Estimating depth of investigation in dc resistivity and IP surveys

Geophysics ◽  
1999 ◽  
Vol 64 (2) ◽  
pp. 403-416 ◽  
Author(s):  
Douglas W. Oldenburg ◽  
Yaoguo Li

In this paper, the term “depth of investigation” refers generically to the depth below which surface data are insensitive to the value of the physical property of the earth. Estimates of this depth for dc resistivity and induced polarization (IP) surveys are essential when interpreting models obtained from any inversion because structure beneath that depth should not be interpreted geologically. We advocate carrying out a limited exploration of model space to generate a few models that have minimum structure and that differ substantially from the final model used for interpretation. Visual assessment of these models often provides answers about existence of deeper structures. Differences between the models can be quantified into a depth of investigation (DOI) index that can be displayed with the model used for interpretation. An explicit algorithm for evaluating the DOI is presented. The DOI curves are somewhat dependent upon the parameters used to generate the different models, but the results are robust enough to provide the user with a first‐order estimate of a depth region below which the earth structure is no longer constrained by the data. This prevents overinterpretation of the inversion results. The DOI analysis reaffirms the generally accepted conclusions that different electrode array geometries have different depths of penetration. However, the differences between the inverted models for different electrode arrays are far less than differences in the pseudosection images. Field data from the Century deposit are inverted and presented with their DOI index.

Geophysics ◽  
1989 ◽  
Vol 54 (8) ◽  
pp. 1031-1037 ◽  
Author(s):  
R. D. Barker

A study of collinear symmetrical four‐electrode arrays and their tripotential variations indicates the existence of an electrode array for which all the tripotential arrangements have the same depth of investigation. Examination of computer‐generated sounding curves confirms this result only when depth of investigation is defined as the median of the depth of investigation characteristic curve. The results lend support to this being the most practically useful definition of depth of investigation.


2021 ◽  
Vol 11 (9) ◽  
pp. 4144
Author(s):  
Ohad Cohen ◽  
Jean-Yves Sichel ◽  
Chanan Shaul ◽  
Itay Chen ◽  
J. Thomas Roland ◽  
...  

Although malpositioning of the cochlear implant (CI) electrode array is rare in patients with normal anatomy, when occurring it may result in reduced hearing outcome. In addition to intraoperative electrophysiologic tests, imaging is an important modality to assess correct electrode array placement. The purpose of this report was to assess the incidence and describe cases in which intraoperative plain radiographs detected a malpositioned array. Intraoperative anti-Stenver’s view plain X-rays are conducted routinely in all CI surgeries in our tertiary center before awakening the patient and breaking the sterile field. Data of patients undergoing 399 CI surgeries were retrospectively analyzed. A total of 355 had normal inner ear and temporal bone anatomy. Patients with intra or extracochlear malpositioned electrode arrays demonstrated in the intraoperative X-ray were described. There were four cases of electrode array malposition out of 355 implantations with normal anatomy (1.1%): two tip fold-overs, one extracochlear placement and one partial insertion. All electrodes were reinserted immediately; repeated radiographs were normal and the patients achieved good hearing function. Intraoperative plain anti-Stenver’s view X-rays are valuable to confirm electrode array location, allowing correction before the conclusion of surgery. These radiographs are cheaper, faster, and emit much less radiation than other imaging options, making them a viable cost-effective tool in patients with normal anatomy.


Geophysics ◽  
1994 ◽  
Vol 59 (9) ◽  
pp. 1327-1341 ◽  
Author(s):  
Douglas W. Oldenburg ◽  
Yaoguo Li

