scholarly journals Influence of Dentin Priming with Tannin-Rich Plant Extracts on the Longevity of Bonded Composite Restorations

2021 ◽  
Vol 2021 ◽  
pp. 1-10
Author(s):  
Mackeler Ramos Polassi ◽  
Thales de Sá Oliveira ◽  
Ana Calheiros de Carvalho ◽  
Lívia Soman de Medeiros Medeiros ◽  
Thiago André Moura Veiga ◽  
...  

Objective. This in vitro study evaluated the influence of bioactive plant extracts as dentin biomodifying agents to improve the longevity of bonded restorations. For that, plant extracts were applied to the dentin surface prior to the adhesive system. Materials and Methods. Bovine incisors were ground flat to obtain 2 mm thick slices in which conical preparations were made (N = 10). Tannin-containing plant extracts were applied to dentin before the application of the restorative system, as follows: control group (untreated, CTL), chlorhexidine 0.12% (CHX), mastruz (Dysphania ambrosioides, MTZ), cat’s claw (Uncaria tomentosa, CTC), guarana (Paullinia cupana, GUA), galla chinensis (Rhus chinensis, GCH), and tannic acid (extracted from Acacia decurrens, TNA). The push-out bond strength test was conducted (0.5 mm/min). Dentin biomodification was assessed by the modulus of elasticity and mass change in bovine tooth sections (0.5 × 1.7 × 7.0 mm). The dentin staining after extract treatments of dentin slices was compared. The dentin surface wettability was also evaluated by means of the contact angles of the adhesive system with the dentin surface and compared with the untreated control group. Data were subjected to ANOVA/Tukey’s test (α = 0.05). Results. The bond strength of the restoratives to dentin was not significantly improved by the plant extracts, irrespective of the evaluation time ( p > 0.05 ). Except for TNA, the elastic modulus of demineralized dentin significantly reduced after treatment with the plant extracts ( p < 0.05 ). The dentin staining correlated with the tannin content of the extracts. The contact angle was significantly reduced when treated with CTC, GCH, and TNA. Conclusions. The tannin-containing extracts had a questionable effect on the longevity of bonded restorations. The dentin modulus was negatively affected by the extract treatments. Although some of the extracts changed the contact angle, which seems to improve the adhesive monomer permeation, the tannin-rich plant extract application prior to adhesive application was proven to be clinically unfeasible due to dentin staining.

2021 ◽  
Vol 37 ◽  
pp. e37005
Author(s):  
Laerte Ribeiro Menezes-Júnior ◽  
Marcos Alan Vieira Bittencourt ◽  
Andomar Bruno Fernandes Vilela ◽  
Carlos José Soares ◽  
Diego Figueiredo Nóbrega ◽  
...  

This study aimed to analyze the shear bond strength (SBS) of ceramic orthodontic brackets bonded with two different adhesive systems to intact and eroded teeth. Ceramic brackets were bonded to 72 bovine central incisors divided into four groups, defined by two study factors: enamel condition (control group, kept in artificial saliva; and experimental group, eroded by using immersion cycles in Coke™ for 90 seconds, every six hours for five days), and adhesive system type (Transbond™ XT or Transbond™ Plus Color Change). Polycrystalline ceramic brackets were adhesively fixed on all specimens using the same light curing protocol. SBS was tested using 0.5 mm/min and the failure mode was classified. SBS data was analyzed using two-way ANOVA followed by Tukey test. The adhesive remnant index (ARI) scores were analyzed using Kruskal-Wallis test with Dunn's post-hoc pairwise comparison (α=0.05). Percentages of ARI scores between the groups were compared by Fisher’s exact test. Spearman's correlation coefficient was applied to investigate the correlation between ARI scores and SBS values. Only the adhesive system factor had significant effect on SBS (p=0.014), Transbond™ Plus Color Change showing higher values. No significance was found for enamel condition (p=0.665) or the interaction between adhesive system and enamel condition (p=0.055). ARI scores frequencies differed between groups (p<0.001). The median ARI scores were statistically different for most comparisons among the groups. However, no significant correlation was found between ARI scores and SBS. In conclusion, the type of adhesive system affected the SBS of ceramic brackets to dental enamel, but the enamel condition, intact or eroded, had no significant effect. There was no correlation between ARI scores and SBS values, although eroded enamel tended to retain more adhesive after bracket removal.


