Evaluation of Biomechanically Corrected Intraocular Pressure Measurements in Keratoconus and Forme Fruste Keratoconus

2020 ◽  
Vol 63 (6) ◽  
pp. 541-549
Author(s):  
Tomoya Nishida ◽  
Takashi Kojima ◽  
Takahiro Kataoka ◽  
Naoki Isogai ◽  
Yoko Yoshida ◽  
...  

<b><i>Introduction:</i></b> Although biomechanically corrected intraocular pressure (bIOP) is available, the effectiveness of intraocular pressure (IOP) correction in keratoconus and forme fruste keratoconus (FFK) eyes has not been investigated. <b><i>Objective:</i></b> Evaluation of bIOP measurements in eyes with keratoconus and FFK. <b><i>Methods:</i></b> Forty-two eyes in 21 patients with keratoconus in one eye and FFK in the fellow eye were examined (KC/FFK group; mean age 24.62 ± 8.6 years; 16 males and 5 females). The control group consisted of 62 eyes in 31 unaffected subjects (mean age 26.26 ± 3.64 years; 15 males and 16 females). The bIOP was determined using a Scheimpflug-based tonometer (Corvis Scheimpflug Technology [Corvis ST®]) after measuring the IOP with a conventional non-contact tonometer (NIOP). The agreement between NIOP and bIOP values was examined using the Bland-Altman plot. The difference between NIOP and bIOP (bIOP correction amount) was compared between keratoconus and FFK eyes. <b><i>Results:</i></b> In the control group, there were no significant differences between right and left eyes in both NIOP and bIOP values (<i>p</i> = 0.975 and <i>p</i> = 0.224, respectively). In the KC/FFK group, NIOP values were significantly lower in the keratoconus eyes (9.93 ± 1.96 mm Hg) than in the FFK eyes (12.23 ± 3.03 mm Hg; <i>p</i> = 0.0003). There was no significant difference in bIOP values between the right and left eyes of the KC/FFK group (<i>p</i> = 0.168). The bIOP correction amount was significantly increased in keratoconus eyes (3.58 ± 2.12 mm Hg) compared to in FFK eyes (1.80 ± 3.32 mm Hg; <i>p</i> = 0.011). <b><i>Conclusions:</i></b> For eyes with keratoconus and FFK, the bIOP method is effective to adjust IOP measurements based on corneal biomechanical properties.

2020 ◽  
Vol 237 (04) ◽  
pp. 392-395
Author(s):  
Olga Zabek ◽  
Georgios D. Panos ◽  
Despoina Sagri ◽  
Konstantin Gugleta ◽  
Hendrik P. N. Scholl ◽  
...  

Abstract Objective In this report, we investigated the association between the intraocular pressure (IOP) values by two different measurement methods and the corneal biomechanical properties in a patient with keratoconus and secondary glaucoma due to pseudoexfoliation syndrome who developed a marked elevation of intraocular pressure in the right eye. Methods IOP was measured over a period of 3 days with Goldmann applanation tonometry (GAT) and dynamic contour tonometry (Pascal tonometry, DCT). Corneal hysteresis (CH) and corneal resistance factor (CRF) were estimated with the aid of an ocular response analyzer (ORA). Results CH and CRF were significantly reduced in the right eye compared to the left eye throughout the period of observation (paired t-test, p < 0.001). The difference between both methods of IOP measurement in the right eye was statistically significant for IOP < 30 mmHg by GAT (Wilcoxon test, p = 0.004). For IOP values > 30 mmHg by GAT, there was no statistically significant difference between DCT and GAT (Wilcoxon test, p = 0.0625). Conclusions This observation supports the clinical hypothesis that a significant decrease in CH translates to a decreased correlation of CH and IOP recordings by GAT and, furthermore, suggests that after a critical point of CH reduction, the impact of CH on GAT may be comparable to that on DCT.


2021 ◽  
Vol 13 (2) ◽  
pp. 137-144
Author(s):  
Sanket Parajuli ◽  
Pooja Shrestha ◽  
Jeevan K Shrestha ◽  
Sadhana Sharma

