Comparative Study of Robot-Assisted versus Conventional Frame-Based Deep Brain Stimulation Stereotactic Neurosurgery

2018 ◽  
Vol 96 (5) ◽  
pp. 327-334 ◽  
Author(s):  
Clemens Neudorfer ◽  
Stefan Hunsche ◽  
Martin Hellmich ◽  
Faycal El Majdoub ◽  
Mohammad Maarouf
2019 ◽  
Vol 19 (1) ◽  
pp. 57-64 ◽  
Author(s):  
Lannie Liu ◽  
Sarah Giulia Mariani ◽  
Emmanuel De Schlichting ◽  
Sylvie Grand ◽  
Michel Lefranc ◽  
...  

Abstract BACKGROUND Frameless robotic-assisted surgery is an innovative technique for deep brain stimulation (DBS) that has not been assessed in a large cohort of patients. OBJECTIVE To evaluate accuracy of DBS lead placement using the ROSA® robot (Zimmer Biomet) and a frameless registration. METHODS All patients undergoing DBS surgery in our institution between 2012 and 2016 were prospectively included in an open label single-center study. Accuracy was evaluated by measuring the radial error (RE) of the first stylet implanted on each side and the RE of the final lead position at the target level. RE was measured on intraoperative telemetric X-rays (group 1), on intraoperative O-Arm® (Medtronic) computed tomography (CT) scans (group 2), and on postoperative CT scans or magnetic resonance imaging (MRI) in both groups. RESULTS Of 144 consecutive patients, 119 were eligible for final analysis (123 DBS; 186 stylets; 192 leads). In group 1 (76 patients), the mean RE of the stylet was 0.57 ± 0.02 mm, 0.72 ± 0.03 mm for DBS lead measured intraoperatively, and 0.88 ± 0.04 mm for DBS lead measured postoperatively on CT scans. In group 2 (43 patients), the mean RE of the stylet was 0.68 ± 0.05 mm, 0.75 ± 0.04 mm for DBS lead measured intraoperatively; 0.86 ± 0.05 mm and 1.10 ± 0.08 mm for lead measured postoperatively on CT scans and on MRI, respectively No statistical difference regarding the RE of the final lead position was found between the different intraoperative imaging modalities and postoperative CT scans in both groups. CONCLUSION Frameless ROSA® robot-assisted technique for DBS reached submillimeter accuracy. Intraoperative CT scans appeared to be reliable and sufficient to evaluate the final lead position.


2020 ◽  
Vol 6 (1) ◽  
Author(s):  
Hai Jin ◽  
Shun Gong ◽  
Yingqun Tao ◽  
Hua Huo ◽  
Xiao Sun ◽  
...  

Abstract To compare the differences between asleep and awake robot-assisted deep brain stimulation (DBS) surgery for Parkinson’s Disease (PD), we conducted this retrospective cohort study included 153 PD patients undergoing bilateral robot-assisted DBS from June 2017 to August 2019, of which 58 cases were performed under general anesthesia (GA) and 95 cases under local anesthesia (LA). Procedure duration, stimulation parameters, electrode implantation accuracy, intracranial air, intraoperative electrophysiological signal length, complications, and Unified PD Rating Scale (UPDRS) measurements were recorded and compared. The clinical evaluation was conducted by two raters who were blinded to the choice of anesthesia. Procedure duration was significantly shorter in the GA group, while on stimulation off medication motor scores (UPDRS-III) were significantly improved in both the GA and LA group. ANCOVA covariated for the baseline UPDRS-III and levodopa challenge exhibited no significant differences. In terms of amplitude, frequency, and pulse width, the stimulation parameters used for DBS power-on were similar. There were no significant differences in electrode implantation accuracy, intraoperative electrophysiological signal length, or intracerebral hemorrhage (no occurrences in either group). The pneumocephalus volume was significantly smaller in the GA group. Six patients exhibited transient throat discomfort associated with tracheal intubation in the GA group. The occurrence of surgical incision infection was similar in both groups. Compared with the awake group, the asleep group exhibited a shorter procedure duration with a similar electrode implantation accuracy and short-term motor improvement. Robot-assisted asleep DBS surgery is a promising surgical method for PD.


Neurosurgery ◽  
2020 ◽  
Vol 88 (1) ◽  
pp. 165-173
Author(s):  
Catherine H Moran ◽  
Mariusz Pietrzyk ◽  
Nagaraja Sarangmat ◽  
Carter S Gerard ◽  
Neil Barua ◽  
...  

ABSTRACT BACKGROUND Recent advances in methods used for deep brain stimulation (DBS) include subthalamic nucleus electrode implantation in the “asleep” patient without the traditional use of microelectrode recordings or intraoperative test stimulation. OBJECTIVE To examine the clinical outcome of patients who have undergone “asleep” DBS for the treatment of Parkinson disease using robot-assisted electrode delivery. METHODS This is a retrospective review of clinical outcomes of 152 consecutive patients. Their outcomes at 1 yr postimplantation are reported; these include Unified Parkinson's Disease Rating Scale (UPDRS) assessment, Tinetti Mobility Test, Parkinson's Disease Questionnaire (PDQ)-39 quality of life assessment, Mattis Dementia Rating Scale, Beck Depression Inventory, and Beck Anxiety. We also report on a new parietal trajectory for electrode implantation. RESULTS A total of 152 patients underwent assessment at 1 yr. UPDRS III improved from 39 to 20.5 (47%, P < .001). The total UPDRS score improved from 67.6 to 36.4 (46%, P < .001). UPDRS II scores improved from 18.9 to 10.5 (44%, P < .001) and UPDRS IV scores improved from 7.1 to 3.6 (49%, P < .001). There was a significant reduction in levodopa equivalent daily dose after surgery (mean: 35%, P < .001). PDQ-39 summary index improved by a mean of 7.1 points. There was no significant difference found in clinical outcomes between the frontal and parietal approaches. CONCLUSION “Asleep” robot-assisted DBS of the subthalamic nucleus demonstrates comparable outcomes with traditional techniques in the treatment of Parkinson disease.