scholarly journals Prefabricated Bar System for Immediate Loading in Edentulous Patients: A 5-Year Follow-Up Prospective Longitudinal Study

2018 ◽  
Vol 2018 ◽  
pp. 1-7 ◽  
Author(s):  
Enrico F. Gherlone ◽  
Gianpaolo Sannino ◽  
Andrea Rapanelli ◽  
Roberto Crespi ◽  
Giorgio Gastaldi ◽  
...  

Objectives. The aim of this clinical study was to evaluate a new type of prefabricated bar system, supported by axial and tilted implants at 5-year follow-up. Materials and Methods. Twenty-nine consecutive participants (19 females, 10 males) (mean age 61.4 years), edentulous in one or both jaws, with severe atrophy of the posterior regions, were treated according to the All-on-four® protocol with immediately loaded axial (64) and tilted (64) implants supporting complete-arch screw-retained prostheses (12 maxillary, 20 mandibular) featuring a prefabricated bar as framework. Follow-up visits were performed at 3, 6, 12, 24, 48, and 60 months after implant insertion. Radiographic assessments were made using panoramic radiographs obtained immediately after surgery and at each follow-up visit. Bone level measurements around the axial and tilted implants were compared by means of the Student’s t-test. Results. One axial implant failed in the lower jaw and did not compromise prosthetic function. The 60-month overall implant survival rate was 100% for axially positioned implants and 98.44% for tilted implants. The implant survival rates were 100% in the maxilla and 98.75% in the mandible. None of the 32 fixed prostheses were lost during the observation period, representing a prosthetic survival rate of 100%. No statistically significant differences (P>0.05) in marginal bone loss between tilted and axial implants were detected in either jaw over time. Conclusions. The use of the evaluated prefabricated bar for immediately loaded implants placed according to the All-on-four concept may significantly reduce implant failures; however, more long-term prospective clinical trials are needed to affirm the effectiveness of the surgical-prosthetic protocol.

2021 ◽  
Vol 10 (5) ◽  
pp. 940
Author(s):  
Jakub Hadzik ◽  
Paweł Kubasiewicz-Ross ◽  
Izabela Nawrot-Hadzik ◽  
Tomasz Gedrange ◽  
Artur Pitułaj ◽  
...  

Short 6 mm dental implants are considered as an alternative to the maxillary sinus elevation and bone augmentation procedure where there is a reduced alveolar ridge height. The aim of this study was to compare the implant survival rate between short dental implants (6 mm) and regular length implants (11–13 mm) when placed in combination with bone grafting and loaded with a single non splinted crown, seven years after placing the implant. It was conducted as a controlled clinical study of 30 patients with partial edentulism in the posterior maxilla. The protocol included radiological and clinical evaluation of the C/I ratio (length of the superstructure divided by the length of the implant crestal part), marginal bone level (MBL), ultrasonography measurement of soft tissue surrounding implant (STT), patient-reported outcomes, and biological and technical complications. A total number of 28 implants (93%) remained integrated during follow-up period. MBL of 0.50 and 0.52 mm was observed for short implants and regular implants, respectively. MBL was checked for correlation with STT, and a negative correlation was found between MBL: STT. Our study has demonstrated a significantly lower implant survival rate for short implants compared to regular implants (87% compared to 100%). Despite the loss of several implants, good clinical results were achieved in the remaining implants in both groups. It is, therefore, worth considering short implants as an alternative to regular implants with a sinus lift surgery.


2020 ◽  
Vol 9 (12) ◽  
pp. 3943
Author(s):  
João Caramês ◽  
Ana Catarina Pinto ◽  
Gonçalo Caramês ◽  
Helena Francisco ◽  
Joana Fialho ◽  
...  

This retrospective study evaluated the survival rate of short, sandblasted acid-etched surfaced implants with 6 and 8 mm lengths with at least 120 days of follow-up. Data concerning patient, implant and surgery characteristics were retrieved from clinical records. Sandblasted and acid-etched (SLA)-surfaced tissue-level 6 mm (TL6) or 8 mm (TL8) implants or bone-level tapered 8 mm (BLT8) implants were used. Absolute and relative frequency distributions were calculated for qualitative variables and mean values and standard deviations for quantitative variables. A Cox regression model was performed to verify whether type, length and/or width influence the implant survival. The cumulative implant survival rate was assessed by time-to-event analyses (Kaplan–Meier estimator). In all, 513 patients with a mean age of 58.00 ± 12.44 years received 1008 dental implants with a mean follow-up of 21.57 ± 10.77 months. Most implants (78.17%) presented a 4.1 mm diameter, and the most frequent indication was a partially edentulous arch (44.15%). The most frequent locations were the posterior mandible (53.97%) and the posterior maxilla (31.55%). No significant differences were found in survival rates between groups of type, length and width of implant with the cumulative rate being 97.7% ± 0.5%. Within the limitations of this study, the evaluated short implants are a predictable option with high survival rates during the follow-up without statistical differences between the appraised types, lengths and widths.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Eduardo Anitua ◽  
Adriana Montalvillo ◽  
Asier Eguia ◽  
Mohammad Hamdan Alkhraisat