2008 ◽  
Vol 02 (02) ◽  
pp. 086-090 ◽  
Author(s):  
Hale Ară ◽  
Nazmiye Dönmez ◽  
Sema Belli

ABSTRACTObjectives: The purpose of this in vitro study was to evaluate the effect of artificial saliva contamination on microtensile bond strength to pulp chamber dentin.Methods: Clearfil SE Bond (SEB) (Kuraray, JAPAN) adhesive system and Clearfil Photo Posterior (CPP) (Kuraray, JAPAN) composite resin were used. Twenty extracted caries-free human molar teeth were randomly distributed into four groups. Apart from a control group without contamination (Group 1), primed dentin surfaces were contaminated with artificial saliva (10 s), rinsed, dried, reprimed and bonded (Group 2), coated with adhesive, contaminated with artificial saliva, rinsed, dried, bonding procedures were repeated (Group 3), coated with adhesive, light cured, contaminated with saliva, rinsed, dried, treated with SE primer (SEP) and SEB (Group 4).After 24 hrs, the teeth were prepared for microtensile bond testing and tensile bond strength was measured (1mm/min). The data was calculated as MPa and analyzed using one-way ANOVA and Duncan test (P<.05).Results: The results indicated that Group 2 showed lowest bond strength when compared to the others (P<.05). No statistically significant difference was found between Groups 3 and 4 (P>.05).Conclusions: It was concluded that contamination during priming procedure has a negative effect on bond strength (P<.05). Although contamination of the uncured adhesive was not critical in this study (P>.05) any kind of contamination of the bonding area should, in principle, be avoided. (Eur J Dent 2008;2:86-90)


2013 ◽  
Vol 18 (3) ◽  
pp. 101-106 ◽  
Author(s):  
Sissy Maria Mendes Machado ◽  
Diego Bruno Pinho do Nascimento ◽  
Robson Costa Silva ◽  
Sandro Cordeiro Loretto ◽  
David Normando

OBJECTIVE: To evaluate in vitro the effects of tooth whitening using gel with Amorphous Calcium Phosphate (ACP) on the bond strength of metal brackets. METHODS: Thirty-six bovine incisors were sectioned at the crown-root interface, and the crowns were then placed in PVC cylinders. The specimens were divided into 3 groups (n = 12) according to whitening treatment and type of gel used, as follows: G1 (control) = no whitening; G2 = whitening with gel not containing ACP (Whiteness Perfect - FGM), G3 = whitening with gel containing ACP (Nite White ACP - Discus Dental). Groups G2 and G3 were subjected to 14 cycles of whitening followed by an interval of 15 days before the bonding of metal brackets. Shear bond strength testing was performed on a Kratos universal test machine at a speed of 0.5 mm/min. After the mechanical test, the specimens were assessed to determine the adhesive remnant index (ARI). The results were subjected to ANOVA, Tukey's test and Kruskal-Wallis test (5%). RESULTS: Significant differences were noted between the groups. Control group (G1 = 11.10 MPa) showed a statistically higher shear bond strength than the groups that underwent whitening (G2 = 5.40 Mpa, G3 = 3.73 MPa), which did not differ from each other. There were no significant differences between the groups in terms of ARI. CONCLUSION: Tooth whitening reduces the bond strength of metal brackets, whereas the presence of ACP in the whitening gel has no bearing on the results.


2012 ◽  
Vol 17 (4) ◽  
pp. 1-7 ◽  
Author(s):  
Roberto Hideo Shimizu ◽  
Karlos Giovani Grando ◽  
Isabela Almeida Shimizu ◽  
Augusto Ricardo Andriguetto ◽  
Ana Cláudia Moreira Melo ◽  
...  

