Exploring the Optical Properties of Picture Varnishes Using Imaging Techniques

2003 ◽  
Vol 48 (2) ◽  
pp. 73-82 ◽  
Author(s):  
Roy S.Berns ◽  
E. René de la Rie
Author(s):  
Barbara Cisterna ◽  
Federico Boschi ◽  
Anna Cleta Croce ◽  
Rachele Podda ◽  
Serena Zanzoni ◽  
...  

Optical Imaging (OI) is an emerging field developed in recent years which can be a very versatile, fast and non-invasive approach for the acquisition of images of  small (few centimetres) sized samples, such as layers of cells (in vitro), small animals (in vivo), animal organs (ex vivo) and innovative materials. OI was primarily developed for biomedical applications to study the progression of some pathologies and to assess the efficacy of new pharmaceutical compounds. Here we applied the OI technique to a completely new field: the study of food optical properties. In this case we exploited the optical properties of endogenous molecules, which are generally considered responsible of a background noise affecting the investigation. Here we used this sort of “noise”, named autofluorescence, to obtain information on the drying of Corvinone grapes employed for Amarone wine production. OI can provide interesting information and, inserted in a multimodal approach, it may be a real support to other techniques in the description of a biological phenomenon.


Author(s):  
Domenica Marabello ◽  
Paola Antoniotti ◽  
Paola Benzi ◽  
Fabio Beccari ◽  
Carlo Canepa ◽  
...  

In the last few decades optical imaging techniques based on nonlinear optical properties have been of interest for biosensing applications. This work focuses on two isostructural and isomorphous sugar-derived metal–organic frameworks (MOFs) with second-harmonic generation (SHG) properties, in order to investigate their possible application as biosensors in view of their high biocompatibility. Combining 2-deoxy-D-galactose with the metal halogenides CaX 2 (X = Br, I), two new isomorphous MOFs of formula [Ca(C6H12O5)2]X 2 were obtained and characterized through single-crystal X-ray diffraction. The first-order static hyperpolarizability and second-order susceptibility were estimated by in vacuo and in-crystal density functional theory calculations, and compared with the experimental SHG response of powdered samples. The parameters influencing the SHG response of these compounds were investigated by comparison with similar previously analysed MOFs, to understand how to design more efficient materials to be used as nanoprobes by exploiting crystal engineering techniques.


2020 ◽  
Vol 10 (21) ◽  
pp. 7661
Author(s):  
Andrea Doria ◽  
Gian Piero Gallerano ◽  
Emilio Giovenale ◽  
Luca Senni ◽  
Manuel Greco ◽  
...  

In recent years, THz imaging techniques have been used in several fields of application. At the beginning of the century, the low availability of powerful THz sources was one of the limiting factors to the advancement of THz technology. At the ENEA center in Frascati, two Free Electron Lasers (FELs) operating in the THz spectral region were available at that time, making it possible to exploit all the features of THz imaging. In this paper, we will describe an alternative THz imaging technique, developed over 15 years of studies at the ENEA center of Frascati, and its application in the art conservation field, reporting the latest results of such studies on the optical properties of pigments in the GHz-THz region of the spectrum, on the possibility of detecting biological weeds under mosaic tiles and on the THz analysis of ancient leather wallpapers. This alternative technique was first developed in the framework of a bilateral collaboration between Japan and Italy, the THz-ARTE Project, which involved NICT (Tokyo), NNRICP (Nara), ENEA (Frascati) and IFAC-CNR (Florence). Most of the THz imaging techniques at that time were based on THz-Time Domain (THz-TD) devices. In the paper will be described how this alternative technique is able to measure the phase of the reflected radiation, thus providing information on the optical properties of the materials under study, such as mural paintings and mosaics. This makes it possible to detect the presence of hidden artworks, additional elements under paint layers, and dielectric materials. To describe the potential and the limits of this alternative imaging technique we will start from a description of the first THz imaging setup at the ENEA center of Frascati, based upon a THz Free Electron Laser. A description of the theoretical principle underlying this technique will be given. The first results in the field of art conservation are summarized, while the new results of a systematic study on the optical properties of pigments are reported and the realization of a portable THz imaging device, and its application “on site” for the analysis of frescoes are shown. The success of this prototype lead to the identification of different types of artworks as possible targets to be studied. New results about the ability of detecting water, and possibly the water content of biological weeds, under mosaic tiles are described, while new experimental measurements on Leather Wallpapers, both “in situ” and in a laboratory environment, are discussed later. A final analysis on the pro and the cons of this alternative imaging technique and on its possible utilization with the developed prototype is carried out together with the considerations on possible future developments and its potential use as an extension of other imaging techniques.


2008 ◽  
Vol 2008 ◽  
pp. 1-8 ◽  
Author(s):  
Elina A. Genina ◽  
Alexey N. Bashkatov ◽  
Valery V. Tuchin

We present experimental results on optical properties of cranial bone controlled by administration of propylene glycol and glycerol. Both transmittance and reflectance spectra of human and porcine cranial bone in vitro were measured. For estimation of absorption and reduced scattering coefficients of the bone, the inverse adding-doubling method was used. The decrease of reflectance of the samples under action of the immersion agents was demonstrated. The experiments have shown that administration of the immersion liquids allows for effective controlling of tissue optical characteristics that makes bone more transparent, thereby increasing the ability of light penetration through the tissue. The presented results can be used in developing of functional imaging techniques, including OCT.


