scholarly journals Effect of Marginal Designs on Fracture Strength of High Translucency Monolithic Zirconia Crowns

2020 ◽  
Vol 2020 ◽  
pp. 1-10
Author(s):  
Niwut Juntavee ◽  
Sasiprapa Kornrum

Introduction. Monolithic zirconia is able to achieve certain aesthetic, but its durability in resisting fracture has been questioned, as fractures often originate from margins of restoration. This study determined fracture resistance of highly translucent monolithic zirconia crowns with different margin designs in terms of marginal thickness and collar height. Materials and Methods. Zirconia blanks (Ceramill® Zolid HT+) were selected for the fabrication of zirconia crowns according to different designs, including varying margin thicknesses (light chamfer, CL; heavy chamfer, CH) and collar heights (no collar, NC; low collar, LC; high collar, HC), which resulted in CLNC, CLLC, CLHC, CHNC, CHLC, and CHHC groups (15 crowns each). The crowns were seated on a metal die and loaded vertically through round end punch (θ = 10 mm), contacting with inclined planes of cusp in a testing machine with crosshead speed of 0.2 mm/min until fracture. Videos with a rate of 50 frames/second were used to record fracture. Fracture load (N) and durable period (s) were compared for significant differences using ANOVA and Bonferroni test (α = 0.05). Results. The mean ± sd of fracture load (N) and durable time (s) were 3211 ± 778 and 212 ± 47 for CLNC; 3041 ± 1370 and 188 ± 53 for CLLC; 2913 ± 828 and 192 ± 27 for CLHC; 4226 ± 905 and 245 ± 35 for CHNC; 4486 ± 807 and 228 ± 29 for CHLC; and 4376 ± 1043 and 227 ± 37 for CHHC. This indicated that marginal thickness had a significant influence on load-bearing capacity and durable time (p<0.05). No significant impact of collar height was shown, either on load-bearing capacity or durable time (p>0.05). No interaction between two factors was presented (p>0.05). Conclusions. Heavy chamfer margin provided stronger zirconia crown than light chamfer, but both were capable of withstanding fracture load higher than maximum masticatory force. Neither presence nor absence of collar indicated any impact on strength. Fabrication of zirconia crowns with either heavy or light chamfer margin and either presence or absence of collar, with the consideration of emergence profile, should be considered.

2020 ◽  
Vol 14 (02) ◽  
pp. 245-249
Author(s):  
Haider Hasan Jasim ◽  
Meelad Basil Findakly ◽  
Nada Ali Mahdi ◽  
Mustafa Tariq Mutar

Abstract Objectives The aim of this study was to compare the effects of two margin designs (shoulderless and slight chamfer) with two occlusal thicknesses on fracture resistance and failure mode of the monolithic zirconia crowns. Materials and Methods Forty nickel–chromium dies were duplicated from the previous two prepared teeth using a three-dimensional optical scanner. Nickel–chromium supporting dies were divided into two main groups (n = 20) according to the type of margin design: group A, slight chamfer margin design and group B, shoulderless margin design. These groups were further divided into two subgroups according to the occlusal thicknesses (0.5 and 1 mm). The digital imaging of each die was done using a three-dimensional optical scanner, then zirconia blocks were milled by 5-axis machine. The crowns were cleaned by alcohol, air dried, and cemented by resin cement. Next, the crowns were subjected to 500 hot and cold cycles (30 seconds for each cycle). The samples were subjected to a static load until failure using an electronic universal testing machine and fracture resistance was recorded in Newton (N). Statistical Analysis Data were analyzed using the test of normality (Shapiro–Wilk test) and two-way analysis of variance (ANOVA) test. Results  The highest mean fracture load was recorded by the shoulderless (1 mm occlusal thickness) subgroup (3,992.5 N), followed by shoulderless (0.5 mm occlusal thickness) subgroup (3,244.4 N), and the slight chamfer (1 mm occlusal thickness) subgroup (2,811 N). The lowest mean of fracture load was recorded by slight chamfer (0.5 mm occlusal thickness) subgroup (1,632.9 N). The two-way ANOVA test revealed a significant difference between the four subgroups. Regarding the fracture mode, the slight chamfer subgroups showed a severe fracture of the restoration while the shoulderless subgroups showed a fracture through the midline of the restoration. Conclusion Within the limitation of the comparative study, shoulderless margin design has a more favorable outcome than a slight chamfer design in all thicknesses. Although the restoration with reduced occlusal thickness has lower fracture resistance than 1 mm occlusal thickness, the 0.5 mm restorations still can tolerate occlusal forces.


