scholarly journals Right-Sided Subcutaneous Implantable Cardioverter Defibrillator System Implantation in a Patient with Complex Congenital Heart Disease and Dextrocardia: A Case Report and Literature Review

2019 ◽  
Vol 2019 ◽  
pp. 1-6
Author(s):  
Bandar Al-Ghamdi

Patients with complex congenital heart disease (CHD) and low left ventricular ejection fraction are at an increased risk of sudden cardiac death (SCD). Prevention of SCD by subcutaneous implantable cardioverter defibrillator (S-ICD) implantation may represent a valuable option in certain CHD patients. Patients with CHD and dextrocardia pose a challenge in S-ICD system implantation, and nonstandard device placement may be required. Furthermore, electrocardiogram (ECG) screening prior to S-ICD implantation in CHD patients has significant limitations. This case represents the placement of a S-ICD system on the right side of the chest in a 26-year-old male with severe biventricular failure and nonsustained ventricular tachycardia following multiple corrective surgeries of situs inversus totalis, double-outlet right ventricle with a ventricular septal defect, and pulmonary atresia. The use of S-ICDs in a CHD population and in particular CHD patients with dextrocardia and right-sided S-ICD implantation is briefly discussed.

2019 ◽  
Author(s):  
Linda Wang ◽  
Neeraj Javadekar ◽  
Ananya Rajagopalan ◽  
Nichole M. Rogovoy ◽  
Kazi T. Haq ◽  
...  

AbstractBackgroundThe goals of this study were: assess left-and right-sided subcutaneous implantable cardioverter-defibrillator (S-ICD) eligibility in adult congenital heart disease (ACHD) patients, use machine learning to predict S-ICD eligibility in ACHD patients, and transform 12-lead ECG to S-ICD 3-lead ECG, and vice versa.MethodsACHD outpatients (n=101; age 42±14 y; 52% female; 85% white; left ventricular ejection fraction (LVEF) 56±9%) were enrolled in a prospective study. Supine and standing 12-lead ECG was recorded simultaneously with a right- and left-sided S-ICD 3-lead ECG. Peak-to-peak QRS and T amplitudes, RR, PR, QT, QTc, QRS intervals, Tmax, and R/Tmax (31 predictor variables) were tested. Model selection, training, and testing were performed using supine ECG datasets. Validation was performed using standing ECG datasets and out-of-sample non-ACHD population (n=68; age 54±16 y; 54% female; 94% white; LVEF 61±8%).ResultsA 40% of participants were ineligible for S-ICD. Tetralogy of Fallot patients passed right-sided screening (57%) more often than left-sided (21%; McNemar’s χ2P=0.025). The ridge model demonstrated the best cross-validation function. Validation of the ridge models was satisfactory for standing left-sided [ROC AUC 0.687 (95%CI 0.582-0.791)] and right-sided [ROC AUC 0.655(95%CI 0.549-0.762)] S-ICD eligibility prediction. Out-of-sample validation in the non-ACHD population yielded a 100% sensitivity of the pre-selected threshold for the elastic net model. Validation of the transformation matrices showed satisfactory agreement (<0.1 mV difference).ConclusionNearly half of the contemporary ACHD population is ineligible for S-ICD. Machine-learning prediction of S-ICD eligibility can be used for screening of S-ICD candidates.


EP Europace ◽  
2019 ◽  
Vol 21 (10) ◽  
pp. 1537-1542 ◽  
Author(s):  
Kevin Willy ◽  
Florian Reinke ◽  
Nils Bögeholz ◽  
Julia Köbe ◽  
Lars Eckardt ◽  
...  

