Relevant Diagnostic Procedures in Renovascular Hypertension

Author(s):  
J. Rosenthal ◽  
I. Arlart ◽  
A. S. Nadjafi ◽  
J. Vollmar ◽  
H. E. Franz
Author(s):  
Bruce Mackay

The broadest application of transmission electron microscopy (EM) in diagnostic medicine is the identification of tumors that cannot be classified by routine light microscopy. EM is useful in the evaluation of approximately 10% of human neoplasms, but the extent of its contribution varies considerably. It may provide a specific diagnosis that can not be reached by other means, but in contrast, the information obtained from ultrastructural study of some 10% of tumors does not significantly add to that available from light microscopy. Most cases fall somewhere between these two extremes: EM may correct a light microscopic diagnosis, or serve to narrow a differential diagnosis by excluding some of the possibilities considered by light microscopy. It is particularly important to correlate the EM findings with data from light microscopy, clinical examination, and other diagnostic procedures.


Author(s):  
G. Mazzocchi ◽  
P. Rebuffat ◽  
C. Robba ◽  
P. Vassanelli ◽  
G. G. Nussdorfer

It is well known that the rat adrenal zona glomerulosa steroidogenic activity is controlled by the renin-angiotensin system. The ultrastructural changes in the rat zona glomerulosa cells induced by renovascular hypertension were described previously, but as far as we are aware no correlated biochemical and morphometric investigations were performed.Twenty adult male albino rats were divided into 2 experimental groups. One group was subjected to restriction of blood flow to the left kidney by the application of a silver clip about the left renal artery. The other group was sham-operated and served as a control. Renovascular hypertension developed in about 10 days: sistolic blood pressure averaged 165 ± 6. 4 mmHg, whereas it was about 110 ± 3. 8 mmHg in the control animals. The hypertensive and control rats were sacrificed 20 days after the operation. The blood was collected and plasma renin activity was determined by radioimmunological methods. The aldosterone concentration was radioimmunologically assayed both in the plasma and in the homogenate of the left capsular adrenal gland.


2000 ◽  
Vol 42 (9) ◽  
pp. 646-647 ◽  
Author(s):  
Hilary Espezel ◽  
Carolyn Graves ◽  
James E Jan ◽  
Anton Miller ◽  
Karin Renner ◽  
...  

1989 ◽  
Vol 8 (3) ◽  
pp. 517-540
Author(s):  
George H. Belhobek ◽  
Bradford J. Richmond ◽  
David W. Piraino ◽  
Harris Freed

2020 ◽  
Vol 59 (04) ◽  
pp. 294-299 ◽  
Author(s):  
Lutz S. Freudenberg ◽  
Ulf Dittmer ◽  
Ken Herrmann

Abstract Introduction Preparations of health systems to accommodate large number of severely ill COVID-19 patients in March/April 2020 has a significant impact on nuclear medicine departments. Materials and Methods A web-based questionnaire was designed to differentiate the impact of the pandemic on inpatient and outpatient nuclear medicine operations and on public versus private health systems, respectively. Questions were addressing the following issues: impact on nuclear medicine diagnostics and therapy, use of recommendations, personal protective equipment, and organizational adaptations. The survey was available for 6 days and closed on April 20, 2020. Results 113 complete responses were recorded. Nearly all participants (97 %) report a decline of nuclear medicine diagnostic procedures. The mean reduction in the last three weeks for PET/CT, scintigraphies of bone, myocardium, lung thyroid, sentinel lymph-node are –14.4 %, –47.2 %, –47.5 %, –40.7 %, –58.4 %, and –25.2 % respectively. Furthermore, 76 % of the participants report a reduction in therapies especially for benign thyroid disease (-41.8 %) and radiosynoviorthesis (–53.8 %) while tumor therapies remained mainly stable. 48 % of the participants report a shortage of personal protective equipment. Conclusions Nuclear medicine services are notably reduced 3 weeks after the SARS-CoV-2 pandemic reached Germany, Austria and Switzerland on a large scale. We must be aware that the current crisis will also have a significant economic impact on the healthcare system. As the survey cannot adapt to daily dynamic changes in priorities, it serves as a first snapshot requiring follow-up studies and comparisons with other countries and regions.


1987 ◽  
Vol 26 (06) ◽  
pp. 258-262
Author(s):  
J. Happi ◽  
R. P. Baum ◽  
J. Frohn ◽  
B. Weimer ◽  
A. Halbsguth ◽  
...  

The present study was done in order to examine if the use of111ln-DTPA- labeled MAb fragments in place of 131l-labeled MAb fragments increases the sensitivity of tomographic immunoscintigraphy to reach the level of that of planar imaging techniques. In 11 patients with various primary tumors, local recurrences or metastases [colorectal carcinoma (n = 7), ovarian carcinoma (n = 2), papillary thyroid carcinoma (n = 1), undifferentiated carcinoma of the lung (n = 1)], immunoscintigraphy (IS) was carried out using 111ln-DTPA- labeled F(ab’)2 fragments of various MAbs (anti-CEA, OC 125, anti-hTG) and planar and tomographic imaging were compared intraindividually. By conventional diagnostic procedures, the presence of a tumor mass was confirmed (transmission computer tomography, ultrasound) or verified (131l whole-body scintigraphy, histology) in all cases. Immunoscintigraphy was positive in 9 out of 11 cases by ECT and in 10 out of 11 cases by planar imaging. When using 111 In-labeled MAb fragments, intraindividual comparison of ECT and planar imaging resulted in a similar sensitivity. The increased sensitivity of ECT using this tracer in contrast to 131l-labeled MAb fragments may be attributed to the fact that the physical properties of111 In are much more suitable for the gamma cameras most commonly used (single detector, 3/8” crystal); using 111 In-labeled MAb fragments, count rates sufficient for ECT can be obtained within a reasonable acquisition time. This allows to combine IS with the advantages of ECT regarding tumour localization and prevention of artefacts due to superposition of background.


1982 ◽  
Vol 21 (01) ◽  
pp. 15-22 ◽  
Author(s):  
W. Schlegel ◽  
K. Kayser

A basic concept for the automatic diagnosis of histo-pathological specimen is presented. The algorithm is based on tissue structures of the original organ. Low power magnification was used to inspect the specimens. The form of the given tissue structures, e. g. diameter, distance, shape factor and number of neighbours, is measured. Graph theory is applied by using the center of structures as vertices and the shortest connection of neighbours as edges. The algorithm leads to two independent sets of parameters which can be used for diagnostic procedures. First results with colon tissue show significant differences between normal tissue, benign and malignant growth. Polyps form glands that are twice as wide as normal and carcinomatous tissue. Carcinomas can be separated by the minimal distance of the glands formed. First results of pattern recognition using graph theory are discussed.


Sign in / Sign up

Export Citation Format

Share Document