Introduction: Systemic blood pressure, by far, is one of the most important factors that can have an effect on intraocular pressure. We have compared the intraocular pressure (IOP) among patients with systemic hypertension and those with normal blood pressure. Materials and methods: A hospital based case control study was conducted from March 2017 to March 2018 in the Ophthalmology outpatient department at Dhulikhel Hospital. A total of 100 patients with hypertension were included in the case group (hypertensive group) and 100 cases with no systemic or ocular disease were included in the control group (normotensive group). Mean intraocular pressures were calculated and compared between the two groups. Results: Mean age of patients was 49.03 years in hypertensive group and 47.53 years in normotensive group. Mean IOP of the right eye in those with hypertension was 16.10 mmHg and in the left eye was 15.8 mmHg. Similarly mean IOP of the right eye in the normotensive group was 15.8 mmHg and the left eye was 16.2 mmHg. The difference between mean IOP of hypertensive and normotensive individuals was not statistically significant (p > 0.05). The prevalence of ocular hypertension was found to be 7.5%. Conclusion: There was no statistically significant difference in IOP between hypertensive and normotensive individuals. However, a statistically significant difference in IOP was noted between ‘hypertensive with controlled blood pressure’ and ‘hypertensive with uncontrolled BP’ indicating that high blood pressure may be associated with high IOP.


2021 ◽  
Vol 2021 ◽  
pp. 1-7
Author(s):  
Chao Xue ◽  
Yaoqi Xiang ◽  
Yi Song ◽  
Min Shen ◽  
Di Wu ◽  
...  

Purpose. To investigate the difference between the eyes from the same human with respect to the biomechanical properties of fresh corneal tissues and investigate the assumption of similarity of the corneal biomechanical properties between the eyes. Methods. Strip specimens extracted through a small incision lenticule extraction (SMILE) surgery were tested using a uniaxial tensile test. The specimens were extracted vertically. Low-strain tangent modulus (LSTM), high-strain tangent modulus (HSTM), and tensile strength ( σ b ) were the biomechanical parameters used in the comparison of the eyes from the same human. Results. Ninety corneal specimens from 45 persons were included in this study. The LSTM of the left and right eyes were 1.34 ± 0.52 and 1.37 ± 0.46 MPa, while the HSTM were 50.53 ± 7.51 and 49.41 ± 7.01 MPa, respectively. There was no significant difference between the eyes in terms of LSTM, HSTM, and σ b P = 0.813 ,   0.335 ,   and  0.605 ,   resp . . The LSTM and HSTM were significantly correlated with the spherical equivalent (SE) ( P ≤ 0.01 ,   P = 0.001 , resp.). Conclusions. The assumption that the corneal biomechanical properties of the eyes from the same human are similar has been confirmed for the first time using fresh human corneal tissue. This finding may be useful in further biomechanical studies.


2020 ◽  
Vol 2020 ◽  
pp. 1-6
Author(s):  
Zongli Hu ◽  
Chunlin Chen ◽  
Min Sun ◽  
Rongdi Yuan ◽  
Jian Ye

Purpose. To confirm the relationship between anterior chamber angle (ACA) and intraocular pressure (IOP) early after V4c implantable collamer lens (ICL) implantation. Methods. Patients were assigned to two groups: (1) right eyes (control group) and (2) left eyes (experimental group), with miosis conducted immediately after ICL implantation in the left eyes. IOP, angle opening distance (AOD), trabecular-iris angle (TIA), and pupil diameter (PD) were compared between two groups at postoperative hours 1, 2, and 24. The relationship between ACA, PD, and IOP was analyzed by multiple linear regression. Result. Thirty-six eyes of 18 patients were enrolled. The prevalence of ocular hypertension (OHT, defined as IOP ≥ 21 mmHg) was 61.11% and 16.67% in the right and left eyes, respectively, (χ2 = 7.481, p=0.006). At postoperative hours 1 and 2, IOP and PD were significantly higher p<0.001 in the right eyes, and TIA and AOD were significantly lower p<0.05 in the right eyes than in the left eyes. There was no significant difference at 24 h postoperative in these parameters. After the right eye ICL implantation, the changes of AOD 500 and PD were both linearly correlated with postoperative IOP change (β = −23.707 and 1.731, respectively; p = 0.013 and 0.002, respectively). Conclusion. The ACA was significantly narrowed immediately after V4c ICL implantation. There was a negative linear correlation between ACA and early IOP and a positive linear correlation between PD and early IOP. We recommend the use of intracameral miotics immediately after V4c ICL implantation to reduce the incidence of IOP spikes.


2020 ◽  
Vol 22 (Supplement_2) ◽  
pp. ii178-ii178
Author(s):  
Xing Zhang ◽  
Fuqiang Zhang ◽  
Mingyao Lai ◽  
Juan Li ◽  
Yangqiong Zhang ◽  
...  

