scholarly journals Valve-in-Valve Implantation of Medtronic CoreValve Prosthesis in Patients with Failing Bioprosthetic Aortic Valves

2012 ◽  
Vol 5 (5) ◽  
pp. 689-697 ◽  
Author(s):  
Axel Linke ◽  
Felix Woitek ◽  
Marc W. Merx ◽  
Conrad Schiefer ◽  
Sven Möbius-Winkler ◽  
...  
2020 ◽  
Vol 7 (12) ◽  
pp. 201838
Author(s):  
Romina Plitman Mayo ◽  
Halit Yaakobovich ◽  
Ariel Finkelstein ◽  
Shawn C. Shadden ◽  
Gil Marom

Leaflet thrombosis has been suggested as the reason for the reduced leaflet motion in cases of hypoattenuated leaflet thickening of bioprosthetic aortic valves. This work aimed to estimate the risk of leaflet thrombosis in two post-valve-in-valve (ViV) configurations, using five different numerical approaches. Realistic ViV configurations were calculated by modelling the deployments of the latest version of transcatheter aortic valve devices (Medtronic Evolut PRO, Edwards SAPIEN 3) in the surgical Sorin Mitroflow. Computational fluid dynamics simulations of blood flow followed the dry models. Lagrangian and Eulerian measures of near-wall stagnation were implemented by particle and concentration tracking, respectively, to estimate the thrombogenicity and to predict the risk locations. Most of the numerical approaches indicate a higher leaflet thrombosis risk in the Edwards SAPIEN 3 device because of its intra-annular implantation. The Eulerian approaches estimated high-risk locations in agreement with the wall sheer stress (WSS) separation points. On the other hand, the Lagrangian approaches predicted high-risk locations at the proximal regions of the leaflets matching the low WSS magnitude regions of both transcatheter aortic valve implantation models and reported clinical and experimental data. The proposed methods can help optimizing future designs of transcatheter aortic valves with minimal thrombotic risks.


2012 ◽  
Vol 5 (5) ◽  
pp. 571-577 ◽  
Author(s):  
Stefan Toggweiler ◽  
David A. Wood ◽  
Josep Rodés-Cabau ◽  
Samir Kapadia ◽  
Alexander B. Willson ◽  
...  

2020 ◽  
Vol 21 (Supplement_1) ◽  
Author(s):  
S Muscoli ◽  
V Cammalleri ◽  
J Cosma ◽  
M Zuccaro ◽  
M Macrini ◽  
...  

Abstract BACKGROUND Early structural valve deterioration (SVD) frequently occurs in Mitroflow aortic bioprosthesis, especially for small sizes (19-mm and 21-mm), and it is associated with reduced overall survival. Treatment by percutaneous valve-in-valve (ViV) implantation is considered a challenging procedure. This is mainly due to an elevated risk of coronary ostia obstruction and high residual post-procedural mean gradients (mG), particularly when severe pre-existing patient-prosthesis mismatch (PPM) is present. PURPOSE Aim of our study was to assess the feasibility of transfemoral ViV in small Mitroflow aortic valves using supra-annular self-expanding valves, named CoreValve and Evolut R and Acurate neo and report the midterm clinical results by comparing serum natriuretic peptide type B levels (BNP) before the procedure and at a mean follow-up of 2 years. METHODS This is an observational study including 11 patients with stenotic-type SVD of small Mitroflow aortic valves, considered at high/prohibitive risk for surgical reoperation, who underwent ViV implantation between July 2012 and March 2018. We performed echocardiographic assessment of valve hemodynamics (according to VARC-2 definitions) before and after the procedure and during the follow-up. We used the BNP ratio (the ratio between measured serum BNP/NT-proBNP level and maximal normal level) to compare BNP results before the procedure and at follow-up. All-cause mortality during the hospitalization and follow-up was also reported. RESULTS The Mitroflow size was 19-mm in 4 patients and 21-mm in 7 patients. Pre-existing severe PPM was present in 4 patients and moderate PPM in 7. CoreValve 26 was implanted in 2 patients, EvolutR 23 in 5 and Acurate neo S in 4 patients. We reported no coronary obstruction, deaths or other major events during the hospitalization. At a mean follow-up of 2 years one patient died. The baseline aortic mG of 56 ± 19 mmHg has significantly reduced after the procedure to 16,6 ± 8 mmHg (p < 0.0001) and follow-up 29,6 ± 16 mmHg (p = 0.008). A post-procedural mG≥20, but <40 mmHg, was observed in 3 patients. BNP ratio at baseline was 14,6 ± 12; only one patient had a BNP ratio <3. At follow-up (n = 7 patients), BNP ratio was significantly lowered to 1,5 ± 1,08 (p = 0.01) with only one patient with a BNP ratio >3. Patients with mPG ≥20 mmHg did not show differences in terms of mortality and reduction of serum BNP levels. CONCLUSIONS In our experience the ViV procedure on small degenerated aortic Mitroflow bioprosthesis appears to be technically feasible and provides good midterm clinical results with a net reduction in serum BNP levels, although an increase in mG was observed. Even though a post-procedural mG ≥20 mmHg is considered indicative of suboptimal aortic valve hemodynamics (according to VARC-2 criteria), its correlation with worse outcomes remains unclear and deserves further investigations.


2011 ◽  
Vol 27 (5) ◽  
pp. S113
Author(s):  
D.A. Wood ◽  
S. Toggweiler ◽  
J. Ye ◽  
A. Cheung ◽  
J. Leipsic ◽  
...  

Author(s):  
Abdelrahman I. Abushouk ◽  
Omar Abdelfattah ◽  
Anas Saad ◽  
Toshiaki Isogai ◽  
Shashank Shekhar ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document