scholarly journals Comparative Study on Steady and Unsteady Flow in a Centrifugal Compressor Stage

2019 ◽  
Vol 2019 ◽  
pp. 1-12
Author(s):  
Changhee Kim ◽  
Changmin Son

Steady Reynolds-averaged Navier-Stokes (RANS) simulation with the mixing-plane approach is the most common procedure to obtain the performance of a centrifugal compressor in an industrial development process. However, the accurate prediction of complicated flow fields in centrifugal compressors is the most significant challenge. Some phenomena such as the impeller-diffuser flow interaction generates the unsteadiness which can affect the steady assumption. The goal of this study is to investigate the differences between the RANS and URANS simulation results in a centrifugal compressor stage. Simulations are performed at three operating points: near surge (NS), design point (DP), and near choke (NC). The results show that the RANS simulation can predict the overall performance with reasonable accuracy. However, the differences between the RANS and URANS simulation are quite significant especially in the region that the flows are highly unsteady or nearly separated. The RANS simulation is still not very accurate to predict the time-dependent quantities of the flow structure. It shows that the URANS calculations are necessary to predict the detailed flow structures and performance. The phenomena and mechanisms of the complex and highly unsteady flow in the centrifugal compressor with a vaned diffuser are presented and analyzed in detail.

2013 ◽  
Vol 136 (3) ◽  
Author(s):  
Daniel R. Grates ◽  
Peter Jeschke ◽  
Reinhard Niehuis

The subject of this paper is the investigation of unsteady flow inside a transonic centrifugal compressor stage with a pipe-diffuser by utilizing unsteady 3D Reynolds-averaged Navier–Stokes simulations (unsteady 3D URANS). The computational fluid dynamics (CFD) results obtained are compared with detailed experimental data gathered using various steady and unsteady measurement techniques. The basic phenomena and mechanisms of the complex and highly unsteady flow inside the compressor with a pipe-diffuser are presented and analyzed in detail.


Author(s):  
Y. Bousquet ◽  
X. Carbonneau ◽  
I. Trebinjac

The most common procedure to obtain the performance of a centrifugal compressor in an industrial development process is based on the use of a steady RANS model with the mixing-plane approach. However some phenomena such as the flow interaction between the impeller and the diffuser can be the source of unsteady effects which can affect the steady model prediction. This paper investigates the ability of a steady simulation to predict the overall performance and the flow structures in a subsonic centrifugal compressor stage by comparison with time-dependent results. Simulations are performed considering three operating points: peak efficiency, close to the stability limit and close to the blockage. The results show that the steady model is accurate enough to predict the stage static-to-total pressure ratio. However, in location where high level of fluctuation is expected, the steady model shows some weakness to predict the time-averaged quantities of the flow structure.


Author(s):  
A. Koumoutsos ◽  
A. Tourlidakis ◽  
R. L. Elder

This paper describes the unsteady flow analysis in a centrifugal compressor stage using a three dimensional CFD algorithm. The flow unsteadiness arising from the interaction between the impeller and the diffuser has been analysed using an algorithm suitable for equal or multiple number of rotor and diffuser blades. The multi-block, structured grid CFD code TASCflow was used as a basis and algorithm development was undertaken to provide the required capability of modelling the unsteady interactions of the impeller and the diffuser. The centrifugal compressor stage studied consists of an impeller with splitters and a vaned diffuser. The results presented are for off-design flow conditions where some experimental results were available for comparison. The results obtained for the steady-state model show a good agreement with the measurements. In general the unsteady flow field obtained show a reasonable agreement with experimental data and demonstrates significant differences when compared to the steady state results especially in terms of the velocity field. A detailed analysis of the unsteady flow field is carried out using Fourier transforms of velocity and pressure at various locations of the flow field and the level of unsteadiness is determined as distributed to various frequencies. The unsteadiness in the impeller passage is much less than in the diffuser where a strong coupling is predicted in the vaneless space.


Author(s):  
Daniel R. Grates ◽  
Peter Jeschke ◽  
Reinhard Niehuis

The subject of this paper is the investigation of unsteady flow inside a transonic centrifugal compressor stage with pipe-diffuser by utilizing unsteady 3D Navier-Stokes simulations (unsteady 3D URANS). The CFD results obtained are compared with detailed experimental data gathered using various steady and unsteady measurement techniques. The basic phenomena and mechanisms of the complex and highly unsteady flow inside the compressor with pipe-diffuser are presented and analyzed in detail.


2017 ◽  
Vol 140 (1) ◽  
Author(s):  
Lee Galloway ◽  
Stephen Spence ◽  
Sung In Kim ◽  
Daniel Rusch ◽  
Klemens Vogel ◽  
...  

The stable operating range of a centrifugal compressor stage of an engine turbocharger is limited at low mass flow rates by aerodynamic instabilities which can lead to the onset of rotating stall or surge. There have been many techniques employed to increase the stable operating range of centrifugal compressor stages. The literature demonstrates that there are various possibilities for adding special treatments to the nominal diffuser vane geometry, or including injection or bleed flows to modify the diffuser flow field in order to influence diffuser stability. One such treatment is the porous throat diffuser (PTD). Although the benefits of this technique have been proven in the existing literature, a comprehensive understanding of how this technique operates is not yet available. This paper uses experimental measurements from a high pressure ratio (PR) compressor stage to acquire a sound understanding of the flow features within the vaned diffuser which affect the stability of the overall compression system and investigate the stabilizing mechanism of the porous throat diffuser. The nonuniform circumferential pressure imposed by the asymmetric volute is experimentally and numerically examined to understand if this provides a preferential location for stall inception in the diffuser. The following hypothesis is confirmed: linking of the diffuser throats via the side cavity equalizes the diffuser throat pressure, thus creating a more homogeneous circumferential pressure distribution, which delays stall inception to lower flow rates. The results of the porous throat diffuser configuration are compared to a standard vaned diffuser compressor stage in terms of overall compressor performance parameters, circumferential pressure nonuniformity at various locations through the compressor stage and diffuser subcomponent analysis. The diffuser inlet region was found to be the element most influenced by the porous throat diffuser, and the stability limit is mainly governed by this element.


