Theoretical Predictions of Electro-Optic (EO) Effects in Polymer Wires

2017 ◽  
pp. 125-156
1993 ◽  
Vol 328 ◽  
Author(s):  
Grant Bourhill ◽  
Lap-Tak Cheng ◽  
Ging Lee ◽  
Seth R. Marder ◽  
Joseph W. Perry ◽  
...  

ABSTRACTA review is presented describing our recent work to correlate the first hyperpolarizability, β, of organic materials with the molecular parameter bond length alternation (BLA). Donor-acceptor polyenes displaying a wide BLA range were synthesized. For a particular chromophore, BLA was fine-tuned by varying solvent polarity. The degree of BLA was analyzed by X-ray diffraction, 1H-NMR and electronic absorption spectroscopy. Non-resonant, solvent-dependent, electric field induced second harmonic generation (EFISH) Measurements were performed to probe the variation in the second-order nonlinearity as a function of ground-state polarization. The resulting trend, which is fully consistent with theoretical predictions, identified chromophores possessing optimized positive and negative hyperpolarizabilities. An optimized chromophore was incorporated in a polymer matrix and poled. The resulting electro-optic coefficient was found to be significantly enhanced relative to the longer chromophore Disperse Red 1.


1988 ◽  
Vol 102 ◽  
pp. 41
Author(s):  
E. Silver ◽  
C. Hailey ◽  
S. Labov ◽  
N. Madden ◽  
D. Landis ◽  
...  

The merits of microcalorimetry below 1°K for high resolution spectroscopy has become widely recognized on theoretical grounds. By combining the high efficiency, broadband spectral sensitivity of traditional photoelectric detectors with the high resolution capabilities characteristic of dispersive spectrometers, the microcalorimeter could potentially revolutionize spectroscopic measurements of astrophysical and laboratory plasmas. In actuality, however, the performance of prototype instruments has fallen short of theoretical predictions and practical detectors are still unavailable for use as laboratory and space-based instruments. These issues are currently being addressed by the new collaborative initiative between LLNL, LBL, U.C.I., U.C.B., and U.C.D.. Microcalorimeters of various types are being developed and tested at temperatures of 1.4, 0.3, and 0.1°K. These include monolithic devices made from NTD Germanium and composite configurations using sapphire substrates with temperature sensors fabricated from NTD Germanium, evaporative films of Germanium-Gold alloy, or material with superconducting transition edges. A new approache to low noise pulse counting electronics has been developed that allows the ultimate speed of the device to be determined solely by the detector thermal response and geometry. Our laboratory studies of the thermal and resistive properties of these and other candidate materials should enable us to characterize the pulse shape and subsequently predict the ultimate performance. We are building a compact adiabatic demagnetization refrigerator for conveniently reaching 0.1°K in the laboratory and for use in future satellite-borne missions. A description of this instrument together with results from our most recent experiments will be presented.


Author(s):  
S. G. Ghonge ◽  
E. Goo ◽  
R. Ramesh ◽  
R. Haakenaasen ◽  
D. K. Fork

Microstructure of epitaxial ferroelectric/conductive oxide heterostructures on LaAIO3(LAO) and Si substrates have been studied by conventional and high resolution transmission electron microscopy. The epitaxial films have a wide range of potential applications in areas such as non-volatile memory devices, electro-optic devices and pyroelectric detectors. For applications such as electro-optic devices the films must be single crystal and for applications such as nonvolatile memory devices and pyroelectric devices single crystal films will enhance the performance of the devices. The ferroelectric films studied are Pb(Zr0.2Ti0.8)O3(PLZT), PbTiO3(PT), BiTiO3(BT) and Pb0.9La0.1(Zr0.2Ti0.8)0.975O3(PLZT).Electrical contact to ferroelectric films is commonly made with metals such as Pt. Metals generally have a large difference in work function compared to the work function of the ferroelectric oxides. This results in a Schottky barrier at the interface and the interfacial space charge is believed to responsible for domain pinning and degradation in the ferroelectric properties resulting in phenomenon such as fatigue.


Author(s):  
A.C. Daykin ◽  
C.J. Kiely ◽  
R.C. Pond ◽  
J.L. Batstone

When CoSi2 is grown onto a Si(111) surface it can form in two distinct orientations. A-type CoSi2 has the same orientation as the Si substrate and B-type is rotated by 180° degrees about the [111] surface normal.One method of producing epitaxial CoSi2 is to deposit Co at room temperature and anneal to 650°C.If greater than 10Å of Co is deposited then both A and B-type CoSi2 form via a number of intermediate silicides .The literature suggests that the co-existence of A and B-type CoSi2 is in some way linked to these intermediate silicides analogous to the NiSi2/Si(111) system. The phase which forms prior to complete CoSi2 formation is CoSi. This paper is a crystallographic analysis of the CoSi2/Si(l11) bicrystal using a theoretical method developed by Pond. Transmission electron microscopy (TEM) has been used to verify the theoretical predictions and to characterise the defect structure at the interface.


2020 ◽  
Vol 51 (5) ◽  
pp. 354-359 ◽  
Author(s):  
Yavor Paunov ◽  
Michaela Wänke ◽  
Tobias Vogel

Abstract. Combining the strengths of defaults and transparency information is a potentially powerful way to induce policy compliance. Despite negative theoretical predictions, a recent line of research revealed that default nudges may become more effective if people are informed why they should exhibit the targeted behavior. Yet, it is an open empirical question whether the increase in compliance came from setting a default and consequently disclosing it, or the provided information was sufficient to deliver the effect on its own. Results from an online experiment indicate that both defaulting and transparency information exert a statistically independent effect on compliance, with highest compliance rates observed in the combined condition. Practical and theoretical implications are discussed.


1997 ◽  
Vol 7 (9) ◽  
pp. 1893-1898 ◽  
Author(s):  
G. Schirripa Spagnolo ◽  
D. Ambrosini ◽  
A. Ponticiello ◽  
D. Paoletti

Sign in / Sign up

Export Citation Format

Share Document