scholarly journals Performance of Special-Shaped Concrete-Filled Square Steel Tube Column under Axial Compression

2020 ◽  
Vol 2020 ◽  
pp. 1-16 ◽  
Author(s):  
Zhen Wang ◽  
Xuejun Zhou ◽  
Fangshuai Wei ◽  
Mingyang Li

The axial compressive performance of novel L-shaped and T-shaped concrete-filled square steel tube (L/T-CFSST) column was assessed in this study. Ten L/T-CFSST columns were tested to failure under axial load. The experimental data were used to determine various failure modes, bearing capacities, and load-displacement curves. The test parameters included the section form, steel tube thickness, steel yield strength, and slenderness ratio. The axial compressive performance of the L/T-CFSST column proved favorable, and each square steel tube showed strong cooperative performance. The failure mode of the stub column specimen (H/D ≤ 3) was strength failure caused by local buckling of the steel tube and that of the medium-long column member (H/D > 3) was instability failure caused by overall bending of the specimen. A finite element analysis (FEA) model was established and successfully validated by comparison against the test results. Based on the FEA model, parametric analyses were conducted to investigate the effects of steel tube thickness, concrete strength, steel yield strength, and slenderness ratio. The ultimate loads obtained from the experiments and FEA were compared to the results calculated by the available design codes. A formula was established to calculate the axial compressive strength and stability bearing capacity of the L/T-CFSST column accordingly. The calculation results are in close agreement with the FEA and experimental results, and the proposed formula may provide a workable reference for practicing engineers.

2021 ◽  
Vol 2101 (1) ◽  
pp. 012059
Author(s):  
Z J Yang ◽  
X Li ◽  
G C Li ◽  
S C Peng

Abstract Hollow concrete-filled steel tubular (CFST) member is mainly adopted in power transmission and transformation structures, but when it is used in the superstructure with complex stress, the hollow CFST member has a low bearing capacity and is prone to brittle failure. To improve the mechanical performance of hollow CFST members, a new type of reinforced hollow high strength concrete-filled square steel tube (RHCFSST) was proposed, and its axial compression performance was researched. 18 finite element analysis (FEA) models of axially loaded RHCFSST stub columns were established through FEA software ABAQUS. The whole stress process of composite columns was studied, and parametric studies were carried out to analyze the mechanical performance of the member. Parameters of the steel strength, steel ratio, deformed bar and sandwich concrete strength were varied. Based on the simulation results, the stress process of members can be divided into four stages: elastic stage, elastoplastic stage, descending stage and gentle stage. With the increase of steel strength, steel ratio, the strength of sandwich concrete and the addition of deformed bars, the ultimate bearing capacity of members also increases. Additionally, the increment of those parameters will improve the ductility of the member, except for the sandwich concrete strength.


2011 ◽  
Vol 94-96 ◽  
pp. 220-224 ◽  
Author(s):  
Xi Guang Cui ◽  
Hai Dong Xu

Considering the strain rate then puts forward the modified uniaxial dynamic constitutive model related to strain rate in concrete-filled square steel tube and the modified calculation results match well with the experimental results. Based on the above conclusion, uniaxial compression performance finite element analysis with different strain rate among 10-5/s–10-3/s is completed, the results showed that strain rate can obviously change the dynamic performance of the concrete-filled square steel tube. Through the analysis of the influencing factors of the core concrete compressive strength, it is showed that with the increasing of the strain rate and the improving of concrete strength, the ultimate bearing capacity of concrete-filled square steel tube is higher and the ductility is reduced. With the increasing of stirrup ratio, ultimate bearing capacity is greater and the ductility is enhanced. With the sectional dimensions increasing, the ultimate bearing capacity is greater and the ductility is enhanced.


Author(s):  
Xindong Ding ◽  
Shuqing Wang ◽  
Yu Liu ◽  
Zepeng Zheng

Axial compression tests were carried out on 6 square steel tube confined concrete short columns and 6 BFRP square pipe confined concrete axial compression tests. The concrete strength grades were C30, C40, and C50. The test results show that the failure modes of steel pipe and BFRP pipe are obviously different, and the BFRP pipe undergoes brittle failure. Compared with the short columns of concrete confined by BFRP pipes, the ultimate bearing capacity of axial compression is increased by -76.46%, -76.01%, and -73.06%, and the ultimate displacements are -79.20%, -80.78%, -71.71%.