Author(s):  
K. Tsuno ◽  
T. Honda ◽  
Y. Harada ◽  
M. Naruse

Developement of computer technology provides much improvements on electron microscopy, such as simulation of images, reconstruction of images and automatic controll of microscopes (auto-focussing and auto-correction of astigmatism) and design of electron microscope lenses by using a finite element method (FEM). In this investigation, procedures for simulating the optical properties of objective lenses of HREM and the characteristics of the new lens for HREM at 200 kV are described.The process for designing the objective lens is divided into three stages. Stage 1 is the process for estimating the optical properties of the lens. Firstly, calculation by FEM is made for simulating the axial magnetic field distributions Bzc of the lens. Secondly, electron ray trajectory is numerically calculated by using Bzc. And lastly, using Bzc and ray trajectory, spherical and chromatic aberration coefficients Cs and Cc are numerically calculated. Above calculations are repeated by changing the shape of lens until! to find an optimum aberration coefficients.


Author(s):  
Jerome J. Paulin

Within the past decade it has become apparent that HVEM offers the biologist a means to explore the three-dimensional structure of cells and/or organelles. Stereo-imaging of thick sections (e.g. 0.25-10 μm) not only reveals anatomical features of cellular components, but also reduces errors of interpretation associated with overlap of structures seen in thick sections. Concomitant with stereo-imaging techniques conventional serial Sectioning methods developed with thin sections have been adopted to serial thick sections (≥ 0.25 μm). Three-dimensional reconstructions of the chondriome of several species of trypanosomatid flagellates have been made from tracings of mitochondrial profiles on cellulose acetate sheets. The sheets are flooded with acetone, gluing them together, and the model sawed from the composite and redrawn.The extensive mitochondrial reticulum can be seen in consecutive thick sections of (0.25 μm thick) Crithidia fasciculata (Figs. 1-2). Profiles of the mitochondrion are distinguishable from the anterior apex of the cell (small arrow, Fig. 1) to the posterior pole (small arrow, Fig. 2).


Author(s):  
A. Strojnik ◽  
J.W. Scholl ◽  
V. Bevc

The electron accelerator, as inserted between the electron source (injector) and the imaging column of the HVEM, is usually a strong lens and should be optimized in order to ensure high brightness over a wide range of accelerating voltages and illuminating conditions. This is especially true in the case of the STEM where the brightness directly determines the highest resolution attainable. In the past, the optical behavior of accelerators was usually determined for a particular configuration. During the development of the accelerator for the Arizona 1 MEV STEM, systematic investigation was made of the major optical properties for a variety of electrode configurations, number of stages N, accelerating voltages, 1 and 10 MEV, and a range of injection voltages ϕ0 = 1, 3, 10, 30, 100, 300 kV).


Author(s):  
Marcos F. Maestre

Recently we have developed a form of polarization microscopy that forms images using optical properties that have previously been limited to macroscopic samples. This has given us a new window into the distribution of structure on a microscopic scale. We have coined the name differential polarization microscopy to identify the images obtained that are due to certain polarization dependent effects. Differential polarization microscopy has its origins in various spectroscopic techniques that have been used to study longer range structures in solution as well as solids. The differential scattering of circularly polarized light has been shown to be dependent on the long range chiral order, both theoretically and experimentally. The same theoretical approach was used to show that images due to differential scattering of circularly polarized light will give images dependent on chiral structures. With large helices (greater than the wavelength of light) the pitch and radius of the helix could be measured directly from these images.


Author(s):  
S. R. Herd ◽  
P. Chaudhari

Electron diffraction and direct transmission have been used extensively to study the local atomic arrangement in amorphous solids and in particular Ge. Nearest neighbor distances had been calculated from E.D. profiles and the results have been interpreted in terms of the microcrystalline or the random network models. Direct transmission electron microscopy appears the most direct and accurate method to resolve this issue since the spacial resolution of the better instruments are of the order of 3Å. In particular the tilted beam interference method is used regularly to show fringes corresponding to 1.5 to 3Å lattice planes in crystals as resolution tests.


Author(s):  
Shawn Williams ◽  
Xiaodong Zhang ◽  
Susan Lamm ◽  
Jack Van’t Hof

The Scanning Transmission X-ray Microscope (STXM) is well suited for investigating metaphase chromosome structure. The absorption cross-section of soft x-rays having energies between the carbon and oxygen K edges (284 - 531 eV) is 6 - 9.5 times greater for organic specimens than for water, which permits one to examine unstained, wet biological specimens with resolution superior to that attainable using visible light. The attenuation length of the x-rays is suitable for imaging micron thick specimens without sectioning. This large difference in cross-section yields good specimen contrast, so that fewer soft x-rays than electrons are required to image wet biological specimens at a given resolution. But most imaging techniques delivering better resolution than visible light produce radiation damage. Soft x-rays are known to be very effective in damaging biological specimens. The STXM is constructed to minimize specimen dose, but it is important to measure the actual damage induced as a function of dose in order to determine the dose range within which radiation damage does not compromise image quality.


Sign in / Sign up

Export Citation Format

Share Document