scholarly journals What Radiologist Should Know about MRI Translational Forces and Hazard: An Ex-Vivo Simulation of Retained Metallic Shrapnel

2021 ◽  
Vol 2021 ◽  
pp. 1-5
Author(s):  
Ali Kanj ◽  
Ibrahim Ghosn ◽  
Assaad Mohanna ◽  
Georges Rouhana

Background. In a country immersed in endless rounds of wars, retained metallic foreign bodies remain a significant dilemma in the daily practice of every Lebanese radiologist. When a shrapnel’s hazard is of concern, the decision between performing or refusing a justified MRI exam is not always straightforward. In this small trial, we aimed to better understand the shrapnel’s MRI safety by mimicking our daily practice. Methods. Five shrapnel with an incremental increase in their long axis were put in an animal flesh and then introduced into a 3 T magnetic field. The behavior of each shrapnel was concretely assessed by performing before and after magnetic field exposure CT acquisitions. Results. Translation along the z-axis ranged from 0.9 mm to 2.8 mm. Torque angle ranged between 2.8 and 54 degrees with an average of 15.62 degrees. Conclusions. Shrapnel’s movements in the magnetic field are not negligible during the acute phase of injury where there is no reinforcing fibroblastic reaction and invite us to reconsider the MRI safety of these metallic foreign bodies. Standard radiographs may be sufficient, but a targeted CT scan may be of better value for a confident decision for assessment of shrapnel position near viscera and major vessels.

1992 ◽  
Vol 68 (05) ◽  
pp. 500-505 ◽  
Author(s):  
Ch M Samama ◽  
Ph Bonnin ◽  
M Bonneau ◽  
G Pignaud ◽  
E Mazoyer ◽  
...  

SummaryWe investigated the comparative antithrombotic properties of clopidogrel, an analogue of ticlopidine, and aspirin, using the Folts' model on femoral arteries in 22 pigs. On each animal, clopidogrel or aspirin were used to treat the thrombotic process on the left femoral artery and to prevent this process on the right femoral artery. Sequentially: an injury and stenosis were carried out on the left femoral artery; the thrombotic process was monitored with a Doppler during a 30-min observation period for cyclic flow reductions or permanent cessation of flow; after the first cyclic flow reduction occurred, clopidogrel (5 mg kg-1) or aspirin (2.5, 5, 100 mg kg-1) were injected intravenously; if cyclic flow reductions were abolished, epinephrine (0.4 µg kg-1 min-1) was injected to try to restore cyclic flow reductions and/or permanent cessation of flow; then injury and stenosis were applied on the right femoral artery. Before and after injection of clopidogrel or aspirin, ear immersion bleeding times and ex-vivo platelet aggregation were performed. Clopidogrel (n = 7) abolished cyclic flow reductions in all animals and epinephrine did not restore any cyclic flow reduction. On the right femoral artery, cyclic flow reductions were efficiently prevented, even for two injuries. Basal bleeding time (5 min 28) was lengthened (>15 min, 30 min after clopidogrel and remained prolonged even after 24 h). ADP-induced platelet aggregation was inhibited (more than 78%). Comparatively, aspirin had a moderate and no dose-dependent effect. Aspirin 2.5 mg kg-1 (n = 6) abolished cyclic flow reductions in 2 animals, CFR reoccurred spontaneously in one animal and epinephrine restored it in a second animal. Aspirin 5 mg kg-1 (n = 6) abolished cyclic flow reductions in only 3 animals and epinephrine always restored it. Aspirin 100 mg kg-1 (n = 3) was unable to abolish cyclic flow reductions. On the right femoral artery, aspirin did not significantly prevent cyclic flow reductions which occurred in all animals after one (n = 14) or two injuries (n = 1), except for one animal. Basal bleeding time was lengthened but it shortened rapidly, reaching its basal value after 24 h. ADP-induced aggregation was not significantly inhibited, whereas arachidonic acid induced aggregation was always inhibited. Clopidogrel appears as a more potent antithrombotic drug than aspirin in this model, in treating and preventing spontaneous or epinephrine-induced cyclic flow reductions and lengthening bleeding time.


1991 ◽  
Vol 65 (05) ◽  
pp. 504-510 ◽  
Author(s):  
Raffaele De Caterina ◽  
Rosa Sicari ◽  
Walter Bernini ◽  
Guido Lazzerini ◽  
Giuliana Buti Strata ◽  
...  

SummaryTiclopidine (T) and aspirin (ASA) are two antiplatelet drugs both capable of prolonging bleeding time (BT), with a different mechanism of action. A synergism in BT prolongation has been reported and is currently considered an argument for not recommending their combination. However, a profound suppression of platelet function might be a desirable counterpart of a marked prolongation of BT, with a possible use in selected clinical situations. We therefore studied ex vivo platelet function (aggregation by ADP 0.5-1-2.5 μM; adrenaline 0.75-2.5 μM; collagen 1.5-150 μg/ml; arachidonic acid 1 mM; PAF 1 μM; adrenaline 0.17 μM + ADP 0.62 μM; serum thromboxane ([TX]B2 generation) and BT (Mielke) in 6 patients with stable coronary artery disease receiving such combination. Patients underwent sequential laboratory evaluations at baseline, after 7 days of T 250 mg b.i.d., before and after the intravenous administration of ASA 500 mg, respectively, and, finally, after a minimum of 7 days of sole ASA oral administration (50 mg/day). The experimental design, therefore, allowed a comparison of T and ASA effects (2nd and 4th evaluation), and an assessment of the combination effect (3rd evaluation). Platelet aggregation in response to all doses of ADP was depressed more by T than by ASA. Conversely, responses to adrenaline, and arachidonate were affected more by ASA than by T. For all other agents, differences were not significant. T + ASA combination was more effective (p <0.05) than either treatment alone in depressing responses to high-dose collagen (% over control, mean ± SEM: T: 95 ± 3; ASA: 96 ± 5; T + ASA: 89 ± 4). Serum TXB2 (basal, ng/ml: 380 ± 54) did not change with T (372 ± 36), dropped to <1 ng/ml on ASA injection and slightly re-increased to 9.1 ± 3.1 ng/ml on oral low-dose ASA. BT (basal 7.4 ± 0.6 min) was affected similarly by T (9.2 ± 0.8) or ASA (9.7 ± 0.9) alone, but increased to 15.0 ± 0.7 min on combination treatment (106% increase over control). Thus, the strong synergism in BT prolongation by ASA-T combination has a counterpart in the inhibition of platelet function in response to strong stimuli such as high-dose collagen, not otherwise affected significantly by single-drug treatment. This effect is a possible rationale for the clinical evaluation of T + ASA combination.