Abstract Purpose There is paucity in the studies that assess dental implants replacing failed dental implants due to peri-implantitis. This study aims to evaluate the clinical outcomes of these implants in terms of implant survival and marginal bone loss. Methods Patients in this retrospective study were selected if having one or more implants removed due to peri-implantitis and the placement and loading of dental implants in the same region from April 2010 to December 2019. Information was collected about the patient's demographic data, implant dimensions, surgical and prosthetic variables. Changes in peri-implant bone level, cumulative implant survival rate and technical complications were assessed. Results Three hundred and eighty one dental implants in 146 patients that were placed in the same position or one-tooth position mesially/distally to the site of explantation were included. The patients' mean age was 63 ± 10 years. Ninety seven patients were females and 49 were males. After a mean follow-up of 34 ± 17 months, two implants failed. The cumulative survival rate was 99%. The marginal bone loss was −0.1 ± 0.6. Immediate or delay replacement of the failed implant did not affect implant survival or marginal bone stability. All the prostheses were screw-retained and presented the following complications: ceramic chipping (3 events), resin tooth fracture (1 event) and prosthetic screw loosening (1 event). Conclusions Dental implants replacing failed implants due to peri-implantitis would be an option in the management of peri-implantitis. They showed high survival rate and marginal bone stability.


2019 ◽  
Vol 8 (12) ◽  
pp. 2142 ◽  
Author(s):  
Massimo Del Fabbro ◽  
Tiziano Testori ◽  
Vladan Kekovic ◽  
Funda Goker ◽  
Margherita Tumedei ◽  
...  

Background: The aim of this systematic review was to evaluate the survival rates of immediately loaded implants after at least five years. Besides implant failure, the amount of marginal bone loss around implants and the complication type were assessed. Methods: The electronic search was undertaken on Medline, Scopus, and Cochrane Central Register of Controlled Trials using key terms such as: “immediate loading”, “immediate function”, “immediate restoration”, “immediate temporization”, “dental implants”, “fully edentulous patients”, “partially edentulous patients”. The search terms were combined using the Boolean operators AND, OR. The last electronic search was performed on 15 February 2018. Two authors independently screened the studies, extracted the data, and assessed the risk-of bias. The main outcomes recorded for each study were: implant and prosthesis success and survival, marginal bone level change, incidence and type of complications. Kaplan–Meier analysis was used to estimate cumulative survival rates. Results: Thirty-four prospective studies with at least five-year follow-up, published between 2007 and 2017 were included. A total of 5349 immediately loaded implants in 1738 patients were analyzed. The mean follow-up was 72.4 months (median 60 months, 95% confidence intervals (CI): 64.53, 80.25 months, range 60 to 147 months). The mean weighted implant survival was 97.4% (median 98.15%, 95% CI: 96.29%, 98.54%, range 83.80% to 100%). Cumulative survival rate of implants placed in the mandible was significantly higher than for the maxilla (p < 0.01). No significant difference in failure rate was found among the types of prosthesis employed (p = 0.27). The mean peri-implant bone level change at the end of the follow-up in each study ranged from 0.3 to 1.7 mm. Conclusion: Immediate loading of implants appears to have long-term predictability and success rate under well-defined circumstances.


2020 ◽  
Vol 46 (4) ◽  
pp. 407-413 ◽  
Author(s):  
Leon Pariente ◽  
Karim Dada ◽  
Marwan Daas ◽  
Susy Linder ◽  
Michel Dard

The aim of this case series was to assess, over a period of 24 months, the clinical and radiographic outcomes in partially edentulous patients receiving bone-level tapered implants. In total, 33 partially edentulous patients and 50 implants were evaluated. Patients received single or multiple implants in the posterior maxilla. Clinical and radiographic measurements of vertical bone levels were assessed at surgery, at loading, and 6, 12, and 24 months after surgery. The success and survival rates of the implants were also evaluated. Within the 24-month follow-up, only 1 implant failed (2.0%). Other biological or technical complications were not observed. The mean insertion torque was 34 ± 5.3 Ncm. Bone-level changes of 0.35 ± 0.23 mm were found between surgery and 12 months after surgery, and changes of 0.03 ± 0.05 mm were found between 12 months and 24 months after surgery. The overall change from surgery to 24 months after implant placement was 0.38 ± 0.24 mm. Most of the bone loss occurred between surgery and 3 months (0.28 ± 0.19 mm; P &lt; .001); thereafter, the loss was minimal and statistically nonsignificant. Bone-level tapered implants yielded a high survival and success rate with minimal bone-level changes. Tapered implants could be considered as a predictable treatment option for partially edentulous patients with different types of bone qualities and loading protocols.


