BIM based FM and building operation

Keyword(s):  
Encyclopedia ◽  
2021 ◽  
Vol 1 (2) ◽  
pp. 472-481
Author(s):  
Nasim Aghili ◽  
Mehdi Amirkhani

Green buildings refer to buildings that decrease adverse environmental effects and maintain natural resources. They can diminish energy consumption, greenhouse gas emissions, the usage of non-renewable materials, water consumption, and waste generation while improving occupants’ health and well-being. As such, several rating tools and benchmarks have been developed worldwide to assess green building performance (GBP), including the Building Research Establishment Environmental Assessment Method (BREEAM) in the United Kingdom, German Sustainable Building Council (DGNB), Leadership in Energy and Environmental Design (LEED) in the United States and Canada, Comprehensive Assessment System for Built Environment Efficiency (CASBEE) in Japan, Green Star in Australia, Green Mark in Singapore, and Green Building Index in Malaysia. Energy management (EM) during building operation could also improve GBP. One of the best approaches to evaluating the impact of EM on GBP is by using structural equation modelling (SEM). SEM is a commanding statistical method to model testing. One of the most used SEM variance-based approaches is partial least squares (PLS), which can be implemented in the SmartPLS application. PLS-SEM uses path coefficients to determine the strength and significance of the hypothesised relationships between the latent constructs.


2019 ◽  
Vol 13 (2) ◽  
pp. 129-133
Author(s):  
Gennadiy Farenyuk

The paper presents the basic methodical principles for the time analysis of the variations of envelope structures’ thermal insulation properties and for the substantiation of the thermal reliability criterion, which should allow the analysis of the actual parameters of heat losses during the operation of buildings. In the paper, the state of the envelope structures thermal failure, the concept of building thermal envelope thermal reliability and the principles of its rating are defined. The physical meaning and basic criterion of the envelope structure thermal reliability are formulated. The application of the thermal reliability criterion allows determining the probable variations in the thermal insulation properties during the building operation and, accordingly, the changes of the building energy performance over time.


Author(s):  
Erik M. Greensfelder ◽  
Gregor P. Henze ◽  
Vincent J. Cushing

In spite of heightened interest in anthropogenic climate change, little attention has been paid to optimizing a building’s carbon emissions at the source. Most work in building efficiency has assumed that generating plant carbon emissions are constant at their long-term average values. This study sought to improve our understanding of the temporal variations in carbon emissions on a diurnal time scale and their relation to electric system dispatch and load in order to motivate future work in optimizing building operation to reduce carbon emissions. Hourly fossil fuel plant emissions and load data, available from the EPA, were used to characterize power system performance for four US locations (IL, NY, TX, and CA). The study had set out with a hypothesis hoping to find a simple relationship between electric system load and emissions. It was found that there is a significant correlation between increased system load and decreased emissions rates, yet this correlation is not easily defined. During high load conditions, emissions reductions are related to the increased use of gas generators, or may be related to operating plants at more efficient part load ratios. The work conducted in this study shows that, while more complex than hoped for, there is indeed a strong relationship between electric system load and carbon emissions rates.


Due to manufactured technology enchantment the living being has much convenience and luxury. Though, at the same time, our current existence is doing damage to the environment. Like water pollution, air pollution and Carbon dioxide (CO2) emissions on so forth. But CO2 emissions are the one of the major reason polluting the environment. Furthermost of what we utilise in our daily life lead to emitting CO2 into the environment. Due to this it leads to global warming and climate change problems. Therefore, carbon auditing (Carbon Footprint Analysis) is the first essential step to review the use of energy, to improve energy conservation and to allow building to go green. For this reason we need carbon audit to reduce usage raw materials, waste generation so on so forth to minimise GHG emissions .“CARBON AUDIT” is conducted within the building’s boundary which includes the following stages:- People Survey to gather employee-level data, Building Survey to gather building-operation data, Carbon Footprint Analysis to evaluate the greenhouse gas (GHG) emission and Final Carbon Audit Report to provide tailored recommendations for going green along with action plan to get started