Constant Rate of CO Uptake with Variable Inspired CO Concentration

Author(s):  
Hazel A. Jones ◽  
P. D. Buckingham ◽  
J. C. Clark ◽  
R. E. Forster ◽  
J. D. Heather ◽  
...  
Author(s):  
A. De Veirman ◽  
J. Van Landuyt ◽  
K.J. Reeson ◽  
R. Gwilliam ◽  
C. Jeynes ◽  
...  

In analogy to the formation of SIMOX (Separation by IMplanted OXygen) material which is presently the most promising silicon-on-insulator technology, high-dose ion implantation of cobalt in silicon is used to synthesise buried CoSi2 layers. So far, for high-dose ion implantation of Co in Si, only formation of CoSi2 is reported. In this paper it will be shown that CoSi inclusions occur when the stoichiometric Co concentration is exceeded at the peak of the Co distribution. 350 keV Co+ ions are implanted into (001) Si wafers to doses of 2, 4 and 7×l017 per cm2. During the implantation the wafer is kept at ≈ 550°C, using beam heating. The subsequent annealing treatment was performed in a conventional nitrogen flow furnace at 1000°C for 5 to 30 minutes (FA) or in a dual graphite strip annealer where isochronal 5s anneals at temperatures between 800°C and 1200°C (RTA) were performed. The implanted samples have been studied by means of Rutherford Backscattering Spectroscopy (RBS) and cross-section Transmission Electron Microscopy (XTEM).


1950 ◽  
Vol 22 (7) ◽  
pp. 956-956 ◽  
Author(s):  
Lester Lundsted
Keyword(s):  

1986 ◽  
Vol 111 (4) ◽  
pp. 516-521
Author(s):  
Nina Clausen ◽  
Per-Eric Lins ◽  
Ulf Adamson ◽  
Bertil Hamberger ◽  
Suad Efendić

Abstract. Hypothyroidism has been alleged to modulate insulin action and influence the secretion of growth hormone and catecholamines. We recently investigated the influence of hypothyroidism on glucose counterregulatory capacity and the hormonal responses to insulin-induced hypoglycaemia in 6 patients with primary hypothyroidism (age 32–52 years, TSH-values 66–200 mU/l). Hypoglycaemia was induced in the hypothyroid state and again when the subjects were euthyroid. After an overnight fast a constant rate infusion of insulin (2.4 U/h) was given for 4 h. Glucose was measured every 15 min and insulin, C-peptide, glucagon, epinephrine, norepinephrine, growth hormone and cortisol every 30 min for 5 h. During insulin infusion somewhat higher concentrations of the hormone were obtained in the hypothyroid state and simultaneously glucose levels were 0.5 mmol/l lower. As expected, basal norepinephrine levels were higher in hypothyroidism. However, no increase in circulating norepinephrine during hypoglycaemia was registered in the two experiments. The responses of counterregulatory hormones showed an enhanced response of cortisol, similar responses of growth hormone and epinephrine while the glucagon response was paradoxically impaired. Our findings suggest that hypothyroidism alters insulin metabolism, and that the glucagon response to hypoglycaemia is impaired in this condition.


1973 ◽  
Vol 1 (2) ◽  
pp. 121-137 ◽  
Author(s):  
J. L. McCarty ◽  
T. J. W. Leland

Abstract The results from recent studies of some factors affecting tire braking and cornering performance are presented together with a discussion of the possible application of these results to the design of aircraft braking systems. The first part of the paper is concerned with steady-state braking, that is, results from tests conducted at a constant slip ratio or steering angle or both. The second part deals with cyclic braking tests, both single cycle, where brakes are applied at a constant rate until wheel lockup is achieved, and rapid cycling of the brakes under control of a currently operational antiskid system.


2019 ◽  
Author(s):  
Gede H Cahyana

Indoor air pollution in closed room is one of the air pollution that gives serious threats to human health. One of them come from vehicle gas emissions in closed parking area. This research identifies and analyses CO concentration measured in Mall X parking man’s breathing zone with closed parking area and in Mall Y semi-opened parking area. CO measurement carried out by passive sampling method using Personal Dosimeter Tubes. Measurement result of CO gas concentration to parking man’s breathing zone in Mall X was 25 – 81,25 ppm with average value in 50 ± 26,15 ppm. Meanwhile CO gas concentration in Mall Y gave result 3,13 – 12,5 ppm with average value in 7,88 ± 4,36 ppm. Correlation value between CO concentration and its intake in Mall X area was 0,9983, meanwhile correlation value between CO concentration and its intake in Mall Y area was 0,9903. It was concluded that CO gas concentration measured in parking man’s breathing zone influenced the differences of CO intake value in significance value.


Alloy Digest ◽  
1993 ◽  
Vol 42 (10) ◽  

Abstract CARPENTER GLASS SEALING 52 alloy has a virtually constant rate of thermal expansion to 1050 F. This datasheet provides information on composition, physical properties, hardness, elasticity, and tensile properties. Filing Code: FE-101. Producer or source: Carpenter.


1980 ◽  
Vol 45 (11) ◽  
pp. 2903-2918 ◽  
Author(s):  
Josef Horák ◽  
Zina Valášková ◽  
František Jiráček

Algorithms have been presented, analyzed and experimentally tested to stabilize the reaction temperature at constant inlet temperature and composition of the feed by controlled dispensing of the catalyst. The information for the control element is the course of the reaction temperature. If the temperature of the reaction mixture is below the set point, the catalyst is being fed into the reactor at a constant rate. If the reaction temperature is higher the catalyst dispenser is blocked; dispensing of the catalyst is not resumed until the set point temperature has been reached again. The amount of catalyst added is a function of the duration of the switching cycle. The effect has been discussed of the form of this function on the course of the switching cycle. The results have been tested experimentally on a laboratory reactor controlled in an unstable steady state.


1994 ◽  
Vol 59 (6) ◽  
pp. 1301-1304
Author(s):  
Jaroslav Nývlt ◽  
Stanislav Žáček

Lead iodide was precipitated by a procedure in which an aqueous solution of potassium iodide at a concentration of 0.03, 0.10 or 0.20 mol l-1 was stirred while an aqueous solution of lead nitrate at one-half concentration was added at a constant rate. The mean size of the PbI2 crystals was determined by evaluating the particle size distribution, which was measured sedimentometrically. The dependence of the mean crystal size on the duration of the experiment exhibited a minimum for any of the concentrations applied. The reason for this is discussed.


Sign in / Sign up

Export Citation Format

Share Document