OBJECTIVE: This in vitro study was designed to evaluate the shear bond strength (SBS) of orthodontic metal brackets bonded by direct and indirect techniques. METHODS: Thirty healthy human maxillary premolar teeth were used. The teeth were divided into three groups of 10 teeth each: Group I - indirect bonding with SondhiTM Rapid-Set system (3M/Unitek), Group II - indirect bonding with TransbondTM XT adhesive system (3M/Unitek) and Group III - direct bonding with TransbondTM XT adhesive system (3M/Unitek). After bonding and obtaining the specimens for the study, the specimens were subjected to SBS testing in a universal testing machine (Emic, model DL-500). The Kolmogorov-Smirnov test was applied to ascertain that the data had a normal distribution and the Bartlett test to check whether there was homogeneity of variance. One-factor analysis of variance was performed and, subsequently, Tukey's test for paired means. A 5% significance level was adopted. RESULTS: The results of Group I were 67.6 (N) and 5.9 (MPa); Group II, 68.9 (N) and 6.1 (MPa) and Group III (control), 92.5 (N) and 8.1 (MPa). CONCLUSION: It can therefore be concluded that the means for Group III were significantly higher compared with Groups I and II in both Newton (N) and Megapascal (MPa) values. The means attained by the indirect bonding technique used in Groups I and II, however, exhibited no statistically significant differences.


2019 ◽  
Vol 13 (4) ◽  
pp. 305-310
Author(s):  
Mina Biria ◽  
Sajedeh Namaei Ghasemi ◽  
Seyedeh Mahsa Sheikh-Al-Eslamian ◽  
Narges Panahandeh

Background. This in vitro study aimed to evaluate the microshear bond strength (μSBS), microhardness and morphological characteristics of primary enamel after treating with sodium fluoride (NaF) and acidulated phosphate fluoride (APF). Methods. Forty-eight primary canines were cut into mesial and distal sections and assigned to five groups randomly: group 1 (immersed in saliva as a control), group 2 (treated with NAF and immersed in saliva for 30 minutes), group 3 (treated with APF and immersed in saliva for 30 minutes), group 4 (treated with NAF and immersed in saliva for 10 days), and group 5 (treated with APF and immersed in saliva for 10 days). Composite resin (Filtek Z250) was bonded on the specimens (n=15) for measuring the μSBS. After storage in 37°C artificial saliva for 24 hours, µSBS and Vickers hardness tests (10 readings) were performed. The data were analyzed using one-way ANOVA and Kolmogorov-Smirnov, Levene’s and Tukey HSD tests (P<0.05). Morphological analysis of enamel and modes of failure were carried out under a scanning electron microscope (SEM) on two remaining specimens. Results. Significant differences in μSBS were only noted between groups 2 and 4 (P=0.024). Group 3 showed a significant decrease in hardness after storage in artificial saliva (P<0.001), with a significantly lower hardness than the other groups (P<0.001). The SEM observations showed irregular particles in groups 3 and 5; uniform, smooth and thin coats were seen in groups 2 and 4. Conclusion. Fluoride therapy with NaF and APF gels prior to restorative treatments had no adverse effects on the microshear bond strength.


2020 ◽  
Vol 2020 ◽  
pp. 1-7
Author(s):  
Sabra Jaâfoura ◽  
Amira Kikly ◽  
Saida Sahtout ◽  
Mounir Trabelsi ◽  
Dorra Kammoun

Introduction. This in vitro study compared the shear strength of three composite resin systems to fluorosed and normal dentin. Methods. Silorane FiltekTM P90, FiltekTMZ250 XT in combination with the adhesive system AdperTM Single bond 2, and Amelogen® Plus in association with Peak Universal Bond® were tested. Fifteen normal and 15 fluorosed dentine disks were prepared per material. The shear bond strength test was performed using a universal machine. Results. One-way ANOVA revealed significant differences in bond strength between the tested composite resins. All tested materials had significantly different adhesion at the fluorosed and the nonfluorosed interface. FiltekTM Z250 XT and Silorane had lower adhesion values to fluorosed than to normal dentin. In contrast, Amelogen® Plus presented a better average resistance at the fluorosed interface. Conclusion. Amelogen® Plus presented a better average shear bond strength on the fluorosed dentine. FiltekTMZ250 XT showed the best adhesion forces and shear bond strength with sound dentine. Further studies are needed to better understand the sealing of these systems.


