Comparison of Clinical Performance of Zirconia Implants and Titanium Implants in Animal Models: A Systematic Review

2014 ◽  
Vol 29 (2) ◽  
pp. 311-320 ◽  
Author(s):  
Guillermo Manzano ◽  
L. Rubén Herrero ◽  
Javier Montero
2019 ◽  
Vol 34 (6) ◽  
pp. 1389-1396
Author(s):  
Nansi López-Valverde ◽  
Jorge Muriel-Fernández ◽  
Rafael Gómez de Diego ◽  
Juan Ramírez ◽  
Antonio López-Valverde

2017 ◽  
Vol 2017 ◽  
pp. 1-12 ◽  
Author(s):  
Ali Hafezeqoran ◽  
Roodabeh Koodaryan

Background. The information available about osseointegration and the bone to implant interaction of zirconia implants with various surface modifications is still far from sufficient.Objective. The purpose of this systematic review and meta-analysis was to evaluate and compare zirconia dental implants with different surface topographies, with a focus on bone to implant contact and removal torque.Methods. The systematic review of the extracted publications was performed to compare the bone to implant contact (BIC) with removal torque (RT) values of titanium dental implants and machined and surfaced modified zirconia implants.Results. A total of fifteen articles on BIC and RT values were included in the quantitative analysis. No significant difference in the BIC values was observed between titanium and machined zirconia implants (p=0.373; 95% CI:-0.166 to 0.443). However, a significantly better BIC values were observed for acid etched zirconia implants compared with those of titanium implants (p=0.032; 95% CI: 0.068 to 1.461). Unmodified zirconia implants showed favorable BIC values compared to modified-surface zirconia implants (p=0.021; 95% CI:-0.973 to-0.080).Conclusion. Acid etched zirconia implants may serve as a possible substitute for successful osseointegration.


2019 ◽  
Vol 14 (6) ◽  
pp. 504-518 ◽  
Author(s):  
Dilcele Silva Moreira Dziedzic ◽  
Bassam Felipe Mogharbel ◽  
Priscila Elias Ferreira ◽  
Ana Carolina Irioda ◽  
Katherine Athayde Teixeira de Carvalho

This systematic review evaluated the transplantation of cells derived from adipose tissue for applications in dentistry. SCOPUS, PUBMED and LILACS databases were searched for in vitro studies and pre-clinical animal model studies using the keywords “ADIPOSE”, “CELLS”, and “PERIODONTAL”, with the Boolean operator “AND”. A total of 160 titles and abstracts were identified, and 29 publications met the inclusion criteria, 14 in vitro and 15 in vivo studies. In vitro studies demonstrated that adipose- derived cells stimulate neovascularization, have osteogenic and odontogenic potential; besides adhesion, proliferation and differentiation on probable cell carriers. Preclinical studies described improvement of bone and periodontal healing with the association of adipose-derived cells and the carrier materials tested: Platelet Rich Plasma, Fibrin, Collagen and Synthetic polymer. There is evidence from the current in vitro and in vivo data indicating that adipose-derived cells may contribute to bone and periodontal regeneration. The small quantity of studies and the large variation on study designs, from animal models, cell sources and defect morphology, did not favor a meta-analysis. Additional studies need to be conducted to investigate the regeneration variability and the mechanisms of cell participation in the processes. An overview of animal models, cell sources, and scaffolds, as well as new perspectives are provided for future bone and periodontal regeneration study designs.


2021 ◽  
Vol 10 (1) ◽  
Author(s):  
Gabriela Elis Wachholz ◽  
Julia do Amaral Gomes ◽  
Juliano André Boquett ◽  
Fernanda Sales Luiz Vianna ◽  
Lavínia Schuler-Faccini ◽  
...  

Abstract Background Due to the diversity of studies in animal models reporting that molecular mechanisms are involved in the teratogenic effect of the Zika virus (ZIKV), the objective of the present study is to evaluate the methodological quality of these studies, as well as to demonstrate which genes and which molecular pathways are affected by ZIKV in different animal models. Methods This search will be performed in four databases: PubMed/MEDLINE, EMBASE, Web of Science, and Scopus, as well as in the grey literature. The studies selection process will be reported through the PRISMA Statement diagram model. All studies describing the molecular mechanisms possibly involved in the development of malformations caused by embryonic/fetal ZIKV exposure in animal models with an appropriate control group and methodology will be included (including, for instance, randomized and non-randomized studies). All animals used as experimental models for ZIKV teratogenesis may be included as long as exposure to the virus occurred during the embryonic/fetal period. From the selected studies, data will be extracted using a previously prepared standard form. Bias risk evaluation will be conducted following the SYRCLE’s Risk of Bias tool. All data obtained will be tabulated and organized by outcomes (morphological and molecular). Discussion With the proposed systematic review, we expect to present results about the methodological quality of the published studies with animal models that investigated the molecular mechanisms involved in the teratogenic effect of ZIKV, as well as to show the studies with greater reliability. Systematic review registration PROSPERO CRD42019157316


