Changes in Immunochemical Characteristics of Blood Proteins in Experimental Conditions

Author(s):  
G. M. Malakhova ◽  
V. V. Suzdaleva ◽  
G. I. Kazakova ◽  
V. D. Pupinina
1917 ◽  
Vol 25 (2) ◽  
pp. 231-253 ◽  
Author(s):  
S. H. Hurwitz ◽  
G. H. Whipple

The intoxication which develops as the result of a simple obstruction or a closed intestinal loop is accompanied by definite changes in the coagulable proteins of the blood serum. These changes consist essentially in an alteration in the normal albumin-globulin ratio; the globulin fraction is greatly increased and at times the normal relation of the two fractions may show a complete inversion. The increase in the globulin content of the blood serum is most marked in the animals which show some of the complications met with in loop animals,—rupture of the loop and peritonitis. In the latter conditions especially, the globulin increase is rapid and large. We believe this reaction to be of diagnostic value in acute infections attended by the sudden liberation and absorption of a toxic exudate. Infections and intoxications produced by inflammatory irritants are also accompanied by a rise in the blood globulins. This observation suggests that tissue disintegration with absorption of toxic products is responsible for the changes noted, and that bacterial invasion is important only in as far as it gives rise to toxic substances. Animals which have developed a tolerance to proteose intoxication following the periodic injection of small doses of proteose do not show a globulin increase. These experiments do not support the view that the rise in globulins observed in these experimental conditions is an expression of a resistance or tolerance developed by the animal. From the experimental evidence it seems more probable that the alteration in the partition of the blood protein fractions is one of the results of the metabolic disturbance which has been shown to occur in these conditions.


2020 ◽  
Vol 142 (8) ◽  
Author(s):  
Renata T. Silva ◽  
Aloysio A. S. Campos ◽  
Edson J. Soares ◽  
Leonardo dos Santos ◽  
Renato N. Siqueira

Abstract Drag reduction (DR) by polymers has several industrial applications, and it has also shown to produce beneficial effects on blood circulation and may represent a way to treat cardiovascular disorders. Concerning medical applications, there are basically two types of studies using drag reducing polymers (DRP), i.e., in vitro and in vivo. Although blood may be used in the in vitro studies, there are several limitations, such as incompatibility of Rh and possibility of denaturing blood proteins. Thus, biomedical researchers commonly use an artificial plasma-like saline nutrient solution (SNS), which contains ions, nutrients, a buffer to maintain pH levels and a supply of oxygen to the tissue. The behavior of the DRP in water is well reported in the literature, but the SNS components can interact with the polymers, changing their capacity to reduce drag. This study investigates the behavior of three different polymers, i.e., polyacrylamide (PAM), polyethylene oxide (PEO), and xanthan gum (XG), when applied as DRP to a commonly used SNS. For the conditions evaluated, the SNS composition does not change significantly PAM and PEO behavior, showing that they can be satisfactorily diluted in this solvent without loss of efficiency as drag reducers. However, it modifies XG conformation, drastically reducing its efficiency. The experiments with tail arterial beds suggest that PAM is efficient to reduce the perfusion pressure, but PEO and XG do not seem to be good reducers under the experimental conditions that have been analyzed, possibly due to the interaction of the drag reducers with the flow, with the solvent components and with the tissues that were kept alive during the experiments. Although PEO did not present a good performance as DRP for the conditions evaluated in the perfusion tests, its performance can be improved in other organs where the turbulence levels, or instabilities, are higher, as suggested by the rheometer tests.


Author(s):  
F. I. Grace ◽  
L. E. Murr

During the course of electron transmission investigations of the deformation structures associated with shock-loaded thin foil specimens of 70/30 brass, it was observed that in a number of instances preferential etching occurred along grain boundaries; and that the degree of etching appeared to depend upon the various experimental conditions prevailing during electropolishing. These included the electrolyte composition, the average current density, and the temperature in the vicinity of the specimen. In the specific case of 70/30 brass shock-loaded at pressures in the range 200-400 kilobars, the predominant mode of deformation was observed to be twin-type faults which in several cases exhibited preferential etching similar to that observed along grain boundaries. A novel feature of this particular phenomenon was that in certain cases, especially for twins located in the vicinity of the specimen edge, the etching or preferential electropolishing literally isolated these structures from the matrix.


Author(s):  
Nalin J. Unakar

The increased number of lysosomes as well as the close approximation of lysosomes to the Golgi apparatus in tissue under variety of experimental conditions is commonly observed. These observations suggest Golgi involvement in lysosomal production. The role of the Golgi apparatus in the production of lysosomes in mouse liver was studied by electron microscopy of liver following toxic injury by CCI4.


