Thin-walled sections, steel structures, steel connections, steel-concrete composite structures

2013 ◽  
Vol 95 ◽  
pp. 53-62 ◽  
Author(s):  
Diego Cárdenas ◽  
Hugo Elizalde ◽  
Piergiovanni Marzocca ◽  
Frank Abdi ◽  
Levon Minnetyan ◽  
...  

Author(s):  
Ankit Kumar

Abstract: This study examines the composite structure that is increasing commonly in developing countries. For medium-rise to high-rise building construction, RCC structures is no longer economical due to heavy dead weight, limited span, low natural frequency and hazardous formwork. The majority of commercial buildings are designed and constructed with reinforced concrete, which largely depends on the existence of the constituent materials as well as the quality of the necessary construction skills, and including the usefulness of design standards. Conventional RCC structure is not preferred nowadays for high rise structure. However, composite construction, is a recent development in the construction industry. Concrete-steel composite structures are now very popular due to some outstanding advantages over conventional concrete and steel structures. In the present work, RCC and steel-concrete composite structure are being considered for a Dynamic analysis of a G+25-storey commercial building of uniform and optimized section, located at in seismic zone IV. Response Spectrum analysis method is used to analyze RCC and composite structure, CSI ETABS v19 software is used and various results are compared such as time period, maximum storey displacement, maximum storey stiffness. Maximum storey shear and maximum stoey overturning moment. Keywords: RCC Structure, Composite Structure, Uniform Section, Optimized Section, Shear Connector, Time Period, Storey Displacement, Storey Shear, Storey Stiffness, Response Spectrum method, ETABS


1997 ◽  
Vol 1 (1) ◽  
pp. 23-37 ◽  
Author(s):  
C. Joh ◽  
W.F. Chen

The 6.8 magnitude Northridge earthquake that shook California's San Fernando Valley on January 17 in 1994, did not cause the collapse of any steel structures but connections, confidently designed and constructed in the past with traditional code simplification and common site welding techniques, were discovered not to meet our expectations. This paper reviews connection failures during the 1994 Northridge earthquake and the design philosophy and examines the post-Northridge earthquake experimental and analytical researches. Possible causes of the moment connections damage are categorized into three classes; welding-related factors, design-related factors, and material-related factors. For the analyses, the idealizations of the moment connection considering each factor are studied. From the idealization of the moment connection, the five-plate model is analyzed to investigate the stress concentration and stress state of the connection. The equivalent design crack models are investigated using the fracture mechanics approach.


Sign in / Sign up

Export Citation Format

Share Document