Possible Utility of Middle Latency Responses in Electric Response Audiometry1

Author(s):  
H. Davis ◽  
S. K. Hirsh ◽  
L. L. Turpin
2013 ◽  
Vol 20 (2) ◽  
pp. 183-190 ◽  
Author(s):  
A. Barna ◽  
I. B. Földes ◽  
Z. Gingl ◽  
R. Mingesz

Abstract In experiments with short-pulse lasers the measurement control of the energy of the laser pulse is of crucial importance. Generally it is difficult to measure the amplitude of the pulses of short-pulse lasers using electronic devices, their response time being longer than the duration of the laser pulses. The electric response of the detector is still too fast to be directly digitized therefore a peak-hold unit can be used to allow data processing for the computer. In this paper we present a device which measures the energy of UV short (fs) pulses shot-byshot, digitizes and sends the data to the PC across an USB interface. The circuit is based on an analog peak detect and hold unit and the use of fiber optical coupling between the PC and the device provides a significant improvement to eliminate potential ground loops and to reduce conductive and radiated noise as well. The full development is open source and has been made available to download from our web page (http://www.noise.inf.u-szeged.hu/Instruments/PeakHold/).


2019 ◽  
Author(s):  
Johannes P. Dürholt ◽  
Babak Farhadi Jahromi ◽  
Rochus Schmid

Recently the possibility of using electric fields as a further stimulus to trigger structural changes in metal-organic frameworks (MOFs) has been investigated. In general, rotatable groups or other types of mechanical motion can be driven by electric fields. In this study we demonstrate how the electric response of MOFs can be tuned by adding rotatable dipolar linkers, generating a material that exhibits paralectric behavior in two dimensions and dielectric behavior in one dimension. The suitability of four different methods to compute the relative permittivity κ by means of molecular dynamics simulations was validated. The dependency of the permittivity on temperature T and dipole strength μ was determined. It was found that the herein investigated systems exhibit a high degree of tunability and substantially larger dielectric constants as expected for MOFs in general. The temperature dependency of κ obeys the Curie-Weiss law. In addition, the influence of dipolar linkers on the electric field induced breathing behavior was investigated. With increasing dipole moment, lower field strength are required to trigger the contraction. These investigations set the stage for an application of such systems as dielectric sensors, order-disorder ferroelectrics or any scenario where movable dipolar fragments respond to external electric fields.


Author(s):  
Michele Arigliani ◽  
Domenico M. Toraldo ◽  
Enrico Ciavolino ◽  
Caterina Lattante ◽  
Luana Conte ◽  
...  

To analyze the middle latency auditory evoked potential index (MLAEPi), compared to the standard bispectral index (BIS), as a method for evaluating the sedation level in drug-induced sleep endoscopy (DISE). In this controlled clinical study on a sample of 99 obstructive sleep apnea (OSA) or snoring patients, we compared the MLAEPi with the BIS after propofol infusion during the standard DISE technique in order to define the MLAEPi values within the observational window of the procedure. The DISE procedure was divided into eight steps, and we collected both MLAEPi and BIS data values from the same patient in every step. The MLAEPi showed a faster response than the BIS after propofol infusion during DISE. Therefore, the clinical use of the MLAEPi in evaluating the sedation level seems to be a good alternative to the current technological standards.


1988 ◽  
Vol 54 (1) ◽  
pp. 77-80 ◽  
Author(s):  
G.I. Groma ◽  
F. Ráksi ◽  
G. Szabó ◽  
G. Váró

1994 ◽  
Vol 19 (3) ◽  
pp. 171
Author(s):  
S. Dietrich ◽  
S. Barry ◽  
D. Parker

Sign in / Sign up

Export Citation Format

Share Document