Author(s):  
Chao Hou ◽  
Shameer Saleh ◽  
Lin-Hai Han ◽  
You-Xing Hua

Concrete filled steel tubular (CFST) truss structures have been adopted in various infrastructures worldwide for past several decades. Application of CFST truss is more prevalent especially in areas where harsh marine condition with chloride corrosion limits the design life of structures. Design of joints is one of the most complicated issues in CFST truss structures; and it becomes more critical when corrosion causes section loss in the outer steel tube. Improved designs in terms of economy and durability need to be suggested based on rational research on composite K-joints in corrosive environment, whilst such research is very limited up until now. This paper thus attempts to study the behaviour of circular concrete filled steel tubular (CFST) K-joints under combined effect of long-term loading and corrosion. A finite element analysis (FEA) model is presented and verified against existing test results. The model is then utilized to perform mechanism analysis of CFST K-joints under varying loading and corrosion situations. Failure modes, detailed propagation of yield and stress distribution between the core concrete in chord and the tubular steel is investigated, based on which a favourable mode of failure is suggested in terms of maximum joint capacity. Finally, a full range analysis of the load-deformation characteristics is carried out for various corrosion situations, with the corresponding joint strength as well as ductility predicted.


2011 ◽  
Vol 287-290 ◽  
pp. 1037-1042 ◽  
Author(s):  
Jun Guang Zhang ◽  
Yong Jian Liu ◽  
Jian Yang ◽  
Kai Lei Xu

For further study of mechanical properties of concrete-filled steel box columns (CFSBCs) with longitudinal stiffeners, axially loading tests of CFSBCs with longitudinal stiffeners was conducted to obtain their ultimate bearing capacity and failure modes. The test results were compared with those of hollow steel box columns with longitudinal stiffeners. Cross section of the test specimen was scaled from a chord member of Dongjiang Bridge. The experimental results show that failure mode of CFSBCs with longitudinal stiffeners is local buckling of steel plates, which is different from that of concrete-filled thin wall steel tube columns with longitudinal stiffeners. Although longitudinal stiffeners can prevent global buckling of steel plates, the effect is less obvious than that of concrete-filled thin wall steel tube columns. Meanwhile, three-dimensional finite element models (FEM) of the specimens were modeled using computer program ANSYS to obtain bearing capacities and load-strain curves. The FEM results coincide quite well with the test results. Further, influence of width to thickness ratio on mechanical behavior of CFSBCs was analyzed using FEM.


2010 ◽  
Vol 156-157 ◽  
pp. 1555-1558
Author(s):  
Min Ding ◽  
Zhen Hua Hou ◽  
Xiu Gen Jiang ◽  
Zi Chen Lin ◽  
Guang Kui Zhang ◽  
...  

The study on tension behavior of casing and dowel joint of square steel tube was carried out by using finite element analysis software ANSYS/LS-DYNA with consideration of geometric nonlinearity, material nonlinearity and contact nonlinearity. On this basis, the effects of inside tube wall thickness, main tube wall thickness, and inserting depth on failure mode, ultimate tensile load and deformation of casing and dowel joint of square steel tube was discussed. The results show that there are three types of failure modes, i.e., bolt failure, inside tube failure and main tube failure, when the joints are subjected to axial tension force. Compare to the joint with the same wall thickness of inside tube and main tube, the reduction of wall thickness of inside tube or main tube will weaken greatly the ultimate tensile load of the joint. The ultimate tensile load of casing and dowel joints is proportional to bolt shear strength, tube wall thickness, inserting depth, and tube edge length. The fruits are useful to the design and application of casing and dowel joints of square steel tube.


