Influence of Crown-to-Implant Ratio on Long-Term Marginal Bone Loss Around Short Implants

2019 ◽  
Vol 34 (4) ◽  
pp. 992-998 ◽  
Author(s):  
Adolfo Di Fiore ◽  
Paolo Vigolo ◽  
Stefano Sivolella ◽  
Francesco Cavallin ◽  
Joannis Katsoulis ◽  
...  
2021 ◽  
Author(s):  
Wen Mo Gao ◽  
Wei Geng ◽  
Chen Chen Luo

Abstract Background: Restoration with locking-taper implants is a widely used methodology. However, relatively few have examined conical connection systems like locking-taper implant systems. This study provides a retrospective study of locking-taper fixed restorations, mainly focused on prosthetic complications.Methods: All patients who underwent conical connected implants from 2008–2010 were examined. Preparation of the implant sites was performed according to the standard procedures for the Bicon system. The bone healing took over 6 months, and the prosthetic procedure was initiated thereafter. Integrated abutment crowns or gold porcelain crowns were used, and the prosthesis type was a single crown or a fixed dental prosthesis. Once the crown was in place, its occlusion was thoroughly checked and adjusted, and then the crown was glazed or finely polished. The Kaplan-Meier method was used to calculate the cumulative complication-free rates for 5 and 10 years. Additionally, a Cox regression model was used to identify the factors that independently influenced the results. Implant survival and marginal bone loss were also investigated.Results: A total of 392 patients who underwent 541 implants and 434 locking taper implant-based restorations from 2008–2010 were examined. The overall 5-year cumulative complication-free rate was 83.34%. The most common prosthetic complication was veneer chipping, with a frequency of 67.53%. According to the Cox regression model, the complication-free rate of integrated abutment crowns was significantly higher than gold porcelain crowns, molar regions was significantly higher than premolar regions, and females was significantly higher than males. Only three implant failures happened, and a mean marginal bone loss at 1- year, 5-year and 10- year was 0.25mm(95%CI:±0.12), 0.40mm (95%CI:±0.03)and 0.51mm(95%CI:±0.05), respectively.Conclusion: Veneer chipping was the most common complication with locking-taper implants supported fixed restorations. According to the result of Cox regression model, gold porcelain crowns are a protective factor relative to integrated abutment crowns, male sex is a protective factor relative to female sex, and premolar prosthetics are a protective factor relative to molar prosthetics. The long-term clinical effect of locking-taper implant is stable, and the implant success rate can meet the clinical needs. The bone tissue level around the implant can maintain long-term stability.


Author(s):  
Giorgio Lombardo ◽  
Annarita Signoriello ◽  
Mauro Marincola ◽  
Pier Francesco Nocini

The aim of this retrospective study was to evaluate implant survival, marginal bone loss and peri-implant complications in 326 short and ultra-short implants. Implants were placed in the maxillary and mandibular posterior regions of 140 patients with (PP) and without (NPP) a history of periodontal disease. Clinical and radiographic examinations were performed at 3-year recall appointments. The 8.0, 6.0 and 5.0 mm-length implants placed in PP and NPP were respectively 43.75% and 38.46%, 35.10% and 34.19%, 21.15% and 27.35%; 325 implants (one early failure) were rehabilitated with single crowns in 139 patients. Overall implant survival after 3 years of follow-up was 97.55%, 98.08% and 96.61% for PP and NPP (p = 0.46). Crestal bone level variations were not statistically different among PP and NPP; 15.41% of implants presented signs of mucositis, 14.71% and 16.67% in PP and NPP (p = 0.64). Setting the threshold for bone loss at 2 mm after 36 months, peri-implantitis prevalence was 2.2%, 1.96% and 2.63% in PP and NPP (p = 0.7). Overall implant success was 82.39%, 83.33% and 80.7% for PP and NPP (p = 0.55). Short-term outcomes suggest that short and ultra-short locking-taper implants can successfully be restored with single crowns in the posterior jaws both in PP and NPP.


2019 ◽  
Vol 13 (01) ◽  
pp. 047-052 ◽  
Author(s):  
Eser Elemek ◽  
Artun Urgancioglu ◽  
Janberd Dincer ◽  
Altug Cilingir

Abstract Objective The use of dental implants with different types of surface roughness and implant-abutment interface has brought about a situation of marginal bone loss. Therefore, the aim of this study was to analyze and compare marginal bone levels of different types of osseointegrated dental implants with platform switch (Group A: Ankylos, Mannheim, Germany) and platform match (Group B: Dentsply Xive, Mannheim, Germany, and Group C: MIS Implant Technologies, Karmiel, Israel). Materials and Methods One hundred and seven patients (52 men and 55 women) with a mean age of 54.79 (standard deviation ± 12.35) years and a total of 321 dental implants (Group A, n = 198; Group B, n = 58; and Group C, n = 65) placed in a private practice between April 2006 and May 2015 were retrospectively analyzed. In addition to demographic information and implant characteristics, marginal bone levels were evaluated by Image J (Wayne Rasband, National Institute of Health, Maryland) program. Results The mean age of all patients was 54.79 ± 12.35 years, and 51.5% of them were women. Implants supporting fixed bridge were most commonly used in all groups (65%), whereas only 20% were restored with a single crown and 15% with overdentures. In total, 47.5% of all implants showed no marginal bone loss. Mean bone loss in Group A was significantly lower (0.81 ± 1.60 mm) as compared to Group B (1.58 ± 1.59 mm) and Group C (1.18 ± 1.36) (p < 0.005). Conclusion Among different types of dental implants, platform switch seems to preserve marginal bone levels and increase the long-term success of dental implants.