We develop three methods to invert induced polarization (IP) data. The foundation for our algorithms is an assumption that the ultimate effect of chargeability is to alter the effective conductivity when current is applied. This assumption, which was first put forth by Siegel and has been routinely adopted in the literature, permits the IP responses to be numerically modeled by carrying out two forward modelings using a DC resistivity algorithm. The intimate connection between DC and IP data means that inversion of IP data is a two‐step process. First, the DC potentials are inverted to recover a background conductivity. The distribution of chargeability can then be found by using any one of the three following techniques: (1) linearizing the IP data equation and solving a linear inverse problem, (2) manipulating the conductivities obtained after performing two DC resistivity inversions, and (3) solving a nonlinear inverse problem. Our procedure for performing the inversion is to divide the earth into rectangular prisms and to assume that the conductivity σ and chargeability η are constant in each cell. To emulate complicated earth structure we allow many cells, usually far more than there are data. The inverse problem, which has many solutions, is then solved as a problem in optimization theory. A model objective function is designed, and a “model” (either the distribution of σ or η)is sought that minimizes the objective function subject to adequately fitting the data. Generalized subspace methodologies are used to solve both inverse problems, and positivity constraints are included. The IP inversion procedures we design are generic and can be applied to 1-D, 2-D, or 3-D earth models and with any configuration of current and potential electrodes. We illustrate our methods by inverting synthetic DC/IP data taken over a 2-D earth structure and by inverting dipole‐dipole data taken in Quebec.


2007 ◽  
Vol 97 (5) ◽  
pp. 3781-3789 ◽  
Author(s):  
Ian Nauhaus ◽  
Dario L. Ringach

Recent theoretical models of primary visual cortex predict a relationship between receptive field properties and the location of the neuron within the orientation maps. Testing these predictions requires the development of new methods that allow the recording of single units at various locations across the orientation map. Here we present a novel technique for the precise alignment of functional maps and array recordings. Our strategy consists of first measuring the orientation maps in V1 using intrinsic optical imaging. A micromachined electrode array is subsequently implanted in the same patch of cortex for electrophysiological recordings, including the measurement of orientation tuning curves. The location of the array within the map is obtained by finding the position that maximizes the agreement between the preferred orientations measured electrically and optically. Experimental results of the alignment procedure from two implementations in monkey V1 are presented. The estimated accuracy of the procedure is evaluated using computer simulations. The methodology should prove useful in studying how signals from the local neighborhood of a neuron, thought to provide a dominant feedback signal, shape the receptive field properties in V1.


2002 ◽  
Vol 24 (4) ◽  
pp. 105-110 ◽  
Author(s):  
Jarbas J. R. Rohwedder ◽  
Celio Pasquini ◽  
Ivo M. Raimundo, Jr. ◽  
M. Conceiçao ◽  
B. S. M. Montenegro ◽  
...  

A versatile potentiometer that works with electrode arrays in flow injection and/or monosegmented flow systems is described. The potentiometer is controlled by a microcomputer that allows individual, sequential multiplexed or random accesses to eight electrodes while employing only one reference electrode. The instrument was demonstrated by monitoring an array of seven flow-through ion-selective electrodes for Ag+and for three electrodes for Cl-, Ca2+and K+. The figures of merit of the individual and multiplexed (summed) readings of the electrode array were compared. The absolute standard deviation of the measurements made by summing the potential of two or more electrodes was maintained constant, thus improving the precision of the measurements. This result shows that an attempt to combine the signals of the electrodes to produce a more intense signal in the Hadamard strategy is feasible and accompanied by a proportional improvement in the precision of individual measurements. The preliminary tests suggest that the system can allow for 270 determinations per hour, with a linear range from1.0×10−2to1.0×10−4mol l-1for the three di¡erent analytes. Detection limits were estimated as3.1×10−5,3.0×10−6and1.0×10−5mol l-1for Cl-, Ca2+and K+, respectively.


2017 ◽  
Vol 9 (1) ◽  
Author(s):  
Amin Amini ◽  
Hamidreza Ramazi

AbstractThis paper is devoted to the application of the Combined Resistivity Sounding and Profiling electrode configuration (CRSP) to detect underground cavities. Electrical resistivity surveying is among the most favorite geophysical methods due to its nondestructive and economical properties in a wide range of geosciences. Several types of the electrode arrays are applied to detect different certain objectives. In one hand, the electrode array plays an important role in determination of output resolution and depth of investigations in all resistivity surveys. On the other hand, they have their own merits and demerits in terms of depth of investigations, signal strength, and sensitivity to resistivity variations. In this article several synthetic models, simulating different conditions of cavity occurrence, were used to examine the responses of some conventional electrode arrays and also CRSP array. The results showed that CRSP electrode configuration can detect the desired objectives with a higher resolution rather than some other types of arrays. Also a field case study was discussed in which electrical resistivity approach was conducted in Abshenasan expressway (Tehran, Iran) U-turn bridge site for detecting potential cavities and/or filling loose materials. The results led to detect an aqueduct tunnel passing beneath the study area.