Abstract Aims The subcutaneous implantable cardioverter-defibrillator (S-ICDTM) is an important advance in device therapy for the prevention of sudden cardiac death (SCD). Although current guidelines recommend S-ICDTM use, long-term data are still limited, especially in subgroups such as adult patients with congenital heart diseases. This cohort is of high interest because of the difficult anatomic conditions in these patients. Methods and results All S-ICDTM patients with an underlying congenital heart disease (CHD) resulting in an indication for ICD implantation (n = 20 patients) in our large-scaled single-centre S-ICDTM registry (n = 249 patients) were included in this study. Baseline characteristics, appropriate and inappropriate shocks, and complications were documented in a mean follow-up of 36 months. Primary prevention of SCD was the indication for implantation of an S-ICDTM in six patients (30%). Of all 20 patients with an overall mean age of 40.5 ± 11.5 years, 12 were male (60%). The mean left ventricular ejection fraction was 46.5 ± 11.3%. Nine episodes of ventricular tachycardia (two monomorphic and seven polymorphic) were adequately terminated in three patients (15%). In two patients, T-Wave-Oversensing resulting in an inappropriate shock was observed, which could be managed by changing the sensing vector or activation of the SMART PASSTM filter. There were no S-ICDTM system-related infections. In one patient, surgical revision was necessary due to a persistent haematoma. Conclusion The S-ICDTM seems to be a valuable option for the prevention of SCD in patients with various CHDs and complex anatomical anomalies. The S-ICDTM is safe and works effectively, also in these complex patients. Inadequate shock delivery was rare and could be managed by reprogramming.


2021 ◽  
Vol 10 (4) ◽  
Author(s):  
Andrea Demarchi ◽  
Stefano Cornara ◽  
Antonio Sanzo ◽  
Simone Savastano ◽  
Barbara Petracci ◽  
...  

Background When implantable cardioverter defibrillator (ICD) battery is depleted most patients undergo generator replacement (GR) even in the absence of persistent ICD indication. The aim of this study was to assess the incidence of ventricular arrhythmias and the overall prognosis of patients with and without persistent ICD indication undergoing GR. Predictors of 1‐year mortality were also analyzed. Methods and Results Patients with structural heart disease implanted with primary prevention ICD undergoing GR were included. Patients were stratified based on the presence/absence of persistent ICD indication (left ventricular ejection fraction ≤35% at the time of GR and/or history of appropriate ICD therapies during the first generator's life). The study included 371 patients (82% male, 40% with ischemic heart disease). One third of patients (n=121) no longer met ICD indication at the time of GR. During a median follow‐up of 34 months after GR patients without persistent ICD indication showed a significantly lower incidence of appropriate ICD shocks (1.9% versus 16.2%, P <0.001) and ICD therapies. 1‐year mortality was also significantly lower in patients without persistent ICD indication (1% versus 8.3%, P =0.009). At multivariable analysis permanent atrial fibrillation, chronic advanced renal impairment, age >80, and persistent ICD indication were found to be significant predictors of 1‐year mortality. Conclusions Patients without persistent ICD indication at the time of GR show a low incidence of appropriate ICD therapies after GR. Persistent ICD indication, atrial fibrillation, advanced chronic renal disease, and age >80 are significant predictors of 1‐year mortality. Our findings enlighten the need of performing a comprehensive clinical reevaluation of ICD patients at the time of GR.


2002 ◽  
Vol 103 (s2002) ◽  
pp. 233S-236S ◽  
Author(s):  
Andrea SZÜCS ◽  
Katalin KELTAI ◽  
Endre ZIMA ◽  
Hajnalka VÁGÓ ◽  
Pál SOÓS ◽  
...  

