scholarly journals Comparison of the Ability of Two Brands of CBCT with That of SEM to Detect the Marginal Leakage of Class V Composite Resin Restorations

2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Mitra Karbasi Kheir ◽  
Leili Khayam

Objectives. This study was carried out to compare the ability of two common brands of cone-beam computed tomography (CBCT), including New Tom and Planmeca, to detect the marginal leakage of class V composite resins. The ability of each of the two brands of CBCT to detect the marginal leakage of class V composite resins was also compared with that of scanning electron microscopy (SEM). Methods. Class V cavities were prepared on the buccal surface of sixteen extracted caries-free human premolars. Cavities were conditioned and filled with composite resin. The teeth were immersed in 50% weight/weight aqueous silver nitrate solution for 24 hours. They were then taken out and rinsed with distilled water. Next, they were put in a developing solution. They were first viewed with New Tom and Planmeca CBCT units and were then sectioned and evaluated by an SEM. Results. The results of the Wilcoxon signed-rank test showed no significant difference between the mean marginal leakage scores of New Tom and Planmeca CBCT images ( p value = 0.157) and between those of New Tom CBCT and SEM images ( p value = 0.098). However, there was a significant difference between the mean marginal leakage scores of Planmeca CBCT and SEM images ( p value = 0.023). Conclusion. There were no significant differences between New Tom and Planmeca CBCT units in the detection of marginal leakage of class V composite resins. However, when these CBCT units were compared with the SEM, the New Tom CBCT unit could detect the marginal leakage better than Planmeca.

2003 ◽  
Vol 50 (2) ◽  
pp. 59-64 ◽  
Author(s):  
Larisa Blazic ◽  
Slavoljub Zivkovic

The purpose of this study was to evaluate the marginal microleakage in Class II with different materials in resin composite restorations cured by using "soft start" and standard polymerization techniques. Two adhesive Class II cavities were prepared in 50 human teeth with enamel in-between. Samples were divided into 5 groups and filled with composite resins, compatible flow resin composites and bonding systems. The ocluso-mesial restorations were cured with standard curing technique, and the ocluso-distal restorations were cured with "soft start" curing technique. After thermocycling, the teeth were immersed in silver nitrate solution and sectioned for leakage evaluation. The results pointed out, after "soft start" and standard curing techniques, that the best marginal behavior in Class II restorations was obtained with Tetric Ceram / Tetric Flow composite resins, then with Filtek Z 250 / Filtek Flow, followed by Admira Admira Flow and Point / Revolution composite materials. The deepest dye penetration was found in cavities with Diamond Lite / Diamond Link composite restorations. No statistically significant difference was found in the tested composite resin restorations, whether treated with "soft start" polymerization or with standard polymerization technique, in regard to marginal micro leakage.


2004 ◽  
Vol 12 (4) ◽  
pp. 307-311 ◽  
Author(s):  
Silvia Kenshima ◽  
Rosa Helena Miranda Grande ◽  
Julio da Motta Singer ◽  
Rafael Yagüe Ballester

The objective of this study was to evaluate in vitro the effect on leakage of two incremental filling techniques and two composite resins with different elastic modulus and similar polymerization shrinkage. Eighty Class V cavities (4x4x2mm) were prepared in bovine incisors and were randomly restored with Z-250 (Z) or Durafill VS (D) + Single Bond in axial (a) or oblique (o) increments. The restorations were divided into two groups: Not Aged - N (4-hour-storage in water at 37ºC) and Aged - A (1-week storage in water at 37ºC + 1000 x - 5º-55ºC / 1-min dwell time). The specimens were covered with 2 coats of nail varnish so that only the restoration margins were exposed to silver nitrate 50% (2h) and developed under fluorescent light (8h). After they were sectioned twice in buccal-lingual direction, the four exposed surfaces were digitized (Vidcap) and the silver nitrate penetration was measured (ImageLab) at the incisal and gingival walls. Data were analyzed by a 3-way ANOVA (Resin, Filling Technique and Aging) separately for incisal and gingival walls (alpha=0.05). Resin and Aging were statistically significant either for the incisal and the gingival walls. The microfill composite resin infiltrated more than the hybrid composite. The thermal cycling caused an overall increase in silver nitrate penetration. The filling technique affected leakage depending on the composite resin and aging regimen.