Geophysics ◽  
1978 ◽  
Vol 43 (3) ◽  
pp. 610-625 ◽  
Author(s):  
D. W. Oldenburg

The linearized inverse theory of Backus and Gilbert has been used to invert potential difference measurements obtained from direct current resistivity soundings. The resistivity is assumed to be a continuous function of depth, hence many of the difficulties encountered when assuming that the earth is a layered half‐space are avoided. An iterative technique is used to construct a resistivity model whose calculated responses agree with the observations, and the model is then appraised to find those features which are uniquely determined by the surface observations. Also, the existence of the Fréchet kernels allows direct comparisons of the resolution provided by various electrode geometries and thus the design of electrode arrays to enhance resolution becomes more feasible.


2017 ◽  
Vol 132 (3) ◽  
pp. 224-229 ◽  
Author(s):  
P Mittmann ◽  
A Ernst ◽  
I Todt

AbstractBackground:Preservation of residual hearing is one of the major goals in modern cochlear implant surgery. Intra-cochlear fluid pressure changes influence residual hearing, and should be kept low before, during and after cochlear implant insertion.Methods:Experiments were performed in an artificial cochlear model. A pressure sensor was inserted in the apical part. Five insertions were performed on two electrode arrays. Each insertion was divided into three parts, and statistically evaluated in terms of pressure peak frequency and pressure peak amplitude.Results:The peak frequency over each third part of the electrode increased in both electrode arrays. A slight increase was seen in peak amplitude in the lateral wall electrode array, but not in the midscalar electrode array. Significant differences were found in the first third of both electrode arrays.Conclusion:The midscalar and lateral wall electrode arrays have different intra-cochlear fluid pressure changes associated with intra-cochlear placement, electrode characteristics and insertion.


2014 ◽  
Vol 5 (1) ◽  
Author(s):  
Dong-Wook Park ◽  
Amelia A. Schendel ◽  
Solomon Mikael ◽  
Sarah K. Brodnick ◽  
Thomas J. Richner ◽  
...  

Abstract Neural micro-electrode arrays that are transparent over a broad wavelength spectrum from ultraviolet to infrared could allow for simultaneous electrophysiology and optical imaging, as well as optogenetic modulation of the underlying brain tissue. The long-term biocompatibility and reliability of neural micro-electrodes also require their mechanical flexibility and compliance with soft tissues. Here we present a graphene-based, carbon-layered electrode array (CLEAR) device, which can be implanted on the brain surface in rodents for high-resolution neurophysiological recording. We characterize optical transparency of the device at >90% transmission over the ultraviolet to infrared spectrum and demonstrate its utility through optical interface experiments that use this broad spectrum transparency. These include optogenetic activation of focal cortical areas directly beneath electrodes, in vivo imaging of the cortical vasculature via fluorescence microscopy and 3D optical coherence tomography. This study demonstrates an array of interfacing abilities of the CLEAR device and its utility for neural applications.


2011 ◽  
Vol 254 ◽  
pp. 82-85 ◽  
Author(s):  
Nishant S. Lawand ◽  
P.J. French ◽  
Jeroen J. Briaire ◽  
Johan H.M. Frijns

Cochlear Implant's (CI's) are devices that provides sense of sound to people who are deaf or severely hard of hearing. The important issue with CI's is the electrode design and its placement. The array should be placed close to the modiolar wall of cochlea to stimulate the auditory neurons in accordance with the frequency of the sound and the tonotopic organization of cochlea. It should be flexible for easy surgical insertion and biocompatible enough to withstand the hostile and saline warm environment inside the cochlea. Silicon semiconductor micro-fabrication is an promising technology for advanced CI electrode arrays which will replace the traditional fabrication method. In this paper the design for the silicon electrode array with its consideration is shown. Preliminary simulation results for a stiff probe puncturing the cochlear auditory nerve, which is done to get the stimulation pattern and to realise the mechanical strength of the stiff probe.