Immunochemical Determination of Plasma Proteins

2015 ◽  
pp. 1197-1199
Author(s):  
H. G. Schwick
Antibiotics ◽  
2021 ◽  
Vol 10 (3) ◽  
pp. 298
Author(s):  
Alexander Ecke ◽  
Rudolf J. Schneider

Contamination of waters with pharmaceuticals is an alarming problem as it may support the evolution of antimicrobial resistance. Therefore, fast and cost-effective analytical methods for potential on-site analysis are desired in order to control the water quality and assure the safety of its use as a source of drinking water. Antibody-based methods, such as the enzyme-linked immunosorbent assay (ELISA), can be helpful in this regard but can also have certain pitfalls in store, depending on the analyte. As shown here for the class of β-lactam antibiotics, hydrolysis of the β‑lactam ring is a key factor in the immunochemical analysis as it influences antibody recognition. With the antibody used in this study, the limit of detection (LOD) in the immunoassay could be significantly reduced by hydrolysis for the five tested penicillins, with the lowest LOD for carbenicillin (0.2 nmol/L) and the greatest impact on penicillins G and V (reduction by 85%). In addition to enhanced quantification, our strategy also provides access to information about the degree of hydrolysis in water samples as shown for the most abundant penicillin amoxicillin.


1981 ◽  
Vol 27 (1) ◽  
pp. 149-152 ◽  
Author(s):  
M J Obregon ◽  
A Kurtz ◽  
R Ekins ◽  
G Morreale de Escobar

Abstract We assessed a commercial kit (Corning Medical) for "free" and total thyroxine determination, results being compared to those obtained by the Ekins and Ellis dialysis method (free thyroxine) and the method of Weeke and Orskov (total thyroxine). The kit procedure permits determination of both free and total thyroxine within 4 to 5 h, and the combined results may disclose changes in binding to plasma proteins that would be missed if only free thyroxine were determined. With both free-thyroxine methods, the values distinguished hyperthyroid patients from normal controls and pregnant women with 100% accuracy, but there was some overlap between hypothyroid patients and controls. Absolute values with the kit procedure often exceed those obtained by dialysis, especially for hypothyroid patients and pregnant women. We conclude that the kit may be of as much diagnostic value as the dialysis method if the limitations regarding absolute values are kept in mind and the test is not used as a substitute for thyrotropin determinations in cases of suspected hypothyroidism.


1950 ◽  
Vol 3 (3) ◽  
pp. 248-259 ◽  
Author(s):  
E. J. King ◽  
R. V. Coxon
Keyword(s):  

2015 ◽  
Author(s):  
Αιμιλία Ψαρούλη

Recent developments in the fields of bioanalytical chemistry and microelectronics have resulted in a growing trend of transferring the classical analytical methods from the laboratory bench to the field through the development of portable devices or microsystems based on biosensors. Biosensors are self-contained integrated devices capable to provide analytical information using biological recognition molecules in direct spatial contact with a transducer. Biosensors using antibodies or antigens as biological recognition elements are termed as immunosensors and they are based on the same principle as the classical solid-phase immunoassays.The aim of this thesis was to develop and evaluate an optical immunosensor based on Mach-Zehnder Interferometry and integrated on silicon substrate for the immunochemical determination of clinical analytes. The optical sensor developed is fabricated entirely by mainstream silicon technology by the Optical Biosensors group of the Institute of Nanoscience and Nanotechnology of NCSR “Demokritos” and combines arrays of ten sensors in a single silicon chip. Each sensor consists of an integrated on silicon light source that emits a broad spectrum in visible-near ultraviolet range and it is coupled to an integrated silicon nitride waveguide which has been patterned into Mach-Zehnder interferometer. The signal is recorded either through a photodetector monolithically integrated onto the same silicon chip (fully integrated configuration) or through an external spectrometer (semi-integrated configuration). In the fully integrated configuration, the signal recorded is the total photocurrent across the whole spectral range, while in semi-integrated configuration the whole transmission spectrum is continuously recorded and is mathematically transformed (Fourier Transform) to phase shift. As in the classical Mach-Zehnder interferometers, the waveguide in the proposed sensor is split into two arms, the sensing one which is appropriately modified with recognition biomolecule and the reference arm that is covered by a protective layer. The specific binding of the analyte with the immobilized onto the surface recognition biomolecule causes an effective refractive index change at the surface of the sensing arm thus affecting the phase of the waveguided light with respect to the reference arm. Thus, when the two arms converge again, an interference spectrum is generated that is altered during bioreaction providing the ability of monitoring in real-time and without using labels. The main difference of the sensor developed with respect to classical Mach-Zehnder interferometers is that the light source is monolithically integrated on the same silicon substrate with the waveguides and the waveguided light is not monochromatic, but broad spectrum.At first in this study, the method for chemical activation of biofunctionalization of chips was optimized. It was found that the highest signals were obtained when chips where activated by (3-aminopropyl)triethoxysilane and deposition of biomolecules solutions using a microarray spotter. Then, a comparison of the two sensor configurations, i.e. the fully and the semi-integrated configuration was performed using a model binding assay namely the streptavidin-biotin reaction. Semi-integrated configuration provided higher detection sensitivities mainly due to lower between-sensor signal variation in the same chip and between different chips. Thus, this configuration was selected for further evaluation with respect to the determination of analytes of clinical interest and especially of immunochemical determination of C-reactive protein in human serum samples. CRP is a marker of inflammation widely used in everyday clinical practice for diagnosis and therapy monitoring of inflammatory situations. Nevertheless, CRP has been also proposed as a prognostic marker of myocardial infraction and three risk levels have been established; low risk for serum CRP concentrations < 1 μg/mL; medium risk for concentrations in the range 1-3 μg/mL; and high risk for concentrations >3 μg/mL. In the frame of the present thesis, enzyme immunoassays for the determination of CRP in microtitration plates both competitive and non-competitive were developed in order to select the most appropriate reagents and define the immunoassay conditions. Then both assay format were transferred and evaluated on the sensor. It was found that the non-competitive format offered higher responses and ability for regeneration of immobilized onto the sensor antibody against CRP and was therefore selected for the final sensor evaluation. The assay developed following the competitive format was sensitive and accurate as was demonstrated through recovery and dilution linearity experiments, and provided for analysis of samples with a wide range of CRP concentrations since it was immune to the presence of serum. In addition, the CRP values determined with the immunosensor developed in serum samples from unknown donors were in good agreement with those determined for the same samples by commercially available kits and instruments showing the reliability of the determinations performed with the immunosensor developed and its potential for analysis of clinical samples.


1989 ◽  
Vol 63 (5) ◽  
pp. 361-366 ◽  
Author(s):  
Riitta Mustonen ◽  
P�ivi Hietanen ◽  
Sinikka Lepp�l� ◽  
Mervi Takala ◽  
Kari Hemminki

Biochemistry ◽  
1982 ◽  
Vol 21 (8) ◽  
pp. 1794-1806 ◽  
Author(s):  
Janice A. Nagy ◽  
Yvonne C. Meinwald ◽  
Harold A. Scheraga

Sign in / Sign up

Export Citation Format

Share Document