2021 ◽  
Vol 10 (5) ◽  
pp. 1077
Author(s):  
Björn Gjelvold ◽  
Jenö Kisch ◽  
Bruno R. Chrcanovic

The aim of this prospective randomized clinical study was to compare the clinical treatment outcome for single dental implants submitted to either immediate loading (IL) or delayed loading (DL) after 5 years of follow-up. Fifty patients with a missing maxillary tooth (15–25) were randomly allocated to either the IL or DL. The treatment procedures included implant installation in healed sites, temporary screw-retained crown and replacement with a permanent single implant crown. The two groups were evaluated with regard to implant survival, marginal bone level, papillae index, pink and white esthetic score (PES, WES). At the 5-year follow-up the implant survival rate was 100% and 95.8% for IL and DL, respectively. Implant success rate was 91.7% and 83.3% for IL and DL, respectively. The mean ± SD marginal bone loss for IL and DL was −0.50 ± 0.73 mm and −0.54 ± 0.65 mm, respectively. (p = 0.782). Statistically significant less marginal bone loss was found non-smokers (p = 0.021). No statistically significant differences were found for IL and DL concerning papillae index PES and WES after 5 years. This study suggests that implant-supported single crowns in the maxillary aesthetic zone can present similar results with respect to either IL or DL after 5 years.


2014 ◽  
Vol 15 (4) ◽  
pp. 417-422 ◽  
Author(s):  
Ali M El-Sheikh ◽  
Omar F Shihabuddin

ABSTRACT Background The use of endosseous dental implants has led to more sophisticated fixed options when considering treatment of patients with distal extensions. The use of narrow-diameter implants may reduce the necessity for bone augmentation. The mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose The purpose of this study was to evaluate clinically and radiographically the performance of narrow-diameter bone level implants made from titanium-zirconium alloy (TiZr, RoxolidTM) in restoring unilateral atrophic mandibular distal extensions with fixed dental prostheses. Materials and methods Twenty partially edentulous patients with unilateral atrophic mandibular distal extensions received two 3.3 mm diameter bone level TiZr implants (Straumann AG, Basel, Switzerland). The two implants were restored with 3-units ceramo-metal fixed partial dentures. Standardized clinical and radiographic parameters (survival rate, probing pocket depth and marginal bone loss) were evaluated at the time of the completion of the prosthetic treatment (baseline) and after 3, 6 and 12 months of functional loading. Prosthetic complications were also assessed. Results The survival rate for narrow-diameter bone level TiZr implants was 100% after 1 year of functional loading. There were no statistically significant differences between the values of probing pocket depth over the follow-up period. All implants showed less than 1 mm of marginal bone loss at the end of the follow-up period. Conclusion Within the limitations of this 1-year pilot study, the use of narrow-diameter bone level TiZr implants appears to be predictable in restoring the unilateral atrophic mandibular distal extensions. This type of implants meets established success and survival criteria after 1 year. How to cite this article El-Sheikh AM, Shihabuddin OF. Clinical and Radiographic Evaluation of Narrow-Diameter Titanium-Zirconium Implants in Unilateral Atrophic Mandibular Distal Extensions: A 1-Year Pilot Study. J Contemp Dent Pract 2014;15(4):417-422.


2021 ◽  
Vol 2021 ◽  
pp. 1-11
Author(s):  
S. Storelli ◽  
A. Caputo ◽  
G. Palandrani ◽  
M. Peditto ◽  
M. Del Fabbro ◽  
...  