2021 ◽  
Vol 22 (7) ◽  
pp. 3800
Author(s):  
Ingmar A. J. van Hengel ◽  
Melissa W. A. M. Tierolf ◽  
Lidy E. Fratila-Apachitei ◽  
Iulian Apachitei ◽  
Amir A. Zadpoor

Patients receiving orthopedic implants are at risk of implant-associated infections (IAI). A growing number of antibiotic-resistant bacteria threaten to hamper the treatment of IAI. The focus has, therefore, shifted towards the development of implants with intrinsic antibacterial activity to prevent the occurrence of infection. The use of Ag, Cu, and Zn has gained momentum as these elements display strong antibacterial behavior and target a wide spectrum of bacteria. In order to incorporate these elements into the surface of titanium-based bone implants, plasma electrolytic oxidation (PEO) has been widely investigated as a single-step process that can biofunctionalize these (highly porous) implant surfaces. Here, we present a systematic review of the studies published between 2009 until 2020 on the biomaterial properties, antibacterial behavior, and biocompatibility of titanium implants biofunctionalized by PEO using Ag, Cu, and Zn. We observed that 100% of surfaces bearing Ag (Ag-surfaces), 93% of surfaces bearing Cu (Cu-surfaces), 73% of surfaces bearing Zn (Zn-surfaces), and 100% of surfaces combining Ag, Cu, and Zn resulted in a significant (i.e., >50%) reduction of bacterial load, while 13% of Ag-surfaces, 10% of Cu-surfaces, and none of Zn or combined Ag, Cu, and Zn surfaces reported cytotoxicity against osteoblasts, stem cells, and immune cells. A majority of the studies investigated the antibacterial activity against S. aureus. Important areas for future research include the biofunctionalization of additively manufactured porous implants and surfaces combining Ag, Cu, and Zn. Furthermore, the antibacterial activity of such implants should be determined in assays focused on prevention, rather than the treatment of IAIs. These implants should be tested using appropriate in vivo bone infection models capable of assessing whether titanium implants biofunctionalized by PEO with Ag, Cu, and Zn can contribute to protect patients against IAI.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Miren Vilor-Fernández ◽  
Ana-María García-De-La-Fuente ◽  
Xabier Marichalar-Mendia ◽  
Ruth Estefanía-Fresco ◽  
Luis-Antonio Aguirre-Zorzano

Abstract Background Oral implants have helped clinicians to improve the quality of life for many patients. The material of choice for dental implants currently remains titanium type IV, whose mechanical and biological properties have been proven throughout the history of implantology. Yet, this material is not exempt from complications. For these reasons, ceramic alternatives to titanium have emerged. Thus, the purpose of this study is to evaluate peri-implant hard and soft tissue stability with the use of a one-piece ceramic implant (Straumann® PURE Ceramic Implant) during 1 year of follow-up. Study design One-piece all-ceramic zirconia (ZrO2) implants were placed to replace single missing teeth in the esthetic zone. Six to 8 weeks after the procedure, the definitive prosthesis was fabricated. At the time of prosthesis, placement (T0) photographs and periapical radiographs were taken, and the following clinical parameters were recorded: probing depth (PD), plaque index (PI), bleeding on probing (BOP), suppuration on probing (SOP), distance from gingival margin to incisal edge (GM-IE), and Jemt papilla index (JPI). Follow-up appointments were scheduled at 4 (T4), 8 (T8), and 12 (T12) months, when the same parameters were recorded. In addition, plaque control was reinforced and prophylaxis was carried out. In this last appointment, a final periapical radiograph was taken to assess marginal bone loss. Results A total of 32 zirconia implants were placed in 28 patients (16 women and 12 men, aged between 34 and 67 years). The survival and success rate were 96.9%. The increase in probing depth from baseline to 12 months was 0.78 mm. Assessments of plaque index and bleeding on probing showed a slight increase throughout the study. Conclusions The results obtained with the Straumann® PURE Ceramic implants show them to exhibit very good clinical behavior. The survival rate of the implants of our pilot study was 96.9%. For these reasons, we can say that zirconia implants could be an alternative to titanium implants in the esthetic zone.


Sign in / Sign up

Export Citation Format

Share Document