Abstract OBJECTIVE To explore the effect of group medical games on the hospitalization adaptability of pediatric patients with neuro tumor. METHODS pediatric patients with neuro tumor (age:6 to 13 years) who were treated in hospital from June to December 2019 and were hospitalized for 1 month to 2 months. 29 pediatric patients(mean age:9y) were selected as the control group and treated as usual; 26 pediatric patients(meanage:8y) were selected as the experimental group for group therapeutic play intervention. Interventions last Monday, Wednesday and Friday of each week, with an average duration of one hour. Group medical play include: medical picture book education, medical preview game, emotional games, social table games. Two groups completed self-made questionnaires at the time of admission and two weeks after admission, including: diet, sleep, compliance, and social status, hospital adaptation and other related issues, two groups completed a satisfaction questionnaire after two weeks of admission, recorded analysis and compared the difference of questionnaire data and satisfaction of the two groups of pediatric patients. RESULTS There was no statistical difference in age and sex between the two groups, and there was no significant difference in baseline RESULTS: The re-test results showed that the experimental group was significantly better than the control group in terms of social status, hospital adaptation, compliance and family satisfaction(p<0.05). CONCLUSION Group medical games can effectively improve the adaptability, compliance and family satisfaction of pediatric with neuro tumor.


2021 ◽  
pp. 1-8
Author(s):  
Sevde Aksu ◽  
Pelin Palas Karaca

<b><i>Aim:</i></b> The research was conducted as a randomized controlled pilot study to evaluate the effects of reflexology on lactation in mothers who delivered by cesarean section (CS). <b><i>Methods:</i></b> A single-blind randomized controlled experimental study was conducted with a total of 60 postpartum women in the reflexology application (<i>n</i> = 30) and control groups (<i>n</i> = 30). After the CS, the mothers in the control group were given approximately 3-h routine nursing care after recovering from the effects of anesthesia; the introductory information form was applied, and the Breastfeeding Charting System and Documentation Tool (LATCH) and visual analog scale (VAS) for the signs of the onset of lactation were implemented on the first and second days. Reflexology was applied to the women in the intervention group after an average of 3 h following the mother’s condition had become stable and she had recovered from the effects of anesthesia. Reflexology was applied a total of 20 min – 10 min for the right foot, 10 min for the left foot – twice a day with 8-h intervals on the first and second days after CS. After the last reflexology application, the LATCH and VAS for the signs of the onset of lactation were applied. <b><i>Results:</i></b> Of the women, 70% breastfed their babies within 60 min after delivery; 46.7% of the mothers received breastfeeding training and 81.7% needed support for breastfeeding after the CS. The LATCH breastfeeding scores of the women in the intervention group on both days were significantly higher compared to those of the women in the control group (<i>p</i> &#x3c; 0.001). On the first day after the CS, apart from breast pain, there was no significant difference between the two groups in terms of breast heat and breast tension (<i>p</i> &#x3e; 0.05). On the second day after the CS, apart from breast tension, there was no significant difference between the groups in terms of breast heat and breast pain (<i>p</i> &#x3c; 0.05). In the study, women in the intervention group were found to have higher scores in terms of all three symptoms compared to the control group (<i>p</i> &#x3c; 0.05). <b><i>Conclusions:</i></b> In the study, it was determined that LATCH scores and signs of the onset of breastfeeding increased in the mothers who received reflexology after CS.


Author(s):  
Graziela Maria Martins-Moreira ◽  
Alessandra Spada Durante

Abstract Introduction Good hearing in pilots, including central auditory skills, is critical for flight safety and the prevention of aircraft accidents. Pure tone audiometry alone may not be enough to assess hearing in the members of this population who, in addition to high noise levels, routinely face speech recognition tasks in non-ideal conditions. Objective To characterize the frequency-following response (FFR) of a group of military pilots compared with a control group. Methods Twenty military pilots in the Study Group and 20 non-pilot military personnel, not exposed to noise in their work, in the Control Group, all with normal hearing, aged between 30 and 40 years old, completed a questionnaire to assess their hearing habits, and their FFRs were measured with a /da/ syllable (duration 40 milliseconds, speed 10.9/s), at 80 dB NA in the right ear. All procedures were approved by the ethical committee of the institution. Statistical analysis was performed using the t-Student or Mann-Whitney tests for quantitative variables, and the Fisher or chi-squared tests for qualitative variables, and a value of p < 0.05 was considered to be statistically significant. Results There was no significant difference between the groups regarding auditory habits. In the FFR, wave amplitudes A (p = 0.01) and C (p = 0.04) were significantly lower in the Study Group. Conclusion Working as a military pilot can be a crucial factor in determining an individual's typical FFR pattern, demonstrated in the present study by statistically significant reductions in the amplitudes of the A and C waves.