scholarly journals Seismic Response Analysis and Connection Performance Evaluation of a Hybrid Coupled PEC Wall System

2020 ◽  
Vol 2020 ◽  
pp. 1-16
Author(s):  
Yun Shi ◽  
Mingzhou Su ◽  
Lu Jiang ◽  
Qiaoling Zhou ◽  
Lingyu Guan ◽  
...  

This paper proposes a hybrid coupled partially encased composite (PEC) wall system, obtained through the connection of two PEC walls by means of the shear critical steel coupling beams with an innovative welded connection. This structural solution is designed to take advantage of both the stiffness of the PEC walls (required to limit building damage under frequent earthquakes) and the ductility of the steel coupling beams (necessary to dissipate energy under medium-intensity and high-intensity earthquakes). The connection performance of an innovative rigid joint with different configurations in this system is studied through pseudostatic analysis, and the seismic performance of the proposed hybrid coupled PEC wall system is evaluated through multirecord nonlinear dynamic analysis of a set of case studies. Adopted finite element models are developed and validated against the available experimental results. A summary of the results is presented and discussed to highlight the potential of the proposed hybrid coupled PEC wall systems. The key feature of this system is development of a reasonable two-level yielding mechanism (the first level is the yielding of the coupling beams, and the second level is the yielding of the PEC wall) without damage to the welded joints.

2012 ◽  
Vol 160 ◽  
pp. 87-91
Author(s):  
Wei Jun Yang ◽  
Ming Sheng Duan ◽  
Ming Juan Yin

In order to grasp the seismic performance of the concrete perforated brick masonry building, nonlinear dynamic analysis is used for seismic response analysis of multi-storey building. In the degradation of trainer restoring force model,it is proposed that the yield moment of the inflection point is calculated by linear interpolation, the unloading time of inflection point is calculated by the precise non-iterative, which approach to improve the accuracy and efficiency of nonlinear analysis. Example shows: concrete perforated brick masonry structure in the 7-degree multi-zone can be widely used.


2012 ◽  
Vol 204-208 ◽  
pp. 1229-1232
Author(s):  
Sun Woong Kim ◽  
Wan Shin Park ◽  
Nam Young Eom ◽  
Hyun Do Yun

Hybrid coupled shear wall system with steel coupling beams has known as the effective lateral load resisting system for tall buildings subjected to earthquake. This paper addresses the influence on horizontal ties of steel coupling beams in pseudo strain hardening cementitious composite (PSH2C) hybrid coupled shear wall. Test variables included the connection detail and types of material, concrete and PSH2C, in the connection region. The results show that Specimen PSH2C-SB and PSH2C-SBVRT exhibits a better stable behavior than Specimens HCWS-SB and HCWS-SBVRT.


1999 ◽  
Vol 5 (9) ◽  
pp. 71-76
Author(s):  
Takao MATSUMURA ◽  
Shinichiro ASANO ◽  
Jun YAMADA ◽  
Masao KOBA ◽  
Koji ITO ◽  
...  

2014 ◽  
Vol 711 ◽  
pp. 520-524 ◽  
Author(s):  
Huan Qin Liu ◽  
Wei Bin Li ◽  
Ruo Yang Wu ◽  
Lin Fei Yan

Based on one 240-meter-high special-shaped RC chimney, the structure’s dynamic performance and elastic-plastic seismic response analysis has been studied in detail. From the analysis, it demonstrates the weak areas in the chimney. The interlayer displacement angle about corresponding performance points under four kinds of loading mode were also acuired, and the response of four loading patterns were analyzed.


Sign in / Sign up

Export Citation Format

Share Document