Integrated Intraoperative Optical Coherence Tomography in Pediatric Glaucoma Surgery

Author(s):  
Amgad Eldib ◽  
Sarah Janczewski ◽  
Ken K. Nischal
2020 ◽  
Vol 2020 ◽  
pp. 1-5
Author(s):  
Akiko Ishida ◽  
Kazunobu Sugihara ◽  
Tomoki Shirakami ◽  
Aika Tsutsui ◽  
Kaoru Manabe ◽  
...  

Purpose. Observation of ocular structures using microscope-integrated intraoperative optical coherence tomography (iOCT) has been adopted. Using the novel digital ophthalmic microscope, ARTEVO 800 with iOCT, we tested the feasibility of trabecular meshwork (TM) imaging during microhook ab interno trabeculotomy, a minimally invasive glaucoma surgery. Methods. The nasal and temporal sides of the TM/inner wall of Schlemm’s canal were incised more than 3 clock hours in 14 glaucomatous eyes of 10 patients. To observe the trabeculotomy site, iOCT was performed with the real-time five-line scan mode under observation using a Swan-Jacob gonioprism lens. The success of the imaging and visibility of the trabeculotomy cleft and its incisional patterns (i.e., anterior, middle, or posterior pattern) were determined by reviewing the iOCT video files. Results. OCT images of the region of interest were acquired successfully in 100% of the 28 nasal or temporal sides in 14 eyes, although the trabeculotomy cleft was not visualized in four (14%) sides due to blockage of the OCT signal by a blood clot. Based on the predominant locations of the TM flaps in 24 of the acquired images, the trabeculotomy clefts were classified as anterior incisional patterns in 13 (54%), middle incisional patterns in nine (38%), and posterior incisional patterns in two (8%). Conclusion. Intraoperative imaging of the gonio structures including the trabeculotomy cleft was feasible using the ARTEVO 800 with iOCT in combination with a gonioprism.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Michael Mimouni ◽  
Martin Kronschläger ◽  
Manuel Ruiss ◽  
Oliver Findl

Abstract Background Remnant interface fluid following Descemet stripping automated endothelial keratoplasty (DSAEK) is associated with postoperative detachments. The aim of this study was to assess outcomes of intraoperative optical coherence tomography (iOCT) guided meticulous peripheral corneal sweeping for removal of interface fluid during ultra-thin (UT) DSAEK. Methods This retrospective study included all eyes underwent iOCT guided UT-DSAEK from October 2016 to February 2018 at the Hanusch Hospital, Vienna, Austria. Peripheral meticulous corneal sweeping was performed to remove excess fluid. Central graft thickness (CGT) was measured prior to surgery, after graft bubbling and after corneal sweeping. Remnant interface fluid rates were compared between eyes that underwent rebubbling and those that did not. Results Overall, 28 eyes of 28 patients with a mean age of 73.9 ± 10.0 years were included. An iOCT guided meticulous peripheral sweeping was performed in 89.3% (n = 25) of the cases. Following 84% (n = 21) of the peripheral sweeping performed, remnant fluid was no longer identified. Following peripheral sweeping the interface fluid height was reduced from 17.31 ± 15.96 μm to 3.46 ± 9.52 μm (p < 0.001) and CGT was reduced by 7% (p < 0.001). Rebubbling was performed in 17.9% (n = 5) of the cases. The rebubbling group had a greater proportion of patients that had remnant fluid identified with iOCT at the end of surgery despite meticulous peripheral sweeping (60.0% versus 4.4%, p = 0.01). Conclusion The iOCT identified subclinical remnant fluid in nearly 90% of UT-DSAEK cases. An iOCT guided peripheral corneal sweeping led to resolution of interface fluid in a majority of cases. Eyes with persistent remnant fluid despite peripheral corneal sweeping are more likely to require subsequent rebubbling.


2021 ◽  
Author(s):  
Bachar Kudsieh ◽  
José Ignacio Fernández‐Vigo ◽  
Maria Isabel Canut Jordana ◽  
Jorge Vila‐Arteaga ◽  
Javier Aritz Urcola ◽  
...  

2016 ◽  
Vol 2 (4) ◽  
Author(s):  
Sara Lombardo ◽  
Alice Chandra Verticchio Vercellin ◽  
Marta Raimondi ◽  
Carmine Tinelli ◽  
Giovanni Milano

Sign in / Sign up

Export Citation Format

Share Document