High-frequency operation of pulsatile ventricular assist devices: A computational study on circular and elliptically shaped pumps

2019 ◽  
Vol 42 (12) ◽  
pp. 725-734 ◽  
Author(s):  
Christian Loosli ◽  
Stephan Rupp ◽  
Bente Thamsen ◽  
Mathias Rebholz ◽  
Gerald Kress ◽  
...  

Pulsatile positive displacement pumps as ventricular assist devices were gradually replaced by rotary devices due to their large volume and high adverse event rates. Nevertheless, pulsatile ventricular assist devices might be beneficial with regard to gastrointestinal bleeding and cardiac recovery. Therefore, aim of this study was to investigate the flow field in new pulsatile ventricular assist devices concepts with an increased pump frequency, which would allow lower stroke volumes to reduce the pump size. We developed a novel elliptically shaped pulsatile ventricular assist devices, which we compared to a design based on a circular shape. The pump size was adjusted to deliver similar flow rates at pump frequencies of 80, 160, and 240 bpm. Through a computational fluid dynamics study, we investigated flow patterns, residence times, and wall shear stresses for different frequencies and pump sizes. A pump size reduction by almost 50% is possible when using a threefold pump frequency. We show that flow patterns inside the circular pump are frequency dependent, while they remain similar for the elliptic pump. With slightly increased wall shear stresses for higher frequencies, maximum wall shear stresses on the pump housing are higher for the circular design (42.2 Pa vs 18.4 Pa). The calculated blood residence times within the pump decrease significantly with increasing pump rates. A smaller pump size leads to a slight increase of wall shear stresses and a significant improvement of residence times. Hence, high-frequency operation of pulsatile ventricular assist devices, especially in combination with an elliptical shape, might be a feasible mean to reduce the size, without any expectable disadvantages in terms of hemocompatibility.

2012 ◽  
Vol 134 (8) ◽  
Author(s):  
Katharine H. Fraser ◽  
Tao Zhang ◽  
M. Ertan Taskin ◽  
Bartley P. Griffith ◽  
Zhongjun J. Wu

Ventricular assist devices (VADs) have already helped many patients with heart failure but have the potential to assist more patients if current problems with blood damage (hemolysis, platelet activation, thrombosis and emboli, and destruction of the von Willebrand factor (vWf)) can be eliminated. A step towards this goal is better understanding of the relationships between shear stress, exposure time, and blood damage and, from there, the development of numerical models for the different types of blood damage to enable the design of improved VADs. In this study, computational fluid dynamics (CFD) was used to calculate the hemodynamics in three clinical VADs and two investigational VADs and the shear stress, residence time, and hemolysis were investigated. A new scalar transport model for hemolysis was developed. The results were compared with in vitro measurements of the pressure head in each VAD and the hemolysis index in two VADs. A comparative analysis of the blood damage related fluid dynamic parameters and hemolysis index was performed among the VADs. Compared to the centrifugal VADs, the axial VADs had: higher mean scalar shear stress (sss); a wider range of sss, with larger maxima and larger percentage volumes at both low and high sss; and longer residence times at very high sss. The hemolysis predictions were in agreement with the experiments and showed that the axial VADs had a higher hemolysis index. The increased hemolysis in axial VADs compared to centrifugal VADs is a direct result of their higher shear stresses and longer residence times. Since platelet activation and destruction of the vWf also require high shear stresses, the flow conditions inside axial VADs are likely to result in more of these types of blood damage compared with centrifugal VADs.


ASAIO Journal ◽  
2020 ◽  
Vol 67 (1) ◽  
pp. 74-83
Author(s):  
Lorenzo Rossini ◽  
Oscar Ö. Braun ◽  
Michela Brambatti ◽  
Yolanda Benito ◽  
Adam Mizeracki ◽  
...  

Blood ◽  
2015 ◽  
Vol 126 (23) ◽  
pp. 1115-1115
Author(s):  
Tania Torres ◽  
Jeanine M. Walenga ◽  
Bryan Menapace ◽  
Erin Coglianese ◽  
Walter Jeske ◽  
...  

