scholarly journals Experimental Investigation of Pressure Fluctuation, Vibration, and Noise in a Multistage Pump

2018 ◽  
Vol 2018 ◽  
pp. 1-13 ◽  
Author(s):  
Kai Wang ◽  
Zixu Zhang ◽  
Chen Xia ◽  
Zhongchun Liu

In order to measure the pressure pulsation, vibration, and noise characteristics of multistage centrifugal pump in different flow rates, a five-stage centrifugal pump was chosen as research object. The results show that the main frequency of pressure pulsation was BPF1, 9APF, BPF2, BPF2, and 9APF. According to the order of monitoring points, the intensity of the pressure fluctuation increased and then decreased, with the strongest fluctuation at monitoring point P2. The peak value of pressure fluctuation in monitoring point P2 was obviously higher than the other monitoring points. The main characteristic frequency of vibration is 4APF, BPF2, 9APF, 2BPF2, 3BPF1, 4BPF1, and 4BPF2. The number of characteristic frequencies at the outlet flange was significantly more than the number of characteristic frequencies at the inlet flange. As the flow rate increased, the vibration of motor gradually increased and the vibration of pump increased at first and then decreased. It reached the minimum vibration level in the design flow rate. Motor contributed the largest amount of noise caused by the pump unit. The noise level of measure point which is close to motor is higher than that of other measure points. As the flow rate increased, the noise incrementally increased, and the difference in noise level between measure points decreased gradationally. When the flow rate was 120 m3/h, the maximum difference value of different noise monitoring points was only 1.7 dB.

Water ◽  
2019 ◽  
Vol 12 (1) ◽  
pp. 126
Author(s):  
Houlin Liu ◽  
Ruichao Xia ◽  
Kai Wang ◽  
Yucheng Jing ◽  
Xianghui He

Experimental measurements to analyze the pressure fluctuation performance of a centrifugal pump with a vaned-diffuser, which its specific speed is 190. Results indicate that the main cause of pressure fluctuation is the rotor-stator interference at the impeller outlet. The head of the pump with vaned-diffuser at the design flow rate is 15.03 m, and the efficiency of the pump with a vaned-diffuser at the design flow rate reaches 71.47%. Pressure fluctuation decreases gradually with increasing distance from the impeller outlet. Along with the increase of the flow rate, amplitude of pressure fluctuation decreases. The amplitude of pressure fluctuation at the measuring points near the diffusion section of the pump body is larger than other measuring points. The variation tendency of pressure fluctuation at P1–P10 is the same, while there are wide frequency bands with different frequencies. The dominant frequency of pressure fluctuation is the blade passing frequency. The rotor-stator interference between the impeller and the vaned-diffuser gives rise to the main signal source of pressure fluctuation.


2019 ◽  
Vol 11 (3) ◽  
pp. 168781401982590 ◽  
Author(s):  
Kai Wang ◽  
Yu-cheng Jing ◽  
Xiang-hui He ◽  
Hou-lin Liu

In order to enhance the efficiency of centrifugal pump, the structure of a centrifugal pump with vaned diffuser, whose specific speed is 190, was numerically improved by trimming back-blades of impeller and smoothing sharp corner in annular chamber. The energy performance, the internal flow field, the axial force, the radial force, and the pressure pulsation of the pump were analyzed. Results show that efficiency of the improving scheme 1 under the design flow rate is 77.47%, which can balance 69.82% of the axial force, while efficiency of the improving scheme 2 under the design flow rate is the maximum, which could still balance 62.74% of the axial force. The pressure pulsations of the improving scheme 2 at the typical monitoring points are less than that of the improving scheme 1 and the original scheme. The difference of the radial force peak between the improving scheme 1 and the improving scheme 2 is very small. The vector distributions of the radial force of the improving scheme 1 and the improving scheme 2 are more uniform than that of the original scheme. Considering the efficiency, pressure pulsation, and axial force, experiment measurements on the improving scheme 2 were carried out to verify the effectiveness of the improvement result. Results of energy performance experiment show that efficiency of the improving scheme 2 under the design flow rate is 76.48%, which is 5.26 percentage points higher than that of the original scheme.


2012 ◽  
Vol 152-154 ◽  
pp. 935-939 ◽  
Author(s):  
Qiang Fu ◽  
Shou Qi Yuan ◽  
Rong Sheng Zhu

In order to study the rules of pressure fluctuation and the radial force under different positions in a centrifugal pump with low specific speed, and to find the relationship between each other, the three-dimensional ,unsteady Reynolds-averaged Navier-stokes equations with shear stress transport turbulent models were solved. The pressure fluctuation was obtained. The results showed that the pressure fluctuations were visible. The pressure fluctuations in the volute were relatively low at the design flow rate condition. The blade passing frequency dominates the pressure fluctuations, high frequency contents were found on the outlet of impeller but no high frequency information occured in casing. The radial force on the impeller was unsteady especially at the small flow rate.


