Utility of Caudal Angulation for Venous Access under Fluoroscopic Guidance during Cardiovascular Implantable Electronic Device Implantation

Cardiology ◽  
2021 ◽  
pp. 1-5
Author(s):  
Siddharthan Deepti ◽  
Dhara Singh ◽  
Nirmal Ghati ◽  
Manish Shaw ◽  
Nitish Naik ◽  
...  

<b><i>Background:</i></b> Axillary venous access is preferred for CIED implantation. The procedure is usually performed under fluoroscopic guidance in anteroposterior (A-P) view. However, there is a lack of perception of depth in this view with a fear of creating complications. Caudal fluoroscopy (adding 30°–35° caudal angulation to A-P projection) has been proposed to circumvent this problem. <b><i>Objective:</i></b> The aim of this study was to elucidate the advantages of caudal fluoroscopy using fluoroscopic images, contrast venograms, and CT angiography images of axillary vein. <b><i>Methods:</i></b> The fluoroscopic images and contrast venograms obtained in the A-P view were compared with caudal fluoroscopy in patients undergoing CIED implantation at our centre. Also, the CT angiography images of axillary vein were reconstructed to understand the relative anatomy of the vein and the underlying lung parenchyma, simulating these 2 projections. <b><i>Results:</i></b> The CT angiography images, contrast venograms, and fluoroscopic images confirmed that caudal fluoroscopy allows better visualization of the vein in relation to the lung parenchyma and rib cage. Analysis of fluoroscopic images revealed that the bend of the first rib formed a conical prominence in caudal fluoroscopy. This served as an important bony landmark for successful venous access, which was usually obtained while the needle was being directed towards this prominence in caudal fluoroscopy. <b><i>Conclusions:</i></b> The proposed advantages of caudal fluoroscopy for CIED implantation have been elucidated by analysis of CT angiography images, contrast venograms, and fluoroscopic images.

2020 ◽  
Vol 6 (6) ◽  
pp. 661-671 ◽  
Author(s):  
Varunsiri Atti ◽  
Mohit K. Turagam ◽  
Jalaj Garg ◽  
Scott Koerber ◽  
Aakash Angirekula ◽  
...  

EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
T Lankveld ◽  
AMW Stipdonk ◽  
RJB Brans ◽  
JGLM Luermans ◽  
MW De Haan ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: None. Background Venous obstruction is relatively common after cardiac implantable electronic device (CIED) implantation. After CIED implantation 15% of the patients present with a severe or total occlusion. This poses a problem during lead revisions or upgrades often leading to implantation failure or complex extraction or lead tunneling procedures. Percutaneous balloon venoplasty might be a suitable option but is rarely performed. Purpose To identify the feasibility and safety of venoplasty during cardiac device implantation procedures. Methods We retrospectively included consecutive cardiac device implantations in which venoplasty was performed during the same procedure from December 2018 until December 2020. The venoplasty was done either planned or ad hoc, by an interventional radiologist. Results We included 17 patients, 14 (82%) were male, aged 73 ± 11 years. Fifteen (88%) patients required an upgrade or lead revision and two were de novo implantations. The subclavian vein was the site of occlusion in 13 (76%) patients. In 16 (94%) patients venoplasty was successful and all intended leads could be implanted subsequently. In the patient with the unsuccessful recanalization both an antegrade and retrograde approach via the vena femoralis was attempted. No venoplasty related complications occurred. The figure shows a succesful upgrade from a single chamber ICD (panel A) to a CRT-D (panel D) after venoplasty for a total occulsion of the vena subclavia (panel B and C).  Conclusions Percutaneous balloon venoplasty is a safe and feasible method for patients in whom venous access is an issue during CIED implantation. This method can be performed ad hoc and prevents contralateral lead implantation with tunneling or lead extraction. Abstract Figure. Venoplasty during upgrade.


Heart Rhythm ◽  
2021 ◽  
Vol 18 (8) ◽  
pp. S301-S302
Author(s):  
Danying Lee ◽  
Jo-Nan Liao ◽  
Tze-Fan Chao ◽  
Ta-Chuan Taun ◽  
Shih-Ann Chen

2020 ◽  
Vol 172 (2) ◽  
pp. 166
Author(s):  
Mehrdad Emami ◽  
Christopher X. Wong ◽  
Samuel Tu ◽  
Prashanthan Sanders ◽  
Glenn D. Young

EP Europace ◽  
2017 ◽  
Vol 19 (suppl_3) ◽  
pp. iii205-iii205
Author(s):  
J. Atenska-Pawlowska ◽  
M. Lewandowski ◽  
P. Syska ◽  
M. Sobiech ◽  
H. Szwed

2013 ◽  
Vol 24 (10) ◽  
pp. 1125-1129 ◽  
Author(s):  
JOHN M. JENNINGS ◽  
ROBERT ROBICHAUX ◽  
H. THOMAS MCELDERRY ◽  
VANCE J. PLUMB ◽  
ALICIA GUNTER ◽  
...  

2020 ◽  
Vol 75 (11) ◽  
pp. 439
Author(s):  
Jonathan Chandler ◽  
Nachiket Apte ◽  
John Fritzlen ◽  
Robert Weidling ◽  
Sean Lacy ◽  
...  

EP Europace ◽  
2017 ◽  
Vol 20 (8) ◽  
pp. 1318-1323 ◽  
Author(s):  
Jahangir Rashid Beig ◽  
Bilal A Ganai ◽  
Mohammad S Alai ◽  
Ajaz A Lone ◽  
Imran Hafeez ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document