A Novel Real-Time Multiplex Reverse Transcriptase-Polymerase Chain Reaction for the Detection of HIV-1 RNA by Using Dual-Specific Armored RNA as Internal Control

Intervirology ◽  
2008 ◽  
Vol 51 (1) ◽  
pp. 42-49 ◽  
Author(s):  
Jie Huang ◽  
Chang-Mei Yang ◽  
Lu-Nan Wang ◽  
Shuang Meng ◽  
Wei Deng ◽  
...  
2021 ◽  
Vol 80 (Suppl 1) ◽  
pp. 1379.1-1379
Author(s):  
L. Giardullo ◽  
C. Rotondo ◽  
A. Corrado ◽  
N. Maruotti ◽  
R. Colia ◽  
...  

Background:Previous study evidenced a cross-reactivity between Sars-Cov-2 antibodies and autoimmune tissue antigen involved in connective tissue diseases, as nuclear antigen (NA), extractable nuclear antigen (ENA), histone and collagen (1). No study has been published about the titer of Sars-Cov-2 antibodies in non-infected patients with autoimmune disease.Objectives:To evaluate the titer of SARS-CoV-2 antibodies in non-COVID-19 patients and compare it between systemic sclerosis (SSc) patients and healthy controls (HC).Methods:A total of 58 patients with SSc (who fulfilled ACR/EULAR 2013 SSc classification criteria) and 18 HC were enrolled. Sera of all participants were collected, and SARS-CoV-2 antibodies (IgG and IgM) were evaluated by means ELISA. In all participants swabs for SARS-CoV-2 by real-time reverse-transcriptase-polymerase-chain-reaction assay were reported negative. Demographic, clinical, and autoimmune serological characteristics of SSc patients were recorded. The normal distribution was assessed using the Shapiro–Wilk’s test. Exclusion criteria was previous or actual Sars-Cov-2 infection. Comparisons between study groups of patients were evaluated by the Student’s t-test or Mann – Whitney U-test as appropriate. The differences between categorial variables were assessed by Pearson chi-square or Fisher’s exact test, as opportune. Statistical significance was set at p ≤ 0.05.Results:We observed significant differences between SSc patients and HC in serum levels of Sars-Cov-2 antibodies (IgG: 1,4±2,1 AU/ml vs 0,36±0,19 AU/ml respectively (p=0,001); and IgM: 2,5±3,1 AU/ml vs 0,8±0,7 AU/ml (p=0,022)). In 5 SSc patients was found titer of Sars-Cov-2 antibodies (IgG) exceeding the cut-off, but the control of swabs for SARS-CoV-2 by real-time reverse-transcriptase-polymerase-chain-reaction assay were negative. No significative differences in Sars-Cov-2 autoantibodies titer were found in subgroup of SSc patients with or without ILD or PAH, limited or diffuse skin subset, and different autoantibodies profile. Furthermore, antibodies titer was not associated with different drugs (steroid, methotrexate, mofetil-mycophenolate and bosentan) in use.Conclusion:A cross mimicking between Sars-Cov-2 antibodies and antinuclear antibodies or anti ENA could be hypothesized. Further studies are necessary to unravel the reliability of Sars-Cov-2 antibodies detection in autoimmune disease.References:[1]Vojdani, A., Vojdani, E., & Kharrazian, D. (2021). Reaction of human monoclonal antibodies to SARS-CoV-2 proteins with tissue antigens: Implications for autoimmune diseases. Frontiers in Immunology, 11, 3679Disclosure of Interests:None declared


Author(s):  
Rajeev Kumar Jain ◽  
Nagaraj Perumal ◽  
Rakesh Shrivastava ◽  
Kamlesh Kumar Ahirwar ◽  
Jaya Lalwani ◽  
...  

Introduction: The whole world is facing an ongoing global health emergency of COVID-19 disease caused by the Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2). Real-Time Reverse Transcription-Polymerase Chain Reaction (RT-PCR) is a gold standard in the detection of SARS-CoV-2 infection. Presently, many single tube multiple gene target RT-PCR kits have been developed and are commercially available for Coronavirus Disease 2019 (COVID-19) diagnosis. Aim: To evaluate the performance of seven COVID-19 RT-PCR kits (DiagSure, Meril, VIRALDTECT II, TruPCR, Q-line, Allplex and TaqPath) which are commercially available for COVID-19 RT-PCR diagnosis. Materials and Methods: This observational study was conductedat the State Virology Laboratory (SVL), Gandhi Medical College, Bhopal, Madhya Pradesh, India. Seven commercially available kits have been evaluated on the basis of: (i) number of SARS-CoV-2 specific gene target; (ii) human housekeeping genes as internal control; (iii) RT-PCR run time; and (iv) kit performances to correctly detect SARS-CoV-2 positive and negative RNA samples. A total of 50 RNA samples (left over RNA) were included, master mix preparation, template addition and RT-PCR test has been performed according to kits literature. At the end of PCR run, mean and standard deviation of obtained cut-off of all kits were calculated using Microsoft Excel. Results: All seven RT-PCR kits performed satisfactory regarding the reproducibility and they could correctly identify 30 positive and 20 negative RNA samples. RNA samples (group C) having low viral loads with a high Cycle threshold (Ct) value (>30) were also detected by all these seven kits. Obtained Ct values of each group was in parallel range in comparison with the initial testing Ct values. Kits were found to be superior which contains primers and probes for three SARS-CoV-2 specific gene targets, have human housekeeping gene as internal control and taking less time to complete RT-PCR. Conclusion: All seven COVID-19 RT-PCR kits included in this study demonstrated satisfactory performance and can be used for the routine molecular diagnosis of COVID-19 disease.


Sign in / Sign up

Export Citation Format

Share Document