The incidence of ventricular tachyarrhythmias in the early post-operative period following implantable cardioverter-defibrillator (ICD) implantation is relatively high compared with that in control periods. Since endothelin-1 (ET-1) has been proven to be an endogenous arrhythmogenic substance, we investigated the changes in serum ET-1 and big-ET levels in patients undergoing ICD implantation. Serum concentrations of ET-1 and big-ET were measured in 14 patients with various heart diseases before the operation, as well as 1min and 1h after the last shock therapy. Big-ET levels and the sum of ET-1 and big-ET levels were unchanged immediately after the operation, but had increased significantly by 1h after implantation (before, 1.57±0.61pmol/l; 1min, 1.86±0.87pmol/l; 1h, 4.29±1.65pmol/l for big-ET; before, 3.44±1.07pmol/l; 1min, 3.79±1.29pmol/l; 1h, 6.36±2.03pmol/l for big-ET+ET-1). There was a significant correlation between left ventricular ejection fraction and big-ET level measured 1h after the last shock delivery (r =-0.542, P<0.05). We conclude that the increased big-ET level observed 1h after the last induction and shock therapy of ventricular fibrillation might have a pathophysiological role in the increased incidence of post-operative spontaneous ventricular arrhythmias.


2020 ◽  
Vol 41 (Supplement_2) ◽  
Author(s):  
J Freeman ◽  
J Bjerre ◽  
C Parzynski ◽  
K Minges ◽  
T Ahmad ◽  
...  

Abstract Background/Introduction Uncertainty remains regarding the benefit of primary prevention ICDs overall in contemporary practice, and particularly in those with NICM compared with ICM. Purpose To evaluate the contemporary risk of death and readmission following following implantable cardioverter-defibrillator (ICD) implantation in patients with non-ischemic cardiomyopathies (NICM) compared with ischemic cardiomyopathies (ICM) in a large nationally representative cohort in the United States. Methods We used data from the American College of Cardiology (ACC) National Cardiovascular Data Registry (NCDR) ICD Registry linked with Medicare claims from April 1, 2010 to December 31, 2013 to establish a cohort of NICM and ICM patients with a left ventricular ejection fraction ≤35% who received a de novo, primary prevention ICD. We compared mortality, all-cause readmission, and heart failure readmission using Kaplan-Meier curves and Cox proportional hazard regressions models. We also evaluated temporal trends in mortality. Results Among 31,044 NICM and 68,458 ICM patients with a median follow up of 2.4 years, one-year mortality was significantly higher in ICM patients (12.3%) compared with NICM (7.9%, p&lt;0.001). The higher mortality in ICM patients remained significant after adjustment for covariates (hazard ratio (HR) 1.40; 95% confidence interval (CI) 1.36 to 1.45), and was consistent in subgroup analyses. These findings were consistent across the duration of the study. ICM patients were also significantly more likely to be readmitted for all causes (adjusted HR 1.15, CI 1.12 to 1.18) and for heart failure (adjusted HR 1.25, CI 1.21 to 1.31). Conclusions The risks of mortality and hospital readmission after primary prevention ICD implantation were significantly higher in patients with ICM compared with NICM, and these findings were consistent across all patient subgroups tested and over the duration of the study. Funding Acknowledgement Type of funding source: None


2011 ◽  
Vol 7 (3) ◽  
pp. 199
Author(s):  
Alessandro Marinelli ◽  
Mario Luzi ◽  
Alessandro Capucci ◽  
◽  
◽  
...  

Implantable cardioverter-defibrillator (ICD) therapy is a mainstay in sudden cardiac death (SCD) prevention. Its efficacy has been proven in several conditions such as heart failure and reduced left ventricular ejection fraction (LVEF) and in familial SCD syndromes. In contrast to the fairly clear role of ICD therapy for secondary prevention, its role and indications for primary prevention of SCD has been more difficult to define. Many questions remain unresolved in this setting, such as the choice of the optimal time for implantation after a myocardial infarction and the degree of LVEF reduction that is able to predict future events and to justify the risks of ICD implant. The choice of ICD therapy may also be challenging in patients with different demographic features and comorbidities from that enrolled in clinical trials. Finally, the relative rarity of familial SCD syndromes seriously limits the data upon which recommendations are based and therefore many questions concerning the risk-benefit of ICD implantation remain unresolved.


Sign in / Sign up

Export Citation Format

Share Document