Author(s):  
T. Ch. Siva Reddy ◽  
G. V. Ramana Murty ◽  
Prasad Mukkavilli ◽  
D. N. Reddy

Numerical simulation of impeller and low solidity vaned diffuser (LSD) of a centrifugal compressor stage is performed individually using CFX- BladeGen and BladeGenPlus codes. The tip mach number for the chosen study was 0.35. The same configuration was used for experimental investigation for a comparative study. The LSD vane is formed using standard NACA profile with marginal modification at trailing edge. The performance parameters obtained form numerical studies at the exit of impeller and the diffuser have been compared with the corresponding experimental data. These parameters are pressure ratio, polytropic efficiency and flow angle at the impeller exit where as the parameters those have been compared at the exit of diffuser are the static pressure recovery coefficient and the exit flow angle. In addition, the numerical prediction of the blade loading in terms of blade surface pressure distribution on LSD vane has been compared with the corresponding experimental results. Static pressure recovery coefficient and flow angle at diffuser exit is seen to match closely at higher flows. The difference at lower flows could be due to the effect of interaction between impeller and diffuser combinations, as the numerical analysis was done separately for impeller and diffuser and the effect of impeller diffuser interaction was not considered.


Author(s):  
Isabelle Tre´binjac ◽  
Nicolas Bulot ◽  
Xavier Ottavy ◽  
Nicolas Buffaz

Numerical and experimental investigations were conducted in a transonic centrifugal compressor stage composed of a backswept splittered unshrouded impeller and a vaned diffuser. Unsteady 3D simulations were performed with the code elsA that solves the turbulent averaged Navier-Stokes equations, at three operating points: choked flow, peak efficiency and near surge. Unsteady pressure measurements up to 150 kHz were carried out in the entry zone of the vaned diffuser (in the vaneless space and in the semi-vaneless space) when the compressor came into surge. These static pressure sensors were mounted on the shroud enwall. The paper focuses on the vaneless and semi-vaneless space where the surge originates. A detailed analysis of the flow pattern coming from the unsteady computations from choked flow towards surge led to identify the physical mechanisms involved in the surge inception. It is shown that, when approaching surge, the flow is destabilized by a severe modification of the shock system in the vaned diffuser inlet. The first perturbation is acquired from the transducer located just upstream of the shock foot (i.e. on the vane suction side surface), indicating a movement of the shock towards the vaneless space. This perturbation travels upstream and leads to the strongest short-wavelength perturbation acquired from the transducer located just upstream of the vane leading edge. This strongest short-wavelength perturbation which level may reach almost four times the mean exit pressure value triggers the full scale instability.


Author(s):  
Chaolei Zhang ◽  
Qinghua Deng ◽  
Zhenping Feng

This paper describes the aerodynamic redesign and optimization of a typical single stage centrifugal compressor, in which the total pressure ratio was improved from the original 4.0 to final 5.0 with the restrictions of keeping the impeller tip diameter, the design rotational speed and the design mass flow rate unchanged. Firstly the backsweep angle and the outlet blade height of the impeller were adjusted and the vaned diffuser was redesigned. Then a sensitivity analysis of the aerodynamic performance correlated to the primary redesign centrifugal compressor stage with respect to the chosen redesign variables was conducted, according to the parameterized results of the impeller and the vaned diffuser. Secondly the impeller and the vaned diffuser were optimized respectively under the stage environment at the design operation condition to improve the stage isentropic efficiency by using a global optimization method which coupled Evolutionary Algorithm (EA) and Artificial Neural Network (ANN), provided by the commercial software NUMECA DESIGN-3D. Subsequently the detailed performance maps of the centrifugal compressor stage corresponding to the primary redesign configuration and the optimum configuration were presented by Computational Fluid Dynamics (CFD) simulation. Finally the flow fields correlated to the centrifugal compressor configurations before and after optimization at the design operation condition were also compared and analyzed in detail. As a result the design target was achieved after the primary redesign, as a 2.7% gain in stage efficiency and a 3.6% increase in stage pressure ratio were obtained when compared with the primary redesign configuration after optimization. Moreover, the aerodynamic performance of the optimum configuration at the off-design operation conditions was also improved.


Author(s):  
James M. Sorokes ◽  
Jason A. Kopko

The paper addresses the use of a rib style (partial height) vaned diffuser to improve the flowfield downstream of a high flow coefficient centrifugal impeller. Empirical and analytical (3-D CFD) results are presented for both the original vaneless diffuser and the replacement rib configuration. Comparisons are made between the CFD results and the data obtained through single stage rig (SSTR) testing. Comments are offered regarding the qualitative and quantitative agreement between the empirical and analytical results.


Sign in / Sign up

Export Citation Format

Share Document