Author(s):  
Xindong DING ◽  
Shuqing Wang ◽  
Yu Liu ◽  
Zepeng Zheng

Axial compression tests were carried out on 6 square steel tube confined concrete short columns and 6 BFRP square pipe confined concrete axial compression tests. The concrete strength grades were C30, C40, and C50. The test results show that the failure modes of steel pipe and BFRP pipe are obviously different, and the BFRP pipe undergoes brittle failure. Compared with the short columns of concrete confined by BFRP pipes, the ultimate bearing capacity of axial compression is increased by -76.46%, -76.01%, and -73.06%, and the ultimate displacements are -79.20%, -80.78%, -71.71%.


Author(s):  
Hao Dinh Phan

This paper presents a numerical analysis of the seismic behavior of square concrete filled steel tubular (CFST) columns. Finite element analysis (FEA) models in ABAQUS software were used to simulate a series of columns subjected to axial compression and cyclic lateral loading. The CFST columns were simulated using nonlinear tri-dimensional (3-D) finite elements for the infilled concrete, and nonlinear two-dimensional (2-D) finite elements for the steel tube. The feasibility of the FEA model has been validated by published experimental results. The validated FEA model was further extended to conduct parametric studies with various parameters including axial load level (n), width-to-thickness ratio of steel tube (B/t), and concrete strength. The numerical analysis results reveal that with the same B/t and constitute materials, the higher the axial compression, the lower the shear strength and deformation capacity were. The thicker steel wall (B/t = 21) resulted in higher strength and larger deformation capacity of the column. Increasing concrete strength helped to significantly develop the column’s shear strength in all cases. Meanwhile, it just led to an increase in deformation capacity in some cases depending on n and B/t. This study also reveals that the square CFST columns with B/t of 21 satisfy the seismic performance demand in high seismic zones (ultimate interstory drift ratio (IDRu) not less than 3% radian) under the two axial load levels, 0.35 and 0.45, but the columns with B/t of 28 satisfy the above demand under just one axial load level of 0.35. Keywords: square concrete filled steel tubular (CFST) columns; finite element analysis (FEA) model; width-to-thickness ratio (B/t); high axial load level; seismic behavior.


2018 ◽  
Vol 763 ◽  
pp. 533-540
Author(s):  
Yuji Koetaka ◽  
Koichi Taniguchi ◽  
Iathong Chan

In steel building structures, local buckling and/or fracture of columns could occur during strong ground motions, furthermore complete collapse might be induced due to the column strength degradation. In this paper, cold press-formed square tube columns are targeted, and numerical model being able to trace precisely degradation behavior is proposed. In order to take account of both local buckling and fracture with low computational costs, multi-spring model which consists of some uni-axial springs is adopted. Axial force-deformation relationships of uni-axial springs are provided on flat area and corner area of square tube severally, and are separated into skeleton part and hysteresis part. All parameters on force-deformation relationship are identified based on finite element analysis results of short columns under monotonic or cyclic axial loading. Comparing between analysis results by multi-spring models and past cyclic loading test results or finite element analysis results, it is clarified that degradation behavior of cold press-formed square steel tube columns can be traced with high accuracy.


Author(s):  
Jin-Yang Chen ◽  
Lin-Hai Han ◽  
Fa-Cheng Wang ◽  
Ting-Min Mu

Concrete-encased CFST (concrete-filled steel tube) members have been widely used in high-rise buildings and bridge structures. In this paper, the axial performance of a typical concrete-encased CFST box member with inner CFST and outer reinforced concrete (RC) is investigated. A finite element analysis (FEA) model is established to analyze the compressive behavior of the composite member. The material nonlinearity and the interaction between concrete and steel tube are considered. A good agreement is achieved between the measured and predicted results in terms of the failure mode and the load-deformation relation. The verified FEA model is then used to conduct the full range analysis on the load versus deformation relations. The loading distributions of different components inclouding concrete, steel tube and longitudinal bar during four stages are discussed. Typical failure modes, internal force distribution, stress development and the contact stress between concrete and steel tube are also presented. The parametric study on the compressive behavior is conducted to investigate the effects of various parameters, e.g. the strength of concrete and steel, longitudinal bar ratio and stirrup space on the sectional capacity and the ductility of the concrete-encased CSFT box member.  


Sign in / Sign up

Export Citation Format

Share Document