2018 ◽  
Vol 12 (1) ◽  
pp. 354-365 ◽  
Author(s):  
Priscila N. Uehara ◽  
Victor Haruo Matsubara ◽  
Fernando Igai ◽  
Newton Sesma ◽  
Marcio K. Mukai ◽  
...  

Aim: The aim of this systematic review was to compare the survival rate and the marginal bone loss between short implants (≤7 mm) placed in the atrophic area and longer implants placed in the augmented bone area of posterior regions of maxillaries. Methods: Electronic search using three databases was performed up to May 2017 to identify Randomized Controlled Trials (RCT) assessing short implants survival with a minimal follow-up of 12 months post-loading. For the meta-analysis, a Risk Difference (RD) with the 95% Confidence Interval (CI) was used to pool the results of implant failure rate for each treatment group. For the marginal bone changes, Mean Differences (MD) with 95% CI were calculated. Results: Seven randomized controlled trials met the inclusion criteria, being included in qualitative and quantitative analyses. The RD between the short implant group and the control group was -0.02 (95% CI: -0.04 to 0.00), I2=0 and Chi2=3.14, indicating a favorable survival rate for short implant, but with no statistical significance (p=0.09). Discussion: For marginal bone loss, the mean difference was -0,13 (95%CI: -0.22 to -0.05), favoring the test group with statistical significance (p=0.002). The studies showed more heterogeneity for bone loss compared to survival rate. Short and longer implants showed similar survival rates after one year of loading, however the marginal bone loss around short implants was lower than in longer implants sites. Conclusion: Placement of implants ≤7 mm of length was found to be a predictable alternative for the rehabilitation of atrophic posterior regions, avoiding all the disadvantages intrinsic to bone augmentation procedures.


2012 ◽  
Vol 2012 ◽  
pp. 1-8 ◽  
Author(s):  
Diego Lops ◽  
Eriberto Bressan ◽  
Gianluca Pisoni ◽  
Niccolò Cea ◽  
Boris Corazza ◽  
...  

Purpose.Evaluation of the short implant (8 mm in height) long-term prognosis and of the implant site influence on the prognosis.Methods.A longitudinal study was carried out on 121 patients (57 males and 64 females) consecutively treated with 257 implants. 108 implants were short.Results.Four (3.6%) short implants supporting fixed partial prostheses failed. Similarly, three standard implants supporting fixed partial prostheses and one supporting single-crown prosthesis failed. Mean marginal bone loss (MBL) and probing depth (PD) of short and standard implants were statistically comparable (P>.05). The 20-year cumulative survival rates of short and standard implants were 92.3 and 95.9%, respectively. The cumulative success rates were 78.3 and 81.4%. The survival rates of short implants in posterior and anterior regions were comparable: 95 and 96.4%, respectively. The difference between survival rates was not significant (P>.05).Conclusions.The high reliability of short implants in supporting fixed prostheses was confirmed. Short and standard implants long-term prognoses were not significantly different. The prognosis of short implants in posterior regions was comparable to that of in anterior regions. Nevertheless, a larger sample is required to confirm this trend.


Author(s):  
Cristina Ibañez ◽  
Andrés Catena ◽  
Pablo Galindo-Moreno ◽  
Blas Noguerol ◽  
Antonio Magán-Fernández ◽  
...  

2014 ◽  
Vol 29 (6) ◽  
pp. 1425-1428 ◽  
Author(s):  
Emanuel Bratu ◽  
Hsun-Liang Chan ◽  
Sorin Mihali ◽  
Olimpiu Karancsi ◽  
Dana Bratu ◽  
...  

2009 ◽  
Vol 11 (1) ◽  
pp. 11-23 ◽  
Author(s):  
Solweig Sundén Pikner ◽  
Kerstin Gröndahl ◽  
Torsten Jemt ◽  
Bertil Friberg

2019 ◽  
Vol 9 (7) ◽  
pp. 1282 ◽  
Author(s):  
Yeon-Wha Baek ◽  
Young-Jun Lim ◽  
Jungwon Lee ◽  
Ki-Tae Koo ◽  
Myung-Joo Kim ◽  
...  

The purpose of this randomized clinical trial is to evaluate immediately loaded single implants with varying lengths in the posterior mandible using a fully digital, model-free prosthetic-driven implant planning pathway, and to compare clinical and radiological outcomes of short and long implants. The 52 patients with the single tooth missing in the posterior molar regions of the mandible were randomly assigned to the control (CMI IS-III active® long implant; 5.0 × 10 mm) and experimental (CMI IS-III active® short implant; 5.5 × 6.6, 7.3, 8.5 mm) groups. For each patient, a single implant was placed using the computer aided surgical template and all prostheses were fabricated by means of computer-aided design/computer-aided manufacturing (CAD/CAM) system on the virtual model. The patients received provisional and definitive monolithic zirconia prostheses at 1 week and 12 weeks after implant surgery, respectively. The implant stability quotient (ISQ) measurements and periapical radiographs were taken and peri-implant parameters were evaluated at 1, 3, 4, 8, 12, 24, 36, and 48 weeks after surgery. Nineteen long implants and 27 short implants were finally used for the statistical analysis. There was no significant difference between the groups in terms of insertion torque, ISQ values (except 3 weeks), marginal bone loss, and peri-implant soft tissue parameters (p > 0.05). Both groups exhibited no stability dip during the early phase of healing. The average marginal bone loss from the baseline of implant placement for the control and experimental groups was −0.07 and 0.03 mm after 12 weeks and 0.06 and 0.05 mm after 48 weeks. All of the soft tissue parameters were within normal limits. Within the limits of the short term follow up, immediate loading of short single implants can be considered as one of predictable treatment modality in mandible with reduced bone height when primary stability can be achieved.


Sign in / Sign up

Export Citation Format

Share Document