One-Year Follow-Up in Children with Conductive Hearing Loss Using ADHEAR

2021 ◽  
pp. 1-10
Author(s):  
Mario E. Zernotti ◽  
Elvira Alvarado ◽  
Maximo Zernotti ◽  
Natalia Claveria ◽  
Maria F. Di Gregorio

<b><i>Background:</i></b> The ADHEAR™ system (MED-EL, Innsbruck, Austria) is a nonsurgical bone conduction device (BCD) to treat conductive hearing loss (CHL) and single-sided deafness. In contrast to the nonsurgical alternatives on headbands or spectacle frames, the audio processor of ADHEAR is placed retroauricularly on an adhesive adapter. The published evidence on the performance of this system is limited to studies with a trial period of 2–8 weeks. <b><i>Objective:</i></b> This study assesses audiological and subjective outcomes over a period of 12 months, on patients with congenital aural atresia (CAA) using the ADHEAR hearing system. <b><i>Method:</i></b> Fifteen children (mean age: 9.4 ± 4 years; range: 5–16 years) diagnosed with CAA (7 uni/8 bilateral) were included in this prospective, observational, repeated-measures study. Each subject used ADHEAR for 1 year, and the performance was evaluated after 1, 6, and 12 months. Free-field audiometry and speech discrimination tests were performed, and hearing-, general health- and device-specific questionnaires were used. <b><i>Results:</i></b> The unaided sound field threshold improved from an average PTA4 of 63.6 ± 3.4 dB HL to an aided average PTA4 of 29.3 ± 3.0 dB HL after 1 month of device use. The word recognition score (WRS) improved from an average of 27.9 ± 15.9% unaided to an aided average WRS of 91.3 ± 4.4% (<i>p</i> = 0.0003) after 1 month, 92.0 ± 4.1% (<i>p</i> = 0.0002) after 6 months, and 92.7 ± 5.3% (<i>p</i> &#x3c; 0.0001) after 12 months using the ADHEAR system compared to the unaided condition for all 3 time points. The improvements in the speech in noise at 1, 6, and 12 months were as well consistent over time. The average improvement at the signal to noise ratio (SNR) of +5 dB was 58% and 53% at the SNR of +0 dB. No complications were reported, and all patients continued to use the ADHEAR after the study end. The questionnaire results revealed high user satisfaction and an average wearing time of 12 h per day. <b><i>Conclusion:</i></b> This 12-month trial of the nonsurgical adhesive BCD in CAA patients showed sufficient and reliable audiological and subjective outcomes, long wearing time, and high acceptance. The ADHEAR can be considered a suitable option to treat children with CAA for the given indication, without the drawbacks of nonsurgical devices that use pressure for retention of the audio processor or the costs and possible complications involved with a surgical alternative.

1994 ◽  
Vol 3 (2) ◽  
pp. 52-58 ◽  
Author(s):  
Carol L. Mackersie ◽  
David R. Stapells

Wave I latencies were used to predict the magnitude of conductive components in 80 infants and young children (122 ears) with normal hearing, conductive hearing loss due to otitis media or aural atresia, sensorineural hearing loss, and mixed hearing loss. Two prediction methods were used. The first method based predictions on a 0.03-ms wave I latency delay for each decibel of conductive hearing loss. The second method was based on a regression analysis of wave I latency delays and the magnitude of conductive component for the subjects in this study with normal cochlear status. On average, these prediction methods resulted in prediction errors of 15 dB or greater in over one-third of the ears with hearing loss. Therefore, the clinical use of wave I latencies to predict the presence or magnitude of conductive impairment is not recommended for infants and young children. Instead, bone-conduction ABR testing is recommended as a direct measure of cochlear status when behavioral evaluation is not possible.


2021 ◽  
Vol 11 (4) ◽  
pp. 537-546
Author(s):  
Enrico Muzzi ◽  
Valeria Gambacorta ◽  
Ruggero Lapenna ◽  
Giulia Pizzamiglio ◽  
Sara Ghiselli ◽  
...  

