The IS6110 Repetitive DNA Element of Mycobacterium tuberculosis Is Not Detected in Exhaled Breath Condensate of Patients with Active Pulmonary Tuberculosis

Respiration ◽  
2007 ◽  
Vol 74 (3) ◽  
pp. 329-333 ◽  
Author(s):  
Rupali Jain ◽  
Christopher A. Schriever ◽  
Larry H. Danziger ◽  
Sang Hyun Cho ◽  
Israel Rubinstein
Antioxidants ◽  
2021 ◽  
Vol 10 (10) ◽  
pp. 1572
Author(s):  
Silvia Guzmán-Beltrán ◽  
Laura Elena Carreto-Binaghi ◽  
Claudia Carranza ◽  
Martha Torres ◽  
Yolanda Gonzalez ◽  
...  

Tuberculosis (TB) is one of the highest infectious burdens worldwide. An excess of inflammation and inadequate antioxidant defense mechanisms are believed to lead to chronic inflammation and lung damage in tuberculosis (TB). However, circulating metabolites do not always replicate lung-associated biomarkers that define the pathobiology of the disease. The objective of this study was to determine the utility of exhaled breath condensate (EBC), a non-invasive and straightforward sample, to evaluate alveolar space-derived metabolites of redox state and inflammation. We assessed the levels of exhaled oxidant/antioxidant parameters (8-isoprostane, MDA, GSH), inflammatory markers, such as nucleosomes, cytokines (IL-2, IL-4, IL-6 and IL-8, IL-10, GM-CSF, TNF-α, and IFN-γ) and lipid mediators (PGE2, LTB4, RvD1, and Mar1), in patients with recently diagnosed pulmonary TB and healthy controls’ EBC and serum. The TB patients showed 36% lower GSH levels, and 2-, 1.4-, 1.1-, and 50-fold higher levels of 8-isoprostanes, nucleosomes, IL-6, and LTB4, respectively, in EBC. There was no correlation between EBC and serum, highlighting the importance of measuring local biomarkers. Quantitation of local inflammatory molecules and redox states in EBC would help find biomarkers useful for pharmacological and follow-up studies in pulmonary tuberculosis.


2018 ◽  
Vol 44 (3) ◽  
pp. 256-266 ◽  
Author(s):  
Don R. Bergfelt ◽  
John Lippolis ◽  
Michel Vandenplas ◽  
Sydney Davis ◽  
Blake A. Miller ◽  
...  

2020 ◽  
Vol 16 (7) ◽  
pp. 872-879
Author(s):  
Samin Hamidi

Background: Abuse of drugs is associated with several medical, forensic, toxicology and social challenges. “Drugs of abuse” testing is therefore an important issue. Objective: We propose a simple CE-based method for the quantification of amphetamine, codeine and morphine after direct injection of Exhaled Breath Condensate (EBC) by the aid of simple stacking mode and an off-line pre-concentration method. Methods: Using graphene oxide adsorbents, amphetamine, codeine and morphine were extracted from EBC in order to eliminate the proteins and other interferences. In addition to off-line method, an online stacking mode was applied to improve the analytical signal obtained from the instrument. Results: The validation parameters were experimented on the developed method based on the FDA guideline over concentration ranges of 12.5-100, 30-500 and 10-1250 ng/mL associated with amphetamine, codeine and morphine, respectively. Small volumes (around 100 μL) of EBC were collected using a lab-made setup and successfully analyzed using the proposed method where precisions and accuracies (within day and between days) were in accordance with the guideline (recommended less than 15 % for biological samples). The recovery tests were used to evaluate the matrix effect and data (94 to 105 %) showed that the proposed method can be applied in different EBC matrix samplings of subjects. Conclusion: The proposed method is superior for simultaneous determination of amphetamine, codeine and morphine over chromatographic analyses because it is fast and consumes fewer chemicals, with no derivatization step.


2020 ◽  
Vol 16 (8) ◽  
pp. 1032-1040
Author(s):  
Laleh Samini ◽  
Maryam Khoubnasabjafari ◽  
Mohamad M. Alimorad ◽  
Vahid Jouyban-Gharamaleki ◽  
Hak-Kim Chan ◽  
...  

Background: Analysis of drug concentrations in biological fluids is required in clinical sciences for various purposes. Among other biological samples, exhaled breath condensate (EBC) is a potential sample for follow up of drug concentrations. Methods: A dispersive liquid-liquid microextraction (DLLME) procedure followed by a validated liquid chromatography method was employed for the determination of budesonide (BDS) in EBC samples collected using a homemade setup. EBC is a non-invasive biological sample with possible applications for monitoring drug concentrations. The proposed analytical method is validated according to the FDA guidelines using EBC-spiked samples. Its applicability is tested on EBC samples collected from healthy volunteers receiving a single puff of BDS. Results: The best DLLME conditions involved the use of methanol (1 mL) as a disperser solvent, chloroform (200 μL) as an extraction solvent, and centrifugation rate of 3500 rpm for 5 minutes. The method was validated over a concentration range of 21-210 μg·L-1 in EBC. Inter- and intra-day precisions were less than 10% where the acceptable levels are less than 20%. The validated method was successfully applied for the determination of BDS in EBC samples. Conclusion: The findings of this study indicate that the developed method can be used for the extraction and quantification of BDS in EBC samples using a low cost method.


2019 ◽  
Vol 15 (5) ◽  
pp. 535-541 ◽  
Author(s):  
Fariba Pourkarim ◽  
Ali Shayanfar ◽  
Maryam Khoubnasabjafari ◽  
Fariborz Akbarzadeh ◽  
Sanaz Sajedi-Amin ◽  
...  

Background:Developing a simple analysis method for quantification of drug concentration is one of the essential issues in pharmacokinetic and therapeutic drug monitoring studies.Objective:A fast and reliable dispersive liquid-liquid microextraction procedure was employed for preconcentration of verapamil in exhaled breath condensate (EBC) samples and this was followed by the determination with high-performance liquid chromatography-ultraviolet detection.Methods:A reverse-phase high-performance liquid chromatography (RP-HPLC) combined with a dispersive liquid-liquid microextraction method (DLLME) was applied for quantification of verapamil in the EBC samples. The developed method was validated according to FDA guidelines.Results:Under the optimum conditions, the method provided a linear range between 0.07 and 0.8 µg.mL-1 with a coefficient of determination of 0.998. The intra- and inter-day relative standard deviation and relative error values of the method were below 15%, which indicated good precision and accuracy. The proposed method was successfully applied for the analysis of verapamil in two real samples with concentrations of 0.07 and 0.09 µg.mL-1.Conclusion:The established HPLC-UV-DLLME method could be applied for the analysis of verapamil in human EBC samples.


2019 ◽  
Vol 75 (2) ◽  
pp. 65-69 ◽  
Author(s):  
Chieh-Ming Wu ◽  
Anna Adetona ◽  
Chi (Chuck) Song ◽  
Luke Naeher ◽  
Olorunfemi Adetona

Author(s):  
Tiago Azenha Rama ◽  
Inês Paciência ◽  
João Cavaleiro Rufo ◽  
Diana Silva ◽  
Pedro Cunha ◽  
...  

2021 ◽  
Vol 40 (4) ◽  
pp. S63
Author(s):  
E. Ibáñez-Martínez ◽  
M. López-Nogueroles ◽  
M. Alcoriza-Balaguer ◽  
I. Pérez ◽  
M. Roca-Marugán ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document