Author(s):  
M. Locke ◽  
J. T. McMahon

The fat body of insects has always been compared functionally to the liver of vertebrates. Both synthesize and store glycogen and lipid and are concerned with the formation of blood proteins. The comparison becomes even more apt with the discovery of microbodies and the localization of urate oxidase and catalase in insect fat body.The microbodies are oval to spherical bodies about 1μ across with a depression and dense core on one side. The core is made of coiled tubules together with dense material close to the depressed membrane. The tubules may appear loose or densely packed but always intertwined like liquid crystals, never straight as in solid crystals (Fig. 1). When fat body is reacted with diaminobenzidine free base and H2O2 at pH 9.0 to determine the distribution of catalase, electron microscopy shows the enzyme in the matrix of the microbodies (Fig. 2). The reaction is abolished by 3-amino-1, 2, 4-triazole, a competitive inhibitor of catalase. The fat body is the only tissue which consistantly reacts positively for urate oxidase. The reaction product is sharply localized in granules of about the same size and distribution as the microbodies. The reaction is inhibited by 2, 6, 8-trichloropurine, a competitive inhibitor of urate oxidase.


Author(s):  
N. J. Zaluzec

The ultimate sensitivity of microchemical analysis using x-ray emission rests in selecting those experimental conditions which will maximize the measured peak-to-background (P/B) ratio. This paper presents the results of calculations aimed at determining the influence of incident beam energy, detector/specimen geometry and specimen composition on the P/B ratio for ideally thin samples (i.e., the effects of scattering and absorption are considered negligible). As such it is assumed that the complications resulting from system peaks, bremsstrahlung fluorescence, electron tails and specimen contamination have been eliminated and that one needs only to consider the physics of the generation/emission process.The number of characteristic x-ray photons (Ip) emitted from a thin foil of thickness dt into the solid angle dΩ is given by the well-known equation


Author(s):  
V. Annamalai ◽  
L.E. Murr

Economical recovery of copper metal from leach liquors has been carried out by the simple process of cementing copper onto a suitable substrate metal, such as scrap-iron, since the 16th century. The process has, however, a major drawback of consuming more iron than stoichiometrically needed by the reaction.Therefore, many research groups started looking into the process more closely. Though it is accepted that the structural characteristics of the resultant copper deposit cause changes in reaction rates for various experimental conditions, not many systems have been systematically investigated. This paper examines the deposit structures and the kinetic data, and explains the correlations between them.A simple cementation cell along with rotating discs of pure iron (99.9%) were employed in this study to obtain the kinetic results The resultant copper deposits were studied in a Hitachi Perkin-Elmer HHS-2R scanning electron microscope operated at 25kV in the secondary electron emission mode.


Author(s):  
R. H. Morriss ◽  
J. D. C. Peng ◽  
C. D. Melvin

Although dynamical diffraction theory was modified for electrons by Bethe in 1928, relatively few calculations have been carried out because of computational difficulties. Even fewer attempts have been made to correlate experimental data with theoretical calculations. The experimental conditions are indeed stringent - not only is a knowledge of crystal perfection, morphology, and orientation necessary, but other factors such as specimen contamination are important and must be carefully controlled. The experimental method of fine-focus convergent-beam electron diffraction has been successfully applied by Goodman and Lehmpfuhl to single crystals of MgO containing light atoms and more recently by Lynch to single crystalline (111) gold films which contain heavy atoms. In both experiments intensity distributions were calculated using the multislice method of n-beam diffraction theory. In order to obtain reasonable accuracy Lynch found it necessary to include 139 beams in the calculations for gold with all but 43 corresponding to beams out of the [111] zone.


Author(s):  
John H. L. Watson ◽  
John L. Swedo ◽  
M. Vrandecic

The ambient temperature and the nature of the storage fluids may well have significant effects upon the post-implantation behavior of venus autografts. A first step in the investigation of such effects is reported here. Experimental conditions have been set which approximate actual operating room procedures. Saphenous veins from dogs have been used as models in the experiments. After removal from the dogs the veins were kept for two hours under four different experimental conditions, viz at either 4°C or 23°C in either physiological saline or whole canine arterial blood. At the end of the two hours they were prepared for light and electron microscopy. Since no obvious changes or damage could be seen in the veins by light microscopy, even with the advantage of tissue specific stains, it was essential that the control of parameters for successful grafts be set by electron microscopy.


Author(s):  
M. Iwatsuki ◽  
Y. Kokubo ◽  
Y. Harada

On accout of its high brightness, small optical source size, and minimal energy spread, the field emission gun (FEG) has the advantage that it provides the conventional transmission electron microscope (TEM) with a highly coherent illumination system and directly improves the resolving power and signal-to-noise ratio of the scanning electron microscope (SEM). The FEG is generally classified into two types; the cold field emission (C-FEG) and thermal field emission gun (T-FEG). The former, in which a field emitter is used at the room temperature, was successfully developed as an electron source for the SEM. The latter, in which the emitter is heated to the temperature range of 1000-1800°K, was also proved to be very suited as an electron source for the TEM, as well as for the SEM. Some characteristics of the two types of the FEG have been studied and reported by many authors. However, the results of the respective types have been obtained separately under different experimental conditions.


Sign in / Sign up

Export Citation Format

Share Document