A new non-invasive adhesive bone conduction hearing device (ABCD) has been proposed as an alternative solution for reversible bilateral conductive hearing loss in recurrent or long-lasting forms of otitis media with effusion (OME) in children that cannot undergo surgical treatment. Our aim was to assess the effectiveness of ABCD in children with OME. Twelve normal-hearing Italian-speaking volunteers, in whom a conductive hearing loss was simulated, participated in the study. The free-field average hearing threshold was determined and, to evaluate binaural hearing skills, loudness summation and the squelch effect were assessed. Five conditions were tested: (1) unaided without earplugs, (2) unaided with bilateral earplugs, (3) aided right ear with bilateral earplugs, (4) aided left ear with bilateral earplugs, and (5) bilateral aid with bilateral earplugs. Post-hoc analysis showed a significant statistical difference between plugged, unplugged, and each aided condition. The main results were a better loudness summation and a substantial improvement of the squelch effect in the bilaterally aided. Our results suggest that ABCD is a valid treatment for patients with conductive hearing loss that cannot undergo bone conduction implant surgery. It is also important to consider bilateral aids in order to deal with situations in which binaural hearing is fundamental.


2015 ◽  
Vol 36 (5) ◽  
pp. 826-833 ◽  
Author(s):  
Rik C. Nelissen ◽  
Emmanuel A. M. Mylanus ◽  
Cor W. R. J. Cremers ◽  
Myrthe K. S. Hol ◽  
Ad F. M. Snik

2020 ◽  
Vol 48 (12) ◽  
pp. 030006052097228
Author(s):  
Yujie Liu ◽  
Ran Ren ◽  
Shouqin Zhao

The Bonebridge and Vibrant Soundbridge systems are semi-implanted hearing devices, which have been widely applied in patients with congenital conductive hearing loss. However, comparison between these two hearing devices is rare, especially in the same patient. We report a 23-year-old man who underwent successive implantation of Vibrant Soundbridge and Bonebridge devices in the same ear because of dysfunction of the Vibrant Soundbridge. We provide insight on the patient’s experience and compare the audiological and subjective outcomes of satisfaction.


2016 ◽  
Vol 55 (11) ◽  
pp. 653-657 ◽  
Author(s):  
Marn Joon Park ◽  
Jae Ryung Lee ◽  
Chan Joo Yang ◽  
Myung Hoon Yoo ◽  
In Suk Jin ◽  
...  

1974 ◽  
Vol 83 (1) ◽  
pp. 125-127 ◽  
Author(s):  
Vincent W. Byers

The conductive SISI (short increment sensitivity index) test is an indirect procedure to estimate bone-conduction thresholds for middle ear pathology patients. A series of SISI tests are run, beginning at 20 dB S.L. and increasing in 10 dB S.L. steps, until a 100% SISI score is obtained. The following equation predicts the bone-conduction threshold: [Formula: see text] The results of 25 conductive SISI tests on a conductive hearing loss group indicate that the equation approximates the measured B.C. threshold. There was no statistical difference between the predicated B.C. thresholds (12.4 dB) and measured B.C. thresholds (10.4 dB) for the group.


2020 ◽  
Vol 41 (3) ◽  
pp. 379-385
Author(s):  
Ohad Hilly ◽  
Meirav Sokolov ◽  
Reut Beck Finkel ◽  
Ofir Zavdy ◽  
Rafael Shemesh ◽  
...  

2020 ◽  
Vol 25 (2) ◽  
pp. 85-93
Author(s):  
Ahmed Tariq ◽  
Mostafizur Rahman ◽  
Delwar Hossain ◽  
Sheikh Hasanur Rahman

Otosclerosis is the most frequent cause of conductive hearing loss in patients with intact tympanic membrane. It can be treated by surgery with various techniques. Because of limited manipulation and comparably similar results, stapedotomy at present is preferred over other surgical techniques by most surgeons. Here we present the operative results of 35 otosclerotic patients who underwent stapedotomy between January 2009 - October 2010 in the department of Otolaryngology- Head & Neck Surgery of Bangabandhu Sheikh Mujib Medical University, Dhaka Medical College Hospital and Shahid Suhrawardhy medical college & hospital, Dhaka. The aim of this study was to evaluate the hearing results following stapedotomy in otosclerosis surgery. The average air-bone gap of patients improved significantly to 21.74 dB after operation. Other hearing parameters of patients (including air conduction, bone conduction, speech discrimination score, and tinnitus) also improved. No patient experienced persistent vertigo after the operation and pre operative tinnitus resolved in 12 out of 22 patients. Stapedotomy is a safe and effective modality for improving conductive hearing loss in otosclerotic patients. Bangladesh J Otorhinolaryngol; October 2019; 25(2): 85-93


Sign in / Sign up

Export Citation Format

Share Document