2017 ◽  
Vol 9 (2) ◽  
pp. 168781401769249 ◽  
Author(s):  
Kai Wang ◽  
Zixu Zhang ◽  
Linglin Jiang ◽  
Houlin Liu ◽  
Yu Li

In order to save energy by broadening its application range, the influence of impeller trim on the performance of a two-stage self-priming centrifugal pump was numerically studied. The hydraulic performance experiments and self-priming experiments were carried out. And the unsteady performance of pressure fluctuation and radial force in the pump was analyzed. The results show that with the increase in impeller trim quantity, the best efficiency point of the pump would move to the small flow rate condition. Under the design flow rate, when both the two stages of the impeller were trimmed by 6%, head of the pump was reduced by 13%, efficiency of the pump was as well decreased by 1.69 percentage points, and self-priming time was increased by 1.7%. Thus, impeller trim can be used to meet the operating requirements in the head range of 94–107 m. With the increase in impellers trim quantity, the pressure fluctuation in the positive channel of the radial guide vane and the volute was smaller, while the radial force on the wall of radial guide vane and volute was also smaller.


2014 ◽  
Vol 496-500 ◽  
pp. 877-880
Author(s):  
Feng Xia Shi ◽  
Jun Hu Yang ◽  
Xiao Hui Wang

Two models of hydraulic turbine based on pump in reversal were simulated. Pressure distribution of flow field in Variable conditions was analysed and external characteristic was forecasted for hydraulic turbine. It was shown: the head increased with flow increased, with increasing of flow rate, efficiency first increased and then decreased. Compared with the turbine with a guide vane, the head of two models was almost equal, but the disparity of efficiency was large, and the efficiency of hydraulic turbine with a guide vane above on the efficiency of hydraulic turbine without guide vane. Pressure pulsation was existent in runner inlet. From runner inlet to runner outlet, the pressure distributed evenly from high to low. Added with a guide vane, the pressure distribution was more evenly than before and the Amplitude of pressure fluctuation decreased.


2020 ◽  
Vol 143 (2) ◽  
Author(s):  
Baoling Cui ◽  
Yingbin Zhang ◽  
Yakun Huang

Abstract Unsteady pressure pulsation and fluid force induced by flow instabilities in the centrifugal pump is an important cause of vibration, which is detrimental to the safe operation of the pump. In this study, we numerically investigated the pressure pulsation and radial force in a low-specific-speed centrifugal pump by using the detached-eddy simulation method. We also performed a vibration displacement experiment on the shaft of the centrifugal pump. The vortex identification method was introduced to clarify the internal correlation between unsteady flow structures with pressure pulsations. The results showed that the pressure pulsations at the impeller outlet were closely associated with the periodic vortex shedding from the blade pressure surface. The rotor–stator interaction between a relatively big trailing vortex core and volute tongue generated larger pressure pulsation and radial force in the pump at a low flow rate. Under a large flow rate, the trailing vortex core was easily broken and dispersed, and this resulted in smaller pressure pulsation and radial force compared with that at a low flow rate. Under the design flow rate, the pressure pulsation intensity and the radial force in the impeller were smaller than that under the off-design flow rate. Compared with the spectra between the radial force on the impeller and radial displacement on the shaft, they both presented higher amplitude at the shaft frequency. The vibration of the pump shaft was closely related to the radial force on the impeller.


2016 ◽  
Vol 33 (2) ◽  
Author(s):  
WANSHI QU ◽  
lei tan ◽  
Shuliang CAO ◽  
YUCHUAN WANG ◽  
YUN XU

Purpose The paper aims to investigate the clocking effect on a centrifugal pump with inlet guide vanes (IGVs). Design/methodology/approach The paper uses a computation fluid dynamics (CFD) framework to solve the unsteady flows in a centrifugal pump with inlet guide vanes. The relative position between the stationary vanes and the stationary volute tongue is defined as the clocking position when IGVs inside the suction pipe rotate along the circumferential direction. Findings The results show that clocking positions have little effect on the pump head and efficiency, however their influences are obvious for the pressure fluctuation and flow field in the centrifugal pump. The maximum difference of pressure amplitude at dominant frequency reach up to 28% on the monitoring point V8 at different clocking positions under design flow rate. For the large flow rate, the clocking effect on flow field and pressure fluctuation in centrifugal pump is similar to that of design flow rate. However, the clocking effect is nearly negligible at partial flow rate, because there are reverse flows around the tongue tip and obvious vortexes forming and developing in the impeller. Those complex phenomena interacting in the centrifugal pump make the clocking effect less evident. Originality/value The numerical investigation reveals the clocking effect on a centrifugal pump with inlet guide vanes, which also valuable for the stable operation and optimal design of centrifugal pumps.


