scholarly journals Electrical impedance tomography to monitor regional tidal ventilation at different pressure support levels

Critical Care ◽  
2011 ◽  
Vol 15 (S1) ◽  
Author(s):  
T Mauri ◽  
G Bellani ◽  
A Confalonieri ◽  
P Tagliabue ◽  
M Bombino ◽  
...  
2012 ◽  
Vol 116 (6) ◽  
pp. 1227-1234 ◽  
Author(s):  
Oliver C. Radke ◽  
Thomas Schneider ◽  
Axel R. Heller ◽  
Thea Koch

Background Positive-pressure ventilation causes a ventral redistribution of ventilation. Spontaneous breathing during general anesthesia with a laryngeal mask airway could prevent this redistribution of ventilation. We hypothesize that, compared with pressure-controlled ventilation, spontaneous breathing and pressure support ventilation reduce the extent of the redistribution of ventilation as detected by electrical impedance tomography. Methods The study was a randomized, three-armed, observational, clinical trial without blinding. With approval from the local ethics committee, we enrolled 30 nonobese patients without severe cardiac or pulmonary comorbidities who were scheduled for elective orthopedic surgery. All of the procedures were performed under general anesthesia with a laryngeal mask airway and a standardized anesthetic regimen. The center of ventilation (primary outcome) was calculated before the induction of anesthesia (AWAKE), after the placement of the laryngeal mask airway (BEGIN), before the end of anesthesia (END), and after arrival in the postanesthesia care unit (PACU). Results The center of ventilation during anesthesia (BEGIN) was higher than baseline (AWAKE) in both the pressure-controlled and pressure support ventilation groups (pressure control: 55.0 vs. 48.3, pressure support: 54.7 vs. 48.8, respectively; multivariate analysis of covariance, P < 0.01), whereas the values in the spontaneous breathing group remained at baseline levels (47.9 vs. 48.5). In the postanesthesia care unit, the center of ventilation had returned to the baseline values in all groups. No adverse events were recorded. Conclusions Both pressure-controlled ventilation and pressure support ventilation induce a redistribution of ventilation toward the ventral region, as detected by electrical impedance tomography. Spontaneous breathing prevents this redistribution.


2018 ◽  
Vol 51 (2) ◽  
pp. 222-226 ◽  
Author(s):  
M. Mosing ◽  
A. D. Waldmann ◽  
A. Raisis ◽  
S. H. Böhm ◽  
E. Drynan ◽  
...  

Author(s):  
Bruno Furtado de Moura ◽  
francisco sepulveda ◽  
Jorge Luis Jorge Acevedo ◽  
Wellington Betencurte da Silva ◽  
Rogerio Ramos ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document