1995 ◽  
Vol 14 (3) ◽  
pp. 193-197 ◽  
Author(s):  
Laurence Bonhomme-Faivre ◽  
Ernest Bizi ◽  
Sylvie Marion ◽  
Yvonnick Bezie ◽  
Eric Rudant ◽  
...  

2020 ◽  
Vol 26 (6) ◽  
pp. 667-670
Author(s):  
Thomas Larrew ◽  
Mohammed Alshareef ◽  
Robert F. Murphy ◽  
Ramin Eskandari ◽  
Libby Kosnik Infinger

OBJECTIVEAlthough the advent of magnetic growing rod technology for scoliosis has provided a means to bypass multiple hardware lengthening operations, it is important to be aware that many of these same patients have a codiagnosis of hydrocephalus with magnet-sensitive programmable ventricular shunts. As the magnetic distraction of scoliosis rods has not previously been described to affect the shunt valve setting, the authors conducted an investigation to characterize the interaction between the two devices.METHODSIn this ex vivo study, the authors carried out 360 encounters between four different shunt valve types at varying distances from the magnetic external remote control (ERC) used to distract the growing rods. Valve settings were examined before and after every interaction with the remote control to determine if there was a change in the setting.RESULTSThe Medtronic Strata and Codman Hakim valves were found to have setting changes at distances of 3 and 6 inches but not at 12 inches. The Aesculap proGAV and Codman Certas valves, typically described as MRI-resistant, did not have any setting changes due to the magnetic ERC regardless of distance.CONCLUSIONSAlthough it is not necessary to check a shunt valve after every magnetic distraction of scoliosis growing rods, if there is concern that the magnetic ERC may have been within 12 inches (30 cm) of a programmable ventricular shunt valve, the valve should be checked at the bedside with a programmer or with a skull radiograph along with postdistraction scoliosis radiographs.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Rafat Damseh ◽  
Yuankang Lu ◽  
Xuecong Lu ◽  
Cong Zhang ◽  
Paul J. Marchand ◽  
...  

AbstractRecent studies suggested that cerebrovascular micro-occlusions, i.e. microstokes, could lead to ischemic tissue infarctions and cognitive deficits. Due to their small size, identifying measurable biomarkers of these microvascular lesions remains a major challenge. This work aims to simulate potential MRI signatures combining arterial spin labeling (ASL) and multi-directional diffusion-weighted imaging (DWI). Driving our hypothesis are recent observations demonstrating a radial reorientation of microvasculature around the micro-infarction locus during recovery in mice. Synthetic capillary beds, randomly- and radially-oriented, and optical coherence tomography (OCT) angiograms, acquired in the barrel cortex of mice (n = 5) before and after inducing targeted photothrombosis, were analyzed. Computational vascular graphs combined with a 3D Monte-Carlo simulator were used to characterize the magnetic resonance (MR) response, encompassing the effects of magnetic field perturbations caused by deoxyhemoglobin, and the advection and diffusion of the nuclear spins. We quantified the minimal intravoxel signal loss ratio when applying multiple gradient directions, at varying sequence parameters with and without ASL. With ASL, our results demonstrate a significant difference (p < 0.05) between the signal-ratios computed at baseline and 3 weeks after photothrombosis. The statistical power further increased (p < 0.005) using angiograms measured at week 4. Without ASL, no reliable signal change was found. We found that higher ratios, and accordingly improved significance, were achieved at lower magnetic field strengths (e.g., B0 = 3T) and shorter echo time TE (< 16 ms). Our simulations suggest that microstrokes might be characterized through ASL-DWI sequence, providing necessary insights for posterior experimental validations, and ultimately, future translational trials.


2021 ◽  
pp. 875647932110332
Author(s):  
Patrick J. Fish

Intraocular foreign bodies (IOFB) present differently depending on the type of material (wood, glass, metal) for the IOFB, extent of the injury, and location of the injury. IOFB and the injury can cause a perforation or penetration of the globe which can require more extensive treatment including surgery. Proper evaluation of the IOFB and injury can help to determine extent of the injury, the prognosis of the vision, and health of the eye before and after treatment but may be difficult for the physician depending on the view of the posterior chamber being compromised by media or simply by patient sensitivity. The extent of the injury may also prevent proper evaluation due to swelling, lacerations on the lids, or pain. Proper ophthalmic sonography can provide a quick evaluation of the globe for any IOFB in both the outpatient setting as well as emergency department setting. Evaluation via sonography may allow the physician to accurately diagnose and properly treat the patient to help restore and prevent further loss of vision.


Author(s):  
Lisa Repsold ◽  
Roger Pool ◽  
Mohammed Karodia ◽  
Gregory Tintinger ◽  
Piet Becker ◽  
...  