2014 ◽  
Vol 17 (2) ◽  
pp. 27
Author(s):  
Thays Regina Costa ◽  
Lucielle Cristina Cecchin ◽  
Alessandro Dourado Loguercio ◽  
Alessandra Reis

<p><strong>Objective:</strong> The durability of bonded interface between silorane (SIL) and methacrylate-based (MET) composite resins wasn’t investigated yet. The purpose was to evaluate the repair strength (RS) and nanoleakage of the SIL repair using silorane- or methacrylate-based materials immediately [IM] or after 6 months of water storage [6M]. <strong>Materials and Methods:</strong> fifteen resin blocks (Filtek P90, 3MESPE) were polished, sandblasted with 50-µm aluminum oxide sandblasting and cleaned with 37% phosphoric acid. Then the specimens were divided into three groups: SIL-SIL (adhesive and composite resin); SIL-MET (silorane adhesive and methacrylate based composite) and MET-MET (methacrylate-based adhesive and composite resin) were used for the repair. Composite-composite bonded sticks (0.9 mm<sup>2</sup>) were sectioned and divided to be tested in tension (1.0 mm/min) IM or 6M. Two sticks from each tooth, at each time, were immersed in a 50% silver nitrate solution and evaluated by SEM. Data were analyzed by two-way repeated measures ANOVA and Tukey´s tests. <strong>Results:</strong> The RS of the SIL was not dependent upon the adhesive and composite used for the repair. A significant reduction of the RS was observed for all groups after 6M. <strong>Conclusions:</strong> Both materials can be used for the repair of the silorane composite, despite degradation occur after 6M.</p>


Author(s):  
Soodabeh Kimyai ◽  
Narmin Mohammadi ◽  
Mahmoud Bahari ◽  
Elahe Pesyanian ◽  
Farhood Pesyanian

Objectives: This in-vitro study aimed to evaluate the effect of cavity disinfection with chlorhexidine (CHX) on marginal gaps of Class V composite resin restorations bonded with a universal adhesive using self-etch and etch-and-rinse bonding strategy. Materials and Methods: Sixty sound human premolars were randomly assigned to two groups (n=30): group 1 (CHX) and group 2 (no CHX). Each group was divided into two subgroups (n=15) according to the bonding strategy of the universal adhesive (self-etch or etch-and-rinse). Class V cavities were prepared on the buccal surfaces of the teeth. The occlusal and gingival margins of the cavities were placed in enamel and dentin, respectively. In the first and second subgroups of both groups, the All-Bond Universal adhesive was applied with self-etch and etch-and-rinse bonding strategy, respectively. After restoration and thermocycling, the samples were sectioned, and marginal gaps at the gingival margins were measured in micrometer (µm) under a stereomicroscope. Two-way analysis of variance (ANOVA) was used to compare marginal gaps between the groups and the subgroups. Results: The mean marginal gap size was significantly affected by cavity disinfection (P=0.001) and bonding strategy (P=0.002). However, the interaction effect of these two factors on the mean marginal gap size was not significant (P=0.79). Conclusion: The use of CHX resulted in larger marginal gaps at the gingival margins of Class V composite resin restorations. Irrespective of disinfection, the self-etch bonding strategy resulted in larger marginal gaps compared to the etch-and-rinse bonding strategy.


2021 ◽  
Vol 11 (1) ◽  
pp. 42
Author(s):  
Syarifah Nadhira Assyafira Al-Habsyi ◽  
Kun Ismiyatin ◽  
Galih Sampoerno

Background: Tooth discoloration can be treated with dental bleaching using Hydrogen peroxide (H2O2). Dental bleaching may interfere with the shear bond strength of composite resins because the remaining free radicals can affect bonding polymerization. Epigallocatcehin-3-gallate (EGCG) as an antioxidant can neutralize the free radicals produced during bleaching process. Purpose: Analyze the role of EGCG antioxidants in increasing the shear bond strength of composite resin after bleaching.. Reviews: Of the seven journals included in this literature review, six journals reported significant difference, and one journal noted no significant difference in the shear bond strength of composite resin following the EGCG application. Conclusion: The use of EGCG can increase the shear bond strength value of post-bleaching composite resin restorations. 


