scholarly journals Hepatic Artery Pseudoaneurysm in the Liver Transplant Recipient: A Case Series

2019 ◽  
Vol 2019 ◽  
pp. 1-6
Author(s):  
David P. St. Michel ◽  
Naeem Goussous ◽  
Nathalie L. Orr ◽  
Rolf N. Barth ◽  
Stephen H. Gray ◽  
...  

Introduction. Hepatic artery pseudoaneurysm is a rare and potentially fatal complication of liver transplantation with a reported incidence of 0.3–2.6% and associated mortality approaching 75%. Clinical presentation typically includes sudden hypotension, gastrointestinal bleed or abnormal liver function tests within two months of transplantation. We report a series of four cases of hepatic artery pseudoaneurysm in adult liver transplant recipients with the goal of identifying factors that may aid in early diagnosis, prior to the development of life threatening complications. Methods. A retrospective chart review at a high volume transplant center revealed 4 cases of hepatic artery pseudoaneurysm among 553 liver transplants (Incidence 0.72%) between March 2013 and March 2017. Results. Two of the four patients died immediately after intervention, one patient survived an additional 151 days prior to death from an unrelated condition and one patient survived at two years follow up. All cases utilized multiple imaging modalities that failed to identify the pseudoaneurysm prior to diagnosis with computed tomography angiography (CTA). Two cases had culture proven preoperative intrabdominal infections, while the remaining two cases manifested a perioperative course highly suspicious for infection (retransplant for hepatic necrosis after hepatic artery thrombosis and infected appearing vessel at reoperation, respectively). Three of the four cases either had a delayed biliary anastomosis or development of a bile leak, leading to contamination of the abdomen with bile. Additionally, three of the four cases demonstrated at least one episode of hypotension with acute anemia at least 5 days prior to diagnosis of the hepatic artery pseudoaneurysm. Conclusions. Recognition of several clinical features may increase the early identification of hepatic artery pseudoaneurysm in liver transplant recipients. These include culture proven intrabdominal infection or high clinical suspicion for infection, complicated surgical course resulting either in delayed performance of biliary anastomosis or a biliary leak, and an episode of hypotension with acute anemia. In combination, the presence of these characteristics can lead the clinician to investigate with appropriate imaging prior to the onset of life threatening complications requiring emergent intervention. This may lead to increased survival in patients with this life threatening complication.

2020 ◽  
Vol 3 (1) ◽  
Author(s):  
Alfredo Páez-Carpio ◽  
Elena Serrano ◽  
Federico Zarco ◽  
Constantino Fondevila ◽  
Marta Burrel

Abstract Background The formation of a hepatic artery pseudoaneurysm in a liver implant is a rare but potentially fatal complication. Fistulization of such pseudoaneurysms into the bile duct is sporadic. The most common causes of hepatic artery pseudoaneurysm are infection at the anastomosis site, inadequate surgical technique, and an iatrogenic origin due to minimally invasive procedures. Currently, there is no standardized treatment in neither of these complications, with surgery and various endovascular procedures among the alternatives available. None of these therapeutic approaches has demonstrated a significant increase in long-term liver implant preservation. Case presentation A 56-year-old man with a two-month liver transplant presented with massive upper gastrointestinal bleeding and hemobilia shortly after the performance of an endoscopic retrograde cholangiopancreatography due to the presence of a hepatic artery pseudoaneurysm with fistulization into the bile duct. This case report describes the successful treatment of both complications, the hepatic artery pseudoaneurysm and the arterio-biliary fistula, using a covered coronary stent placed in the hepatic artery. A year and a half after treatment, the patient maintains a preserved liver implant and a patent hepatic artery. Conclusions Treatment of a hepatic artery pseudoaneurysm with fistulization into bile duct using a covered coronary stent allowed the correct repair of the defect, adequate hemorrhage control, and long-term liver implant preservation.


Surgery ◽  
2017 ◽  
Vol 162 (5) ◽  
pp. 1101-1111 ◽  
Author(s):  
Masato Fujiki ◽  
Koji Hashimoto ◽  
Emmanouil Palaios ◽  
Cristiano Quintini ◽  
Federico N. Aucejo ◽  
...  

2005 ◽  
Vol 46 (5) ◽  
pp. 455-461 ◽  
Author(s):  
P. Boraschi ◽  
F. Donati ◽  
M. C. Cossu ◽  
R. Gigoni ◽  
C. Vignali ◽  
...  

Purpose: To evaluate the ability of multi-detector row computed tomography angiography (CTA) in detecting hepatic artery complications in the follow-up of liver transplant patients, performing volume-rendering as reconstruction technique. Material and Methods: The anatomy of hepatic artery was studied in 27 liver transplant recipients with a four-row CT scanner using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 6–8 mm/s; spiral reconstruction time, 0.5 s; reconstruction interval, 0.5 mm; mAs, 160; kVp, 120. Before the study, the patients received 1000 ml of water as oral contrast agent to produce negative contrast in the stomach and the small bowel. A non-ionic contrast medium was infused intravenously at a rate of 5 ml/s with a bolus tracking system. Volume-rendering of hepatic artery was performed with the 3D Virtuoso software. Results: The celiac trunk, the hepatic artery, and the right and left hepatic arteries were successfully displayed in high detail in all patients. Side branches, including small collaterals, and hepatic artery anastomosis could also be readily visualized. Volume-rendered CTA detected six hepatic artery stenoses, two hepatic artery thromboses, and two intrahepatic pseudoaneurysms. In two cases, CT detected hepatic artery stenosis with a diameter reduction of less than 50%, while digital subtraction angiography showed a normal artery. Conclusion: Volume-rendered multi-detector CTA is a promising non-invasive technique, since it allows images of high quality to be generated with excellent anatomical visualization of the hepatic artery and its complications in liver transplant recipients.


HPB ◽  
2016 ◽  
Vol 18 (3) ◽  
pp. 279-286 ◽  
Author(s):  
Jonathan G. Stine ◽  
Shawn J. Pelletier ◽  
Timothy M. Schmitt ◽  
Robert J. Porte ◽  
Patrick G. Northup

Sign in / Sign up

Export Citation Format

Share Document