2016 ◽  
Vol 41 (5) ◽  
pp. E118-E130 ◽  
Author(s):  
ETP Bergamo ◽  
WJ da Silva ◽  
PF Cesar ◽  
AA Del Bel Cury

SUMMARY Monolithic zirconia crowns have many favorable properties and may potentially be used to solve dental problems such as chipping. However, monolithic zirconia crown resistance can be affected by its phase transformation when subjected to low temperatures, humidity, and stress. This study evaluated the fracture load and phase transformation of monolithic zirconia crowns submitted to different thermal and mechanical aging tests. Seventy monolithic zirconia crowns were randomly divided into the following five groups: control, no treatment; hydrothermal aging at 122°C, two bar for one hour; thermal fatigue, 104 cycles between 5°C and 55°C, dwell time, 30 seconds; and mechanical fatigue, 106 cycles with a load of 70 N, sliding of 1.5 mm at 1.4 Hz; and combination of mechanical plus thermal fatigue. Fracture load was measured with a universal testing machine. Surface changes and fracture mode and origin were examined with a scanning electron microscope. Monoclinic phase content was evaluated by x-ray diffraction. The fracture load was analyzed using one-way analysis of variance at a level of 5%, and Weibull distribution was performed. No statistically significant differences were observed in the mean fracture load and characteristic fracture load among the groups (p&gt;0.05). The Weibull modulus ranged from 6.2 to 16.6. The failure mode was similar for all groups with the crack origin located at the contact point of the indenter. Phase transformation was shown at different surfaces of the crown in all groups (1.9% to 8.9%). In conclusion, monolithic zirconia crowns possess high fracture load, structural reliability, and low phase transformation.


2018 ◽  
Vol 28 (1) ◽  
pp. 64-70 ◽  
Author(s):  
Fahad Bakitian ◽  
Przemek Seweryniak ◽  
Evaggelia Papia ◽  
Christel Larsson ◽  
Per Vult von Steyern

Author(s):  
Marwah Ismael Abdulazeez ◽  
Manhal A. Majeed

Abstract Objective The aim of this study was to evaluate the influence of different marginal designs (deep chamfer, vertical, and modified vertical with reverse shoulder) on the fracture strength and failure modes of monolithic zirconia crowns. Materials and Methods Thirty sound human maxillary first premolar teeth with comparable size were used in this study. The teeth were divided randomly into three groups according to the preparation design (n = 10): (1) group A: teeth prepared with a deep chamfer finish line; (2) group B: teeth prepared with vertical preparation; and (3) group C: teeth prepared with modified vertical preparation, where a reverse shoulder of 1 mm was placed on the buccal surface at the junction of middle and occlusal thirds. All samples were scanned by using an intraoral scanner (CEREC Omnicam, Sirona, Germany), and then the crowns were designed by using Sirona InLab 20.0 software and milled with a 5-axis machine. Each crown was then cemented on its respective tooth with self-adhesive resin cement by using a custom-made cementation device. A single load to failure test was used to assess the fracture load of each crown by using a computerized universal testing machine that automatically recorded the fracture load of each sample in Newton (N). Statistical Analysis The data were analyzed statistically by using one-way analysis of variance test and Bonferroni test at a level of significance of 0.05. Results The highest mean of fracture load was recorded by chamfer (2,969.8 N), which followed by modified vertical (2,899.3 N) and the lowest mean of fracture load was recorded by vertical (2,717.9 N). One-way ANOVA test revealed a significant difference among the three groups. Bonferroni test showed a significant difference between group A and group B, while a nonsignificant difference was revealed between group C with group A and group B. Conclusion Within the limitations of this in vitro study, the mean values of fracture strength of monolithic zirconia crowns of all groups were higher than the maximum occlusal forces in the premolar region. The modification of the vertical preparation with a reverse shoulder placed at the buccal surface improved the fracture strength up to the point that it was statistically nonsignificant with the chamfer group.


2011 ◽  
Vol 27 (10) ◽  
pp. 1045-1053 ◽  
Author(s):  
Bogna Stawarczyk ◽  
Mutlu Özcan ◽  
Malgorzata Roos ◽  
Albert Trottmann ◽  
Irena Sailer ◽  
...  

2020 ◽  
Vol 62 (1) ◽  
pp. 55-60
Author(s):  
Per Heyser ◽  
Vadim Sartisson ◽  
Gerson Meschut ◽  
Marcel Droß ◽  
Klaus Dröder

2017 ◽  
Vol 68 (1) ◽  
pp. 94-100
Author(s):  
Oana Tanculescu ◽  
Adrian Doloca ◽  
Raluca Maria Vieriu ◽  
Florentina Mocanu ◽  
Gabriela Ifteni ◽  
...  

The load-bearing capacity and fracture pattern of direct inlay-retained FRC FDPs with two different cross-sectional designs of the ponticwere tested. The aim of the study was to evaluate a new fibre disposition. Two types of composites, Filtek Bulk Fill Posterior Restorative and Filtek Z250 (3M/ESPE, St. Paul, MN, USA), and one braided polyethylene fibre, Construct (Kerr, USA) were used. The results of the study suggested that the new tested disposition of the fibres prevented in some extend the delamination of the composite on buccal and facial sides of the pontic and increased the load-bearing capacity of the bridges.


Sign in / Sign up

Export Citation Format

Share Document