy data. Conclusions Quantitative 1H-MR spectroscopy provided important information on the proliferative potential and hemorrhaging of pituitary macroadenomas. These data may be useful for noninvasive structural monitoring of pituitary macroadenomas. Differences in the FWHMwater could be explained by iron ions of hemosiderin, which lead to worsened homogeneity of the magnetic field.


2018 ◽  
Vol 8 (1) ◽  
Author(s):  
Marc G. Stevenson ◽  
Lukas B. Been ◽  
Harald J. Hoekstra ◽  
Albert J. H. Suurmeijer ◽  
Ronald Boellaard ◽  
...  

2021 ◽  
Vol 5 (1) ◽  
Author(s):  
Hendrik Joost Wisselink ◽  
Gert Jan Pelgrim ◽  
Mieneke Rook ◽  
Ivan Dudurych ◽  
Maarten van den Berge ◽  
...  

AbstractAssessment of image noise is a relevant issue in computed tomography (CT). Noise is routinely measured by the standard deviation of density values (Hounsfield units, HU) within a circular region of interest (ROI). We explored the effect of a spherical volume of interest (VOI) on noise measurements. Forty-nine chronic obstructive pulmonary disease patients underwent CT with clinical protocol (regular dose [RD], volumetric CT dose index [CTDIvol] 3.04 mGy, 64-slice unit), and ultra-low dose (ULD) protocol (median CTDIvol 0.38 mGy, dual-source unit). Noise was measured in 27 1-cm2 ROIs and 27 0.75-cm3 VOIs inside the trachea. Median true noise was 21 HU (range 17-29) for RD-CT and 33 HU (26-39) for ULD-CT. The VOI approach resulted in a lower mean distance between limits of agreement compared to ROI: 5.9 versus 10.0 HU for RD-CT (−40%); 4.7 versus 9.9 HU for ULD-CT (−53%). Mean systematic bias barely changed: −1.6 versus −0.9HU for RD-CT; 0.0 to 0.4HU for ULD-CT. The average measurement time was 6.8 s (ROI) versus 9.7 (VOI), independent of dose level. For chest CT, measuring noise with a VOI-based instead of a ROI-based approach reduces variability by 40-53%, without a relevant effect on systematic bias and measurement time.


2021 ◽  
Author(s):  
Yoon-Sang Oh ◽  
Sang-Won Yoo ◽  
Chul Hyoung Lyoo ◽  
Joong-Seok Kim

Abstract Drug-induced parkinsonism (DIP) is caused by a dopamine receptor blockade and is a major cause of misleading diagnosis of Parkinson’s disease (PD). Striatal dopamine activity has been investigated widely in DIP; however, most studies with dopamine transporter imaging have focused on the clinical characteristics and prognosis. This study investigated differences in striatal subregional monoamine availability among patients with DIP, normal controls, and patients with early PD. Thirty-five DIP patients, the same number of age-matched PD patients, and 46 healthy controls were selected for this study. Parkinsonian motor status was examined. Brain magnetic resonance imaging and positron emission tomography with 18F-N-(3-fluoropropyl)-2beta-carbon ethoxy-3beta-(4-iodophenyl) nortropane were performed, and the regional standardized uptake values were analyzed with a volume-of-interest template and compared among the groups. Females were more predominant in the DIP group than in the PD group. Parkinsonian motor symptoms were similar in the DIP and PD groups. Monoamine availability in the thalamus of the DIP group was lower than that of the normal controls and similar to that of the PD group. In other subregions (putamen, globus pallidus, and ventral striatum), monoamine availability in the DIP group and normal controls did not differ and was higher than that in the PD group. These findings suggest that low monoamine availability in the thalamus could be an imaging biomarker of DIP.


PLoS ONE ◽  
2020 ◽  
Vol 15 (6) ◽  
pp. e0234871 ◽  
Author(s):  
Aydin Demircioglu ◽  
Johannes Grueneisen ◽  
Marc Ingenwerth ◽  
Oliver Hoffmann ◽  
Katja Pinker-Domenig ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document