scholarly journals Percutaneous Atrial Septal Defect Closure Using the Occlutech Figulla Device in Adults: More than 800 Patient-Years of Follow-Up

2020 ◽  
Vol 2020 ◽  
pp. 1-5
Author(s):  
R. J. R. Snijder ◽  
L. E. Renes ◽  
D. Bosshardt ◽  
M. J. Suttorp ◽  
J. M. ten Berg ◽  
...  

Purpose. The Occlutech Figulla occluder has been proven safe and effective at midterm follow-up after percutaneous atrial septal defect (ASD) closure. We describe the safety and efficacy at long-term follow-up in adults. Methods. All consecutive adult patients that underwent ASD closure between 2008 and 2015 were included. All complications were registered. Residual left-to-right shunt (LRS) was diagnosed using color-Doppler transthoracic echocardiography (TTE). Right-to-left shunting was diagnosed using contrast TTE. Successful closure was defined as no LRS at follow-up. Results. In total, 166 patients (mean age 56.7 ± 16.1 years; 62% female) underwent percutaneous ASD closure using the Occlutech Flex I (70%) or Flex II (30%) device (diameter 24 mm; range 10–40 mm) under general anaesthesia and transoesophageal echocardiographic guidance. Long-term follow-up data were available for 144 patients (87%) with a mean follow-up of 5.9 ± 2.6 years, a total of 814 patient-years. During hospitalization, device embolization occurred in three patients (1.8%) with successful extraction in all. During the long-term follow-up, 15 patients (9.8%) suffered new-onset atrial fibrillation and stroke occurred in 2.1%. There was no residual LRS at 12-month follow-up. No device embolization occurred during the long-term follow-up. Conclusion. Percutaneous ASD closure using the Occlutech device appears to be safe at long-term follow-up with a high successful closure rate at one year.

2019 ◽  
Vol 3 (2) ◽  
Author(s):  
Marco Bergonti ◽  
Olga Toscano ◽  
Giovanni Teruzzi ◽  
Daniela Trabattoni

Abstract Background Percutaneous atrial septal defect (ASD) closure carries a not negligible burden of complications, such as the erosion of cardiac structures surrounding the device. Complications related to erosion are rare and often occur during the first 6 months after implantation. Case summary A 40-year-old female patient underwent percutaneous ASD closure in 2006. After 12 years of uneventful follow-up, in March 2018, a device dislodgement causing atrial shunting was incidentally discovered and was attributed to device-induced atrial septal erosion. The patient successfully underwent surgical removal of the device and correction of the interatrial defect. Discussion Our purpose is to underline the importance of staged long-term imaging follow-up, even many years after a successful procedure and to highlight the possible risk factors leading to this worrisome condition. In addition, we sought to underline the possible risks associated with deficient aortic rim and explain pros and cons of different approaches.


Author(s):  
Meisam Mokhtari ◽  
Zahra Khajali ◽  
Mona Heidarali ◽  
Majid Haghjoo

Atrial fibrillation (AF) is the most commonly treated arrhythmia in clinical practice and is often found in association with an atrial septal defect (ASD). However, ASD closure rarely confers complete arrhythmia control. A 23-year-old man presented to our center with frequent episodes of palpitations. AF was documented in 12-lead electrocardiography, and echocardiography showed a secundum-type ASD, 14 mm in size, with a significant left-to-right shunt. ASD closure was performed successfully with an ASD occluder device with no residual shunting. During follow-up, the patient experienced several episodes of AF. Thirteen months after the ASD closure, cryoballoon pulmonary vein isolation was done successfully with no complications. During a 12-month follow-up, he had no symptoms or AF recurrences, and echocardiography showed no residual shunting. This study showed that cryoballoon pulmonary vein isolation could be performed successfully without residual shunts in patients with ASD closure devices.


2014 ◽  
Vol 42 (1) ◽  
pp. 43-49 ◽  
Author(s):  
Jun-Gang Nie ◽  
Jian-Zeng Dong ◽  
Mohamed Salim ◽  
Song-Nan Li ◽  
Xiao-Yan Wu ◽  
...  

2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
P.J Prochownik ◽  
T Przewlocki ◽  
B Sobien ◽  
U Gancarczyk ◽  
M Olszowska ◽  
...  