2010 ◽  
Vol 10 (3) ◽  
Author(s):  
Angela C. C. Zuanon ◽  
Ticiana S. O. Capote

Due to doubts related to the application and association of techniques for appropriate adhesion, as the air abrasion system and last generation adhesive systems, the objective of this study was to evaluate the marginal leakage in Class V composite restorations in permanent teeth prepared with rotating instruments and then submitted to air abrasion and adhesive systems. Cavities were prepared with burs in high speed in facial and lingual surfaces of 25 human third molars. The specimens were divided into 5 groups of 10 preparations each: G1 (air abrasion and Scotchbond Multi Purpose), G2 (phosphoric acid and Scotchbond MP), G3 (Clearfil SE Bond self-etching system), G4 (air abrasion, phosphoric acid and Scotchbond MP) G5 (air abrasion and Clearfil SE Bond). All groups were restored with Z100 composite resin. The teeth were subjected to thermal cycling and immerged in 50% silver nitrate solution. After sectioning, the specimens were analyzed with a stereomicroscope for assessment of microleakage according to the degree of dye penetration. The Kruskal-Wallis test followed by Dunn Multiple Comparison test were performed in order to evaluate the differences among the experimental groups. Air abrasion groups demonstrated the greatest leakage. Scotchbond MP with phosphoric acid produced the least leakage, with greater leakage in gingival margins than occlusal margins in all experimental groups. It was concluded that dentin treatment with air abrasion should not be used in permanent teeth to reduce the marginal leakage.


2019 ◽  
Vol 21 (1) ◽  
pp. 46
Author(s):  
Públio Juliana do Carmo ◽  
Lúcia Trazzi Prieto ◽  
Cíntia Tereza Pimenta Araújo ◽  
Josué Junior Araujo Pierote ◽  
Débora Alves Nunes Leite Lima ◽  
...  

O objetivo deste estudo foi avaliar a rugosidade superficial de resinas compostas à base silorano e metacrilato submetidas a diferentes técnicas de acabamento/polimento. Foram preparadas 12 amostras de disco de cada resina composta: P90®, Z350® e Carisma, divididas em 12 grupos de acordo com a técnica de acabamento / polimento: sem acabamento / polimento (controle); acabamento com ponta diamantada 1112 FF; acabamento com ponta diamantada 1112 FF associada a Enhance / Pogo; acabamento com ponta diamantada 1112 FF associada a Enhance / Pogo / Polishing / Pastas Poli I e II / Fotogloss. Após as leituras iniciais da rugosidade da superfície, os espécimes foram submetidos a ciclos mecânicos (1.200.000 ciclos) e submetidos imediatamente a leituras de rugosidade final. As medias de rugosidade superfícial foram analisadas estatisticamente por ANOVA e teste de Tukey-Kramer (α = 0,05). As imagens de MEV foram realizadas após o acabamento / polimento e após a ciclagem mecânica. O compósito P90 mostrou valores de rugosidade superficial semelhantes a outros compósitos investigados. Tough, mostrou diferença significativa nas técnicas de acabamento / polimento. O grupo de pontas damantadas apresentou maior rugosidade superficial que diferiu das outras resinas compostas (α <0,05). Enance / Pogo mostrou os menores resultados, que não apresentaram diferença em relação ao grupo de pasta de polimento (α> 0,05). O material restaurador posterior de baixa contração apresentou rugosidade superficial semelhante quando comparado as resinas compostas de dimetacrilato e são restaurações adequadas para região posterior.Palavras-chave: Dente. Resinas de Silorano.  Propriedades de Superfície. AbstractThe aim of this study was to evaluate the surface roughness of a silorane and methacrylate-based composite resins subjected to different finishing/polishing techniques. Twelve disk specimens were prepared from each composite resin: P90®, Z350® and Charisma, divided into 12 groups according to the finishing/polishing technique: no finishing/polishing (control); finishing with 1112 FF diamond burs; finishing with 1112 FF diamond burs associated to Enhance/Pogo; finishing with 1112 FF diamond burs associated to Enhance/Pogo/Polishing/Poli I and II pastes/Fotogloss. After initial readouts of surface roughness, the specimens were subjected to mechanical cycling (1.200.000 cycles) and immediately subjected to final roughness readouts.  Surface roughness means was statistically analyzed by ANOVA and Tukey-Kramer test (α=0.05). SEM images were realized after finishing/polishing and after mechanical cycling. The P90 composite showed surface roughness values similar to other investigated composites. However, significant difference was observed in finishing/polishing techniques. The diamond burs group showed the highest surface roughness differing from the other composite resins (α < 0.05). Enance/Pogo showed the lowest results, which presented no difference compared to the polishing paste group (α > 0.05). The low-shrink posterior restorative showed similar surface roughness when compared to dimethacrylate composite resins and suitable to posterior restorations. Keywords: Tooth. Silorane Resins. Surface Properties. 


