scholarly journals Study on Acoustic Characteristics of a Flexible Plate Strongly Coupled with Rectangular Cavity

2021 ◽  
Vol 2021 ◽  
pp. 1-14
Author(s):  
Jinlong Liao ◽  
Haichao Zhu ◽  
Jiuxiao Hou ◽  
Suwei Yuan

This paper presents a method to predict the acoustic characteristics and steady-state responses of a flexible plate strongly coupled with rectangular cavity based on energy principle theory and Legendre polynomial series. First, the displacement of the plate and the sound pressure in the cavity are constructed in the form of two-dimensional and three-dimensional Legendre polynomial series, respectively. The unknown expansion coefficients are obtained using the Rayleigh–Ritz technique based on the energy expressions for the strongly coupled plate-cavity system. The accuracy, convergence, and efficiency of the present method are verified by comparing with the results available in the FEM and literature. Finally, the effects of the structural boundary conditions, cavity depth, and structural length-width ratio on the coupling natural frequency and the steady-state responses under three excitation conditions are analyzed.

2002 ◽  
Vol 13 (04) ◽  
pp. 205-224 ◽  
Author(s):  
Andrew Dimitrijevic ◽  
Sasha M. John ◽  
Patricia Van Roon ◽  
David W. Purcell ◽  
Julija Adamonis ◽  
...  

Multiple auditory steady-state responses were evoked by eight tonal stimuli (four per ear), with each stimulus simultaneously modulated in both amplitude and frequency. The modulation frequencies varied from 80 to 95 Hz and the carrier frequencies were 500, 1000, 2000, and 4000 Hz. For air conduction, the differences between physiologic thresholds for these mixed-modulation (MM) stimuli and behavioral thresholds for pure tones in 31 adult subjects with a sensorineural hearing impairment and 14 adult subjects with normal hearing were 14 ± 11, 5 ± 9, 5 ± 9, and 9 ± 10 dB (correlation coefficients .85, .94, .95, and .95) for the 500-, 1000-, 2000-, and 4000-Hz carrier frequencies, respectively. Similar results were obtained in subjects with simulated conductive hearing losses. Responses to stimuli presented through a forehead bone conductor showed physiologic-behavioral threshold differences of 22 ± 8, 14 ± 5, 5 ± 8, and 5 ± 10 dB for the 500-, 1000-, 2000-, and 4000-Hz carrier frequencies, respectively. These responses were attenuated by white noise presented concurrently through the bone conductor.


2001 ◽  
Vol 112 (3) ◽  
pp. 555-562 ◽  
Author(s):  
M.Sasha John ◽  
Andrew Dimitrijevic ◽  
Terence W Picton

2018 ◽  
Vol 39 (2) ◽  
pp. 260-268 ◽  
Author(s):  
Maaike Van Eeckhoutte ◽  
Robert Luke ◽  
Jan Wouters ◽  
Tom Francart

Sign in / Sign up

Export Citation Format

Share Document