The Use of Free Fat Tissue Transfer from the Buccal Fat Pad to Obtain and Maintain Primary Closure and to Improve Soft Tissue Thickness at Bone-Augmented Sites: Technique Presentation and Report of Case Series

2014 ◽  
Vol 29 (2) ◽  
pp. e220-e231 ◽  
Author(s):  
Fares Kablan ◽  
Zvi Laster
PLoS ONE ◽  
2021 ◽  
Vol 16 (9) ◽  
pp. e0257790
Author(s):  
Troy Morrison ◽  
Sara Jones ◽  
Ryan Scott Causby ◽  
Kerry Thoirs

Ultrasound can be used to assess injury and structural changes to the soft-tissue structure of the foot. It may be useful to assess the feet of people with diabetes who are at increased risk of plantar soft-tissue pathological changes. The aim of this study was to determine if ultrasound measurements of plantar soft-tissue thickness and assessments of tissue acoustic characteristics are reliable in people with and without diabetes mellitus. A repeated measures design was used to determine intra-observer reliability for ultrasound measurements of plantar skin and fat pad thickness and intra- and inter-observer reliability of plantar skin and fat pad tissue characterisation assessments made at foot sites which are at risk of tissue injury in people with diabetes. Thickness measurements and tissue characterisation assessments were obtained at the heel and forefoot in both the unloaded and compressed states and included discrete layers of the plantar tissues: skin, microchamber, horizontal fibrous band, macrochamber and total soft-tissue depth. At each site, relative intra-observer reliability was achieved for the measurement of at least one plantar tissue layer. The total soft-tissue thickness measured in the unloaded state (ICC 0.925–0.976) demonstrated intra-observer reliability and is the most sensitive for detecting small change on repeated measures. Intra-observer agreement was demonstrated for tissue characteristic assessments of the skin at the heel (k = 0.70), fat pad at the lateral sesamoid region (k = 0.70) and both skin and fat pad at the second (k = 0.80, k = 0.70 respectively) and third metatarsal heads (k = 0.90, k = 0.79 respectively). However, acceptable inter-observer agreement was not demonstrated for any tissue characteristic assessment, therefore the use of multiple observers should be avoided when making these assessments.


2019 ◽  
Vol 23 (3) ◽  
pp. 297-302 ◽  
Author(s):  
Julia D. Sharma ◽  
Kiran K. Seunarine ◽  
Muhammad Zubair Tahir ◽  
Martin M. Tisdall

OBJECTIVEThe aim of this study was to compare the accuracy of optical frameless neuronavigation (ON) and robot-assisted (RA) stereoelectroencephalography (SEEG) electrode placement in children, and to identify factors that might increase the risk of misplacement.METHODSThe authors undertook a retrospective review of all children who underwent SEEG at their institution. Twenty children were identified who underwent stereotactic placement of a total of 218 electrodes. Six procedures were performed using ON and 14 were placed using a robotic assistant. Placement error was calculated at cortical entry and at the target by calculating the Euclidean distance between the electrode and the planned cortical entry and target points. The Mann-Whitney U-test was used to compare the results for ON and RA placement accuracy. For each electrode placed using robotic assistance, extracranial soft-tissue thickness, bone thickness, and intracranial length were measured. Entry angle of electrode to bone was calculated using stereotactic coordinates. A stepwise linear regression model was used to test for variables that significantly influenced placement error.RESULTSBetween 8 and 17 electrodes (median 10 electrodes) were placed per patient. Median target point localization error was 4.5 mm (interquartile range [IQR] 2.8–6.1 mm) for ON and 1.07 mm (IQR 0.71–1.59) for RA placement. Median entry point localization error was 5.5 mm (IQR 4.0–6.4) for ON and 0.71 mm (IQR 0.47–1.03) for RA placement. The difference in accuracy between Stealth-guided (ON) and RA placement was highly significant for both cortical entry point and target (p < 0.0001 for both). Increased soft-tissue thickness and intracranial length reduced accuracy at the target. Increased soft-tissue thickness, bone thickness, and younger age reduced accuracy at entry. There were no complications.CONCLUSIONSRA stereotactic electrode placement is highly accurate and is significantly more accurate than ON. Larger safety margins away from vascular structures should be used when placing deep electrodes in young children and for trajectories that pass through thicker soft tissues such as the temporal region.


2021 ◽  
pp. 200460
Author(s):  
Diana Toneva ◽  
Silviya Nikolova ◽  
Stanislav Harizanov ◽  
Dora Zlatareva ◽  
Vassil Hadjidekov

Author(s):  
Mohammed Mousa Bakri ◽  
Sung Ho Lee ◽  
Jong Ho Lee

Abstract Background A compact passive oxide layer can grow on tantalum (Ta). It has been reported that this oxide layer can facilitate bone ingrowth in vivo though the development of bone-like apatite, which promotes hard and soft tissue adhesion. Thus, Ta surface treatment on facial implant materials may improve the tissue response, which could result in less fibrotic encapsulation and make the implant more stable on the bone surface. The purposes of this study were to verify whether surface treatment of facial implant materials using Ta can improve the biohistobiological response and to determine the possibility of potential clinical applications. Methods Two different and commonly used implant materials, silicone and expanded polytetrafluoroethylene (ePTFE), were treated via Ta ion implantation using a Ta sputtering gun. Ta-treated samples were compared with untreated samples using in vitro and in vivo evaluations. Osteoblast (MG-63) and fibroblast (NIH3T3) cell viability with the Ta-treated implant material was assessed, and the tissue response was observed by placing the implants over the rat calvarium (n = 48) for two different lengths of time. Foreign body and inflammatory reactions were observed, and soft tissue thickness between the calvarium and the implant as well as the bone response was measured. Results The treatment of facial implant materials using Ta showed a tendency toward increased fibroblast and osteoblast viability, although this result was not statistically significant. During the in vivo study, both Ta-treated and untreated implants showed similar foreign body reactions. However, the Ta-treated implant materials (silicone and ePTFE) showed a tendency toward better histological features: lower soft tissue thickness between the implant and the underlying calvarium as well as an increase in new bone activity. Conclusion Ta surface treatment using ion implantation on silicone and ePTFE facial implant materials showed the possibility of reducing soft tissue intervention between the calvarium and the implant to make the implant more stable on the bone surface. Although no statistically significant improvement was observed, Ta treatment revealed a tendency toward an improved biohistological response of silicone and ePTFE facial implants. Conclusively, tantalum treatment is beneficial and has the potential for clinical applications.


Sign in / Sign up

Export Citation Format

Share Document