2020 ◽  
Vol 14 (1) ◽  
pp. 19-25 ◽  
Author(s):  
Mohammad Esmaeel Ebrahimi Chaharom ◽  
Mahmoud Bahari ◽  
Leila Safyari ◽  
Hossein Safarvand ◽  
Hajar Shafaei ◽  
...  

Background . Due to the effect of pre-heating on the degree of conversion of composite resins and the possible effect on cytotoxicity, the effect of pre-heating of bulk-fill composite resins was investigated on cytotoxicity in this study. Methods. In this study, three different types of composite resin were used, including Tetric N-Ceram Bulk-Fil, Xtrafil, and Xtrabase. From each composite resin, 10 cylindrical samples (5 mm in diameter and 4 mm in height) were prepared, with five samples preheated to 68°C, and the other five samples polymerized at room temperature (25°C). Twenty-four hours after polymerization, cytotoxicity was assessed by MTT assay on human fibroblasts. Statistical analysis of data was carried out with two-way ANOVA and Sidak Post-Hoc. The significance level of the test was determined at 0.05. Results. There was no statistically significant difference between the mean percentage of cytotoxicity in terms of pre-heating (P>0.05), but the cytotoxicity of the studied composite resins was significantly different (P<0.001). The cytotoxicity of Tetric N-Ceram Bulk-fil composite resin was higher than that of the two other composite resins. Conclusion. Pre-heating of bulk-fill composite resin did not affect their cytotoxicity. In addition, the cytotoxicity of different bulk-fill composite resins was not the same.


Author(s):  
Sari Dewiyani ◽  
Denissa Zahra S.

At dental clinic, there are some obstacles which occasionally may occur. A dentist runs out of the same brand of the composite resin and bonding material during tooth restoration, so they would have to be paired with material of the diffrent brand. Certain things that may occur during tooth restoration is polymerization shrinkage which forms a gap that could reducing edge density. This research is using packable nanohybrid type A composite resin and packable nanohybrid type B resin composite with total etch bonding on Class V restoration with the thin cervical section of enamel. Aim: This research is to explain the differences between two types of packable nanohybrid composite resins with total etch bonding in Class V microleakage. Methods: This research will use an experimental laboratory method with 32 maxillary premolars that have been prepared in Class V, which divided into 2 groups, group A and group B. Methylene blue will be used for the measurements, whereas the microscope will be used for the observation. Furthermore, data analysis would be conducted using the Mann Whitney U Test Method. Results: The research showed that there was a significant difference between group A and group B, which is p <0.05. Conclusion: According to this research, it can be seen that group B showed less leakage compared to group A.


2021 ◽  
Vol 11 (1) ◽  
pp. 28
Author(s):  
Ferriza Tri Mardianti ◽  
Sukaton Sukaton ◽  
Galih Sampoerno

Background: Composite resins restoration is a treatment for tooth structure loss due to pathological conditions. Longevity of composite resins restoration can be affected by surface hardness restoration. Glycerin can increase surface hardness restoration with inhibit bond oxygen and free radicals on polymerization composite resins. Purpose: Analyze the increase surface hardness composite resins restoration after glycerin application before light-curing composite resins. Review(s): Of the six journals included in this literature review, five journals reported significant differences because of the obstacles in the polymerization process of the composite resin when composite contact with light-curing will activate the photoinitiator to produce highly reactive free radicals, free radicals will break the double chain carbon bonds of monomers and form single bonds of free radicals with monomers. Bonding of free radicals with monomers will produce polymeric bonds (degree of conversion) which affects the level of surface hardness of the filling. While one journal noted no significant difference in the surface hardness of composite resin after glycerin application. Conclusion: The use of glycerin before light-curing can increase the surface hardness composite resin restorations.


Sign in / Sign up

Export Citation Format

Share Document