2020 ◽  
Vol 24 (1) ◽  
pp. 21-28
Author(s):  
Ediz Kale ◽  
Ayça Deniz İzgi ◽  
Remzi Niğiz

SummaryBackground/Aim: The purpose of this in-vitro study was to compare the resin-bonded fixed partial dentures (RBFPD) fabricated using two different structural designs and two different antibacterial adhesive lutting protocols in regard to their resistance to debonding.Material and Methods: Forty samples for a model with single missing molar were divided into 4 groups (M1, M2, C1, C2) (n=10). M1 and M2 were prepared in accordance with modified inlay slot-cavity retained RBFPD design; C1 and C2 were prepared according to conventional inlay slot-cavity retained RBFPD design. M1 and C1 cavities were treated with 2% chlorhexidine-based (CHX) cavity disinfectant and 10-methacryloyloxydecyl dihydrogen phosphate (MDP) containing adhesive system; M2 and C2 cavities were treated with MDP and 12-methacryloyloxydodecylpyridinium bromide (MDPB) containing adhesive system featuring antibacterial cavity cleansing effect. The RBFPDs were made of base-metal alloy and their fit surfaces sandblasted with aluminium oxide (Al2O3). Adhesive resin cement was used for cementation, and the RBFPD retainers were interlocked into their corresponding inlay cavities using composite resin. After 1 week being immersed in aqueous environment, the RBFPDs were subjected to tensile loading at a crosshead speed of 1 mm/min until failure. One way ANOVA and Tukey HSD tests were used for statistical evaluation (α=0.05). Mode of failure and tooth damage was also noted.Results: Mean tensile bond strength values were 356 N for M1, 305 N for M2, 467 N for C1, and 455 N for C2. Tensile strength values of C1 and C2 were significantly higher than those of M1 and M2 (p<0.05). The mode of failure was mostly adhesive in character at the metal-cement interface in all groups. Tooth fracture was observed nearly in all specimens. No significant difference was detected between the antibacterial adhesive lutting protocols (p>0.05).Conclusions: The RBFPDs with the conventional design were found to be more retentive than those with the modified design. Using an adhesive system featuring antibacterial properties with no need of separate antibacterial agent application during bonding may be favourable.


PeerJ ◽  
2016 ◽  
Vol 4 ◽  
pp. e2458 ◽  
Author(s):  
Bruna Raquel Zancopé ◽  
Vanessa B. Dainezi ◽  
Marinês Nobre-dos-Santos ◽  
Sillas Duarte ◽  
Vanessa Pardi ◽  
...  

BackgroundA carbon dioxide (CO2) laser has been used to morphologically and chemically modify the dental enamel surface as well as to make it more resistant to demineralization. Despite a variety of experiments demonstrating the inhibitory effect of a CO2laser in reduce enamel demineralization, little is known about the effect of surface irradiated on bacterial growth. Thus, this in vitro study was preformed to evaluate the biofilm formation on enamel previously irradiated with a CO2laser (λ = 10.6 µM).MethodsFor this in vitro study, 96 specimens of bovine enamel were employed, which were divided into two groups (n = 48): 1) Control-non-irradiated surface and 2) Irradiated enamel surface. Biofilms were grown on the enamel specimens by one, three and five days under intermittent cariogenic condition in the irradiated and non-irradiated surface. In each assessment time, the biofilm were evaluated by dry weigh, counting the number of viable colonies and, in fifth day, were evaluated by polysaccharides analysis, quantitative real time Polymerase Chain Reaction (PCR) as well as by contact angle. In addition, the morphology of biofilms was characterized by fluorescence microscopy and field emission scanning electron microscopy (FESEM). Initially, the assumptions of equal variances and normal distribution of errors were conferred and the results are analyzed statistically by t-test and Mann Whitney test.ResultsThe mean of log CFU/mL obtained for the one-day biofilm evaluation showed that there is statistical difference between the experimental groups. When biofilms were exposed to the CO2laser, CFU/mL and CFU/dry weight in three day was reduced significantly compared with control group. The difference in the genes expression (Glucosyltransferases (gtfB) and Glucan-binding protein (gbpB)) and polysaccharides was not statically significant. Contact angle was increased relative to control when the surface was irradiated with the CO2laser. Similar morphology was also visible with both treatments; however, the irradiated group revealed evidence of melting and fusion in the specimens.ConclusionIn conclusion, CO2laser irradiation modifies the energy surface and disrupts the initial biofilm formation.


