Influence of connections on the seismic behaviour of hybrid hot-rolled and cold-formed steel frames

Alloy Digest ◽  
2017 ◽  
Vol 66 (7) ◽  

Abstract Strenx Section 900 is a cold-formed steel section made of hot-rolled, high-strength steel with a minimum yield strength of 900 MPa (131 ksi). Its high strength combined with naturally stiff form enables construction of stronger and lighter structures. The common shape is a U-bend channel. This datasheet provides information on composition, physical properties, tensile properties, and bend strength as well as fracture toughness. It also includes information on forming, machining, and joining. Filing Code: SA-792. Producer or source: SSAB Swedish Steel Inc..


2011 ◽  
Vol 201-203 ◽  
pp. 2900-2903 ◽  
Author(s):  
Chui Huon Tina Ting ◽  
Hieng Ho Lau

Built-up sections are used to resist load induced in a structure when a single section is not sufficient to carry the design load for example roof trusses. In current North American Specification, the provision has been substantially taken from research in hot-rolled built-up members connected with bolts or welds [1]. The aim of this paper is to investigate on built-up back-to-back channels stub columns experimentally and theoretically using Effective Width Method and Direct Strength Method. Compression test was performed on 5 lipped channel and 5 back-to-back channels stub columns fabricated from cold-formed steel sheets of 1.2mm thicknesses. The test results indicated that local buckling is the dominant failure modes of stub columns. Therefore, Effective Width Method predicts the capacity of stub columns compared to Direct Strength Method. When compared to the average test results, results based on EWM are 5% higher while results based on DSM are 12% higher for stub column.


2017 ◽  
Vol 79 (5) ◽  
Author(s):  
Nahushananda Chakravarthy ◽  
Sivakumar Naganathan ◽  
Jonathan Tan Hsien Aun ◽  
Sreedhar Kalavagunta ◽  
Kamal Nasharuddin Mustapha ◽  
...  

Cold formed steel differ from hot rolled steel by its lesser thickness and weight. The cold formed steel applicable in roof purlin, pipe racks and wall panels etc. Due its lesser wall thickness the cold formed steel member subjected to buckling. The enhancement of load carrying capacity of the cold formed steel member can be achieved by external strengthening of CFRP. In this study cold formed channel members connected back to back to form I shaped cross section using screws. These built up beam members were 300mm, 400mm and 500mm in length with 100mm screw spacing and edge distance of 50mm were chosen for testing. CFRP fabric cut according to length, width of built up beams and wrapped outer surface of beam using epoxy resin. Experiments were carried out in two sets firstly plain built up beams and secondly CFRP wrapped beams. The test results shows that increased load carrying capacity and reduction in deflection due to CFRP strengthening. Experimental results were compared with AISI standards which are in good agreement. Experimental results shows that CFRP strengthening is economic and reliable.


2015 ◽  
Vol 74 (4) ◽  
Author(s):  
Yeong Huei Lee ◽  
Cher Siang Tan ◽  
Shahrin Mohammad ◽  
Yee Ling Lee

Connection is an important element in structural steelwork construction. Eurocode does not provide adequate design information for mechanical properties prediction of top-seat flange cleat connection, especially for thin-walled cold-formed steel structures. Adopting hot-rolled design with neglecting thin-walled behaviour could lead to unsafe or uneconomic design. This research aims to provide accurate mechanical properties prediction for bolted top-seat flange cleat connection in cold-formed steel structures. The scope of work focuses on the effect of various thickness of the flange cleat to the rotational stiffness and strength behaviour of a beam-to-column connection. Experimentally verified and validated finite element modelling technique is applied in the parametric investigation. Two categories of flange cleat thickness, ranged from 2 mm to 40 mm are studied. From the developed numerical models, it is observed that Eurocode has overestimated the initial rotational stiffness prediction, calculated with component method. The over-estimation would influence the overall stiffness of structures and force distribution within the components. As a conclusion, a set of newly proposed accurate predictions for initial rotational stiffness and strength of cold-formed steel top-seat flange cleat connection, with the influence of the thickness of flange cleat is presented.


2014 ◽  
Vol 2014 ◽  
pp. 1-11 ◽  
Author(s):  
Yeong Huei Lee ◽  
Cher Siang Tan ◽  
Shahrin Mohammad ◽  
Mahmood Md Tahir ◽  
Poi Ngian Shek

The concept of cold-formed light steel framing construction has been widespread after understanding its structural characteristics with massive research works over the years. Connection serves as one of the important elements for light steel framing in order to achieve its structural stability. Compared to hot-rolled steel sections, cold-formed steel connections perform dissimilarity due to the thin-walled behaviour. This paper aims to review current researches on cold-formed steel connections, particularly for screw connections, storage rack connections, welded connections, and bolted connections. The performance of these connections in the design of cold-formed steel structures is discussed.