Objective. The objective of the present review is to assess the implant survival, marginal bone loss, and biomechanical features of narrow-diameter implants (2.5-3.5 mm) supporting or retaining full-arch fixed or removable restorations. Materials and Methods. Three operators screened the literature (PubMed, Cochrane Library, and Google Scholar) and performed a hand search on the main journals that focus on implantology until 24 March 2019. Only articles that considered full-arch restorations supported or retained by narrow-diameter implants (2.5-3.5 mm) were considered if they have a minimum of 10 patients and a mean follow-up of at least 6 months. The outcome variables were survival of implants and marginal bone loss. The review was performed according to the PRISMA statements. Risk of bias assessment was evaluated. Failure rates were analyzed using random effect Poisson regression models to obtain the summary estimate of 5-year survival rate and marginal bone loss. Results. A total of nine papers were finally selected, reporting a high survival rate of the implants. Eight studies focused only on the mandible while one study reported data from both mandible and maxilla. All studies reported on removable restorations; none focused on fixed rehabilitations. The estimated survival rate for 5 years of follow-up was calculated to be 92.25% for the implants. The estimated marginal bone loss after 5 years was calculated to be 1.40 mm. No study reported implant fractures. Conclusions. With the limitations of the present study, there is evidence that 2.5-3.5 mm narrow-diameter implants retaining a removable restoration can be a successful treatment in fully edentulous patients. No data on fixed restorations was available.


Author(s):  
Marco Tallarico ◽  
Aurea Maria Immacolata Lumbau ◽  
Silvio Mario Meloni ◽  
Irene Ieria ◽  
Chang-Joo Park ◽  
...  

Abstract Objective The purpose of the present prospective, case-series study was to report implant survival rate and marginal bone remodeling expected 5 years after loading using dental implants placed in daily practice. Materials and Methods This research was designed as an open-cohort, prospective, case-series evaluation. Any partially or completely edentulous patient, scheduled to receive at least one bone level implant, was considered eligible for this study. Primary outcome measurements were: implant and prosthetic cumulative survival rate and any complications experienced up to the 5-year follow-up. Secondary outcome measures were: thickness of gingival biotype, implant insertion torque, implant stability quotient, and marginal bone loss (MBL). Results Ninety consecutive patients (34 males and 56 females, aged between 24 and 81 years old [mean: 53.2 ± 15.4]) with 243 inserted implants were followed for at least 5 years after loading (mean: 65.4 ± 3.1 months; range from 60 to 72). At the 1-year follow-up, no drop-outs were recorded, but 17 patients (18.9%) with 18 restorations (12.6%) delivered on 34 implants (14%) were lost at the 5-year examination. At the 5-year follow-up examination, six implants lost osseointegration (97.5%). In the same period, four prostheses failed (97.2%). Five complications were reported in five different patients (prosthetic success rate was 96.5%, at patient level). Five years after loading, the mean MBL was 0.41 ± 0.30 mm. The difference from the 1-year data was 0.04 ± 0.19 mm. A statistically significant higher MBL was found for smokers, and patients with thin gingival biotype. The mean implant insertion torque was 42.9 ± 4.8 Ncm (range from 15 to 45 Ncm). Two-hundred and three implants (83.5%) were inserted with an insertion torque ≥35 and ≤45 Ncm. Conclusions High implant survival and success rate could be expected with stable marginal bone remodeling up to 5 years after loading. Smoking and thin tissue biotype were the most important variabilities associated with higher MBL. Further research studies are needed to confirm these results.


2019 ◽  
Vol 45 (6) ◽  
pp. 503-508 ◽  
Author(s):  
Meng Ma ◽  
Mengxing Qi ◽  
Dongsheng Zhang ◽  
Hongchen Liu

The purpose of this study is to analyze 1- and 3-year clinical performances of narrow diameter implants (NDIs) versus regular diameter implants (RDIs). A search of electronic databases and a manual search was performed for the time period January 2000 to April 2018. A meta-regression was used to evaluate the effects of the “fixed effects” model on the implant survival rates, prosthesis success rates and marginal bone loss (MBL) with follow-up time of 1 year and 3 years. Of the 11 studies included, the overall combined 1-year implant survival rates were 98.14% for NDIs and 98.20% for RDIs. The overall combined 3-year implant survival rates were 98.71% for NDIs and 98.84% for RDIs. The corresponding values for 1-year prosthesis success rates were 96.94% for NDIs and 99.25% for RDIs. The corresponding values for 3-year prosthesis success rates were 89.25% for NDIs and 96.55% for RDIs. The meta-regression showed no significant differences between NDIs and RDIs regarding implant survival rates, prosthesis success rates, and MBL in 1-year and 3-year follow-up (P &gt; .05). The results of this meta-analysis concluded that the implant diameter did not affect its survival rates, prosthesis success rates, and MBL in 1 and 3 years. The use of NDIs instead of bone augmentation procedures with RDIs did not affect its survival rates, prosthesis success rates, and MBL in the short-term and middle-term. However, more high-quality randomized controlled trials and long follow-up studies are needed on this topic.


Sign in / Sign up

Export Citation Format

Share Document