Abstract Introduction: Ventricular assist devices (VADs) are increasingly being used in the clinical management of patients with heart failure. While effective, there are risks associated with the use of a VAD. One of the most serious risks is pump thrombosis characterized by an organized fibrin deposition in the pump, which requires clinical intervention and/or surgical replacement of the device. Due to the growing number of cardiac patients with an implanted VAD, it is important to understand the susceptibility to hemostatic dysregulation among these patients to prevent complications. In current clinical practice VAD pump thrombosis is detected through an elevation in plasma lactate dehydrogenase levels [LDH; >2x upper limit of normal (ULN)]. However, this method of detection is limited by an inability to detect a pump thrombus before it becomes clinically significant. Cellular microparticles (MPs) are submicron membrane-derived exocytotic vesicles that are derived from a variety of cell types by outward blebbing of the plasma membrane in response to activation stimuli. Blood cell-derived MPs can form in response to hemostatic activation, inflammation and altered rheology. The aim of this study was to determine whether levels of cellular MPs can be used more effectively than clinical parameters to predict thrombotic events in VAD patients. Methods: Blood samples were collected peri-operatively and long-term post-operatively (until transplant or expiration) during normal clinic visits from 13 consented patients who were implanted with a HeartMate II LVAD (Thoratec, Pleasanton, CA). Fresh whole blood collected in 3.2% sodium citrate was centrifuged for platelet poor plasma then ultracentrifuged (20,000 g, 90 min) to pellet MPs. Aliquots of the MP rich samples were stained with the dye PKH67 (to identify biological membranes) then separated into five tubes containing either: Tyrode's buffer (control), CD41-PE (platelets), CD45-PE [leukocytes (WBC]), CD146-PE [endothelium (EC)], or CD235-PE [erythrocytes (RBCs)]. Samples were analyzed on an EPICS XL flow cytometer (Beckman-Coulter, Miami, FL) to determine the presence and quantity of cellular MPs using an in-house assay. MPs were identified as PKH67(+) events with a size < 1µm based on size-defined polystyrene beads. Blood samples from 12 healthy individuals were processed in the same manner to establish normal MP levels. A database of clinical events in the LVAD patients was created from medical chart review and included LDH, platelet count, aPTT, D-dimer, fibrinogen and assessment of warfarin by INR. For each patient, clinical and MP data were graphed on a linear time scale; the day that the MP and the clinical values exceeded their ULN was identified and related to time of a clinical adverse event. Results: MP levels in patients without adverse events during the follow-up period (2/13) remained below the ULN of 500 microparticles. Patients with thrombotic episodes (11/13) had elevated levels (2000 to 9000 microparticles) a median 50 days (range 35-391 days) prior to LDH elevation; MP levels reverted to normal following resolution of the event. Platelet and RBC MPs were elevated earlier and to a greater extent than MPs from WBCs and ECs. Some patients (2/11) only had an elevation of RBC MPs. Platelet counts were elevated up to 50 days post-surgery (12/13 patients), but levels were normal at time of the thrombotic event. There was no obvious association with adverse events for INR time out of therapeutic range or any other clinical parameter. Discussion: Microparticle levels in VAD patients with thrombotic events were shown to cross the normal threshold weeks prior to the time when common clinical parameters indicated an abnormality, suggesting that changes in microparticle levels may be useful in predicting thrombotic events. Hypercoagulability in VAD patients can be influenced by a number of factors including exposure of blood to foreign surfaces, altered shear stresses, inflammation and infection. Data from this investigation warrants further study for the incorporation of microparticles into the clinical management of patients with implanted VADs and to determine whether the pattern of change in microparticle subtypes can identify the stimulus for pump thrombosis, leading to more effective prophylactic measures. Disclosures No relevant conflicts of interest to declare.


2017 ◽  
Vol 39 ◽  
pp. 182-188 ◽  
Author(s):  
Loay S. Kabbani ◽  
Semeret Munie ◽  
Judith Lin ◽  
Mauricio Velez ◽  
Iyad Isseh ◽  
...  

2018 ◽  
Vol 41 (11) ◽  
pp. 738-751 ◽  
Author(s):  
Dominica PY Khoo ◽  
Andrew N Cookson ◽  
Harinderjit S Gill ◽  
Katharine H Fraser

Despite the evolution of ventricular assist devices, ventricular assist device patients still suffer from complications due to the damage to blood by fluid dynamic stress. Since rotary ventricular assist devices are assumed to exert mainly shear stress, studies of blood damage are based on shear flow experiments. However, measurements and simulations of cell and protein deformation show normal and shear stresses deform, and potentially damage, cells and proteins differently. The aim was to use computational fluid dynamics to assess the prevalence of normal stress, in comparison with shear stress, in rotary ventricular assist devices. Our calculations showed normal stresses do occur in rotary ventricular assist devices: the fluid volumes experiencing normal stress above 10 Pa were 0.011 mL (0.092%) and 0.027 mL (0.39%) for the HeartWare HVAD and HeartMate II (HMII), and normal stresses over 100 Pa were present. However, the shear stress volumes were up to two orders of magnitude larger than the normal stress volumes. Considering thresholds for red blood cell and von Willebrand factor deformation by normal and shear stresses, the fluid volumes causing deformation by normal stress were between 2.5 and 5 times the size of those causing deformation by shear stress. The exposure times to the individual normal stress deformation regions were around 1 ms. The results clearly show, for the first time, that while blood within rotary ventricular assist devices experiences more shear stress at much higher magnitudes as compared with normal stress, there is sufficient normal stress exposure present to cause deformation of, and potentially damage to, the blood components. This study is the first to quantify the fluid stress components in real blood contacting devices.