2005 ◽  
Vol 16 (2) ◽  
pp. 107-111 ◽  
Author(s):  
Eduardo Batista Franco ◽  
Lawrence Gonzaga Lopes ◽  
Paulo Henrique Perlatti D'Alpino ◽  
José Carlos Pereira

The purpose of this study was to investigate the effect of pH of different adhesive systems on the polymerization of a chemically cured composite resin (Adaptic - AD), by means of tensile bond strength testing. The adhesive systems tested were: ARM, Prime & Bond 2.1 (PB), Scotchbond Multi Purpose (SMP) and Single Bond (SB). Bond strength at the resin/adhesive system/resin interface was assessed. Five groups (n=5) were formed, according to following configuration: G1: AD/ARM/AD; G2: AD/PB/AD; G3: AD/SMP/AD; G4: AD/SB/AD; G5: AD/AD (no adhesive). A two-mold stainless steel matrix with a cone-shaped opening (1-mm-thick; 4 mm in diameter) was used to obtain resin discs. AD resin was inserted into the first mold, left-self curing and an adhesive layer was applied onto resin surface and light-cured. The second mold was assembled over the first and was filled with the resin. After 10 min, this setting was loaded in tension in a universal testing machine running at a crosshead speed of 0.5 mm/min. Data were submitted to one-way ANOVA and Tukey's test (p<0.05). Bond strength means (kgf) were: G1: 15.23 ± 4.1; G2: 0.00 ± 0.0; G3: 16.96 ± 2.4; G4: 10.08 ± 2.7; G5: 15.44 ± 0.9. There were statistically significant differences (p<0.05) between G2-G1; G2-G3; G2-G4; G4-G1; G4-G3. The systems with the lowest pHs (PB and SB) yielded the lowest bond strength. The findings of this in vitro study demostrates that the pH of adhesive systems influences the polymerization and bond strength of chemically cured resin materials. The low pH simplified adhesive systems showed distinct degrees of incompatibility with the chemically cured resin, when compared to the conventional adhesive systems.


2016 ◽  
Vol 2016 ◽  
pp. 1-10 ◽  
Author(s):  
Andreas Hellak ◽  
Jennifer Ebeling ◽  
Michael Schauseil ◽  
Steffen Stein ◽  
Matthias Roggendorf ◽  
...  

Objective.The aim of this in vitro study was to determine the shear bond strength (SBS) and adhesive remnant index (ARI) score of two self-etching no-mix adhesives (iBond™and Scotchbond™) on different prosthetic surfaces and enamel, in comparison with the commonly used total etch system Transbond XT™.Materials and Methods. A total of 270 surfaces (1 enamel and 8 restorative surfaces,n=30) were randomly divided into three adhesive groups. In group 1 (control) brackets were bonded with Transbond XT primer. In the experimental groups iBond adhesive (group 2) and Scotchbond Universal adhesive (group 3) were used. The SBS was measured using a Zwicki 1120™testing machine. The ARI and SBS were compared statistically using the Kruskal–Wallis test (P≤0.05).Results. Significant differences in SBS and ARI were found between the control group and experimental groups.Conclusions. Transbond XT showed the highest SBS on human enamel. Scotchbond Universal on average provides the best bonding on all other types of surface (metal, composite, and porcelain), with no need for additional primers. It might therefore be helpful for simplifying bonding in orthodontic procedures on restorative materials in patients. If metal brackets have to be bonded to a metal surface, the use of a dual-curing resin is recommended.


Sign in / Sign up

Export Citation Format

Share Document