Abstract Objective Closure of the atrial septal defect in the elderly patients is controversial. The aim of the study was to evaluate the outcomes of transcatheter closure of secundum atrial septal defect (ASD) in elderly patients. Methods From a total of 650 pts with ASD who underwent transcatheter closure 120 pts over 60 years (70 F, 50 M) with a mean age of 66.7±18.1 (60–78) were analyzed. All patients had an isolated secundum ASD with a mean Qp:Qs: 2.79±1.8 (1.5–3.9). A symptom-limited treadmill exercise tests with respiratory gas exchange analysis and transthoracic color Doppler echocardiographic study as well as Quality of life (QoL) measured using the SF36 questionnaire (SF36q) were repeated in all pts before procedure and after 12 months of follow-up. Results The device was successfully implanted in all pts (procedure time 30.1±9.9 (10–59) minutes, fluoroscopy time 10.1±7.2 (6–40) minutes). There were no major complications. The defect echo diameter was 19.5±15.4 (12 - 34) mm. The mean balloon stretched diameter of ASD was 22.0±7.8 (14 - 36) mm. The diameter of the implanted devices ranged 16 - 38 mm. After 12 months of ASD closure, all the pts showed a significant improvement of exercise capacity parameters. Seven QoL parameters (except mental health) improved at 12 months follow up compared to their baseline data. The mean SF36q scale increased significantly in 96 (80.2%) pts of mean 41.6±26.1 (4–71). The right ventricular dimension decreased in 101 pts (84.2%) (Table 1). Conclusions Closure of ASD in elderly patients caused a significant clinical and hemodynamic improvement after percutaneous treatment, which is maintained to long-term follow-up what justified this procedure in old age. Funding Acknowledgement Type of funding source: None


2019 ◽  
Vol 40 (Supplement_1) ◽  
Author(s):  
M Komar ◽  
T Przewlocki ◽  
B Sobien ◽  
P Prochownik ◽  
U Gancarczyk ◽  
...  

Abstract Objective Closure of atrial septal defect in patients with borderline shunt is controversial. The aim of the study was to evaluate the outcomes of transcatheter closure of secundum atrial septal defect (ASD) in the patients with the borderline shunt. Methods 215 pts (126 F,89 M) with a mean age of 31.9±18.2 (16–58) years with a small ASD who underwent transcatheter closure were analyzed. All patients had an isolated secundum ASD with pulmonary to systemic blood flow Qp:Qs ratio≤1.5, mean 1.2±0.6 (1.1–1.5). A symptom-limited treadmill exercise test with respiratory gas exchange analysis, transthoracic color Doppler echocardiographic study and Quality of life (QoL) (using the SF36 questionnaire (SF36q)) were repeated in all pts before and 36 months after the procedure. Results The device was successfully implanted in all pts (procedure time 19.1±5.2 (8–38) minutes, fluoroscopy time 8.1±4.4 (6–13) minutes). There were no major complications. The defect echo diameter was 7.7±3.9 (5 - 15) mm. The diameter of the implanted devices ranged from 6 to 18 mm. After 36 months of ASD closure, all the pts showed a significant improvement of exercise capacity. 7 QoL parameters (except mental health) improved at 36 months of follow-up compared with baseline. The mean SF36q scale increased in 168 (78.1%) pts of mean 40.2±20.1 (9–72). The right ventricular dimension decreased in 173 pts (80.4%) (Table 1). Table 1 Parameter Before ASD closure 36 months after ASD closure p value Time of exercise (min) 12.1±5.2 18.6±4.3 <0.001 VO2 peak (ml/kg/min) 10.2±4.7 14.8±4.2 <0.001 SF36q scale 0–100 37.3±22.3 79±29.5 <0.001 Right atrial area (cm2) 20.1±1.7 14.7±1.5 <0.001 Right ventricular area (cm2) 18.1±1.4 12.2±1.5 <0.001 Conclusions ASD closure in patients with borderline shunt resulted in a significant and long-term clinical and hemodynamic improvement after percutaneous treatment.


1996 ◽  
Vol 4 (3) ◽  
pp. 164-167
Author(s):  
Binali Mavitaş ◽  
S Fehmi Katircioğlu ◽  
Birol Yamak ◽  
Ahmet Saritaş ◽  
Gürkan Uzunonat ◽  
...  

Between 1968 and 1995, a total of 153 patients who were between 35 and 63 years of age (mean 49.8 years), underwent surgery for secundum type atrial septal defect. There were 78 (50.9%) males and 75 females (49.1 %). Mean left-to-right shunt ratio was calculated as 2.49. Mean pulmonary artery pressure was 50.15 mm Hg. Three patients died within 30 days of surgery, giving a hospital mortality of 1.96%. Long-term follow-up was available in 135 cases (90%). Total follow-up was 967.3 patient-years and ranged from 3 months to 11.3 years (mean 7.16 years). There were no late deaths reported. Four patients were readmitted with atrial fibrillation and 2 with pericardial effusion. In our experience, surgical closure of atrial septal defect in adults was found to be successful, safe, and with low morbidity in patients with pulmonary hypertension and congestive heart failure.