Symmetry ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 311
Author(s):  
Renfei Kuang ◽  
Xiaoping Chen ◽  
Zhiming Zhang ◽  
Zuchao Zhu ◽  
Yu Li

This paper presents a large eddy simulation of a centrifugal pump impeller during a transient condition. The flow rate is sinusoidal and oscillates between 0.25Qd (Qd indicates design load) and 0.75Qd when the rotating speed is maintained. Research shows that in one period, the inlet flow rate will twice reach 0.5Qd, and among the impeller of one moment is a stall state, but the other is a non-stall state. In the process of flow development, the evolution of low-frequency pressure fluctuation shows an obviously sinusoidal form, whose frequency is insensitive to the monitoring position and equals to that of the flow rate. However, inside the impeller, the phase and amplitude in the stall passages lag behind more and are stronger than that in the non-stall passages. Meanwhile, the strongest region of the high-frequency pressure fluctuation appears in the stall passages at the transient rising stage. The second dominant frequency in stall passages is 2.5 times to that in non-stall passages. In addition, similar to the pressure fluctuation, the evolution of the low-frequency head shows a sinusoidal form, whose phase is lagging behind that by one-third of a period in the inlet flow rate.


Author(s):  
Ning Zhang ◽  
Bo Gao ◽  
Chao Li ◽  
Dan Ni ◽  
Guoping Li

Effects of the staggered blades on unsteady pressure pulsations of a centrifugal pump with a specific speed ns=147 are investigated by the numerical simulation method. The obtained results are compared with the original blades. To clarify the resulting effects, eight monitoring points are used to extract pressure signals at three typical working conditions, and component at the blade passing frequency fBPF is emphasized. Results show that the pump efficiency and head will be reduced by the staggered blades, and at the nominal flow rate, the reduction is about 1.5% from comparison with the original blades. For all the eight points, the staggered blades contribute to the reduction of pressure amplitudes at fBPF when the pump works at three flow rates. The averaged reduction is 15.5% at the nominal flow rate. However, the negative effect on the second harmonic of fBPF will be caused by the staggered blades, and the corresponding pressure amplitude will increase at 2fBPF. It means that the pressure pulsation energy will be redistributed among the discrete components in pressure spectrum by the staggered blades. From the TKE distribution, it is found that the TKE values on the blade pressure side will be significantly affected by the staggered blades.


Author(s):  
Hucan Hou ◽  
Yongxue Zhang ◽  
Zhenlin Li ◽  
Xin Zhou ◽  
Zizhe Wang

In order to effectively improve hydraulic performance of centrifugal pump on off-conditions, the hydraulic design of inlet guide vane (IGV) was completed by adopting two dimensional theory in-house code based on one kind of IS series of centrifugal pump, which can achieve pre-whirl regulation of centrifugal pump. During design process the trailing edge of vane is assumed as equal velocity moment condition, and the distribution of vane setting angle along meridional streamline is also given as a quartic function firstly, the camber line is then drawn by point-by-point integration method and thickened at both sides along circumferential direction. With local vortex dynamics diagnosis theory, the optimal improvement of vane space shape can be finished by adjusting the design parameters of vane setting angle distribution coefficient ap. The full flow passage numerical simulations of centrifugal pump with IGV device are completed to analyze the influence of pre-whirl regulation on hydraulic performance of centrifugal pump under various pre-whirl angles. The results show that the pre-whirl regulation can improve the hydraulic performance of centrifugal pump on off-conditions. Under the positive pre-whirl regulation conditions, the best efficient point shift to small flow rate zone, and under the negative pre-whirl regulation conditions it moves to large flow rate zone. Compared with the pump without IGV device at the same flow rate condition of 0.8Q (Q the design flow rate), the hydraulic efficiency of centrifugal pump with IGV device improves obviously and reaches up to 1.43%. Meanwhile compared with that installed with the straight vanes designed based on the traditional theory, the inner flow field of centrifugal pump with the designed vanes improves and the overall hydraulic efficiency of centrifugal pump is somewhat increased.


Sign in / Sign up

Export Citation Format

Share Document