scholarly journals A Comparative Study of Smartphone Game with Spirometry for Pulmonary Function Assessment in Stroke Patients

2018 ◽  
Vol 2018 ◽  
pp. 1-6 ◽  
Author(s):  
Sunghee Joo ◽  
Kyeongjin Lee ◽  
Changho Song

Background. The monitoring and rehabilitation of pulmonary function can be immensely important for long-term performance of daily life activities in stroke patients. In recent times, smartphone game-based assessment (SGA) has been gaining in popularity as an alternative to laboratory assessments. Hence, the aims of this study were (1) to quantify the reliability and validity of SGA for pulmonary function and (2) to assess the validity of SGA in comparison to spirometry. Materials/Methods. Thirty-four stroke subjects (age = 49.24 ± 8.25 years) performed spirometry and the smartphone game on different days. Spirometric values were obtained using a spirometer (SP-1, Schiller, USA). A breathing game application (Breathing+ package, Breathing Labs, Slovenia) was used to obtain the values for the SGA of pulmonary function. The concurrent validity was determined by comparing data collected from the 2 systems, and the reliability was determined by comparing data collected from 3 sessions of using the breathing game on a smartphone. Results. All parameters demonstrated excellent agreement with intraclass correlation coefficients (ICC (2.1)) values for reliability and concurrent validity. Conclusion. We compared the relationship between the SGA and the spirometry as certified pulmonary function test. The SGA data were statistically significant and reliable for pulmonary function assessment in stroke patients. It will therefore be useful during rehabilitation to improve pulmonary function and clinical monitoring in stroke patients.

2005 ◽  
Vol 25 (2) ◽  
pp. 44-54 ◽  
Author(s):  
Jeng-Liang Hwang

The purpose of this study was to examine the reliability and validity of the School Function Assessment (SFA)-Chinese version. The data drawn from the standardization sample of the instrument (N = 320) were used in the analyses. Using internal consistency procedures, Cronbach's alpha for each scale ranged from .94 to .98. The test—retest study reported intraclass correlation coefficients from .87 to .98 among the scales. Content validity of the SFA—Chinese version was confirmed by the overall high content validity indices (85% to 100%) determined by educational experts. Construct-related validity based on an exploratory factor analysis revealed two correlated functional domains of the SFA—Chinese version, “cognitive/behavioral” and “physical,” which were consistent with the theoretical construct hypothesized in the instrument. The known groups method demonstrated different patterns of the SFA scores among three different diagnostic groups. Moreover, discriminant analysis of the scores showed a high percentage of children correctly classified into their diagnostic groups. The overall results supported the psychometric properties of the SFA—Chinese version.


2013 ◽  
Vol 25 (9) ◽  
pp. 1503-1511 ◽  
Author(s):  
Florindo Stella ◽  
Orestes Vicente Forlenza ◽  
Jerson Laks ◽  
Larissa Pires de Andrade ◽  
Michelle A. Ljubetic Avendaño ◽  
...  

ABSTRACTBackground:Patients with dementia may be unable to describe their symptoms, and caregivers frequently suffer emotional burden that can interfere with judgment of the patient's behavior. The Neuropsychiatric Inventory-Clinician rating scale (NPI-C) was therefore developed as a comprehensive and versatile instrument to assess and accurately measure neuropsychiatric symptoms (NPS) in dementia, thereby using information from caregiver and patient interviews, and any other relevant available data. The present study is a follow-up to the original, cross-national NPI-C validation, evaluating the reliability and concurrent validity of the NPI-C in quantifying psychopathological symptoms in dementia in a large Brazilian cohort.Methods:Two blinded raters evaluated 312 participants (156 patient-knowledgeable informant dyads) using the NPI-C for a total of 624 observations in five Brazilian centers. Inter-rater reliability was determined through intraclass correlation coefficients for the NPI-C domains and the traditional NPI. Convergent validity included correlations of specific domains of the NPI-C with the Brief Psychiatric Rating Scale (BPRS), the Cohen-Mansfield Agitation Index (CMAI), the Cornell Scale for Depression in Dementia (CSDD), and the Apathy Inventory (AI).Results:Inter-rater reliability was strong for all NPI-C domains. There were high correlations between NPI-C/delusions and BPRS, NPI-C/apathy-indifference with the AI, NPI-C/depression-dysphoria with the CSDD, NPI-C/agitation with the CMAI, and NPI-C/aggression with the CMAI. There was moderate correlation between the NPI-C/aberrant vocalizations and CMAI and the NPI-C/hallucinations with the BPRS.Conclusion:The NPI-C is a comprehensive tool that provides accurate measurement of NPS in dementia with high concurrent validity and inter-rater reliability in the Brazilian setting. In addition to universal assessment, the NPI-C can be completed by individual domains.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Hui Wang ◽  
Haifeng Li ◽  
Jiangping Wang ◽  
Huiying Jin

The Alberta Infant Motor Scale (AIMS) is widely used to screen for delays in motor development in high-risk infants, but its reliability and validity in Chinese infants have not been investigated. To examine the reliability and concurrent validity of AIMS in high-risk infants aged 0-9 months in China, this single-center study enrolled 50 high-risk infants aged 0-9 months (range, 0.17-9.27; average, 4.14±2.02), who were divided into two groups: 0-3 months (n=23) and 4-9 months (n=27). A physical therapist evaluated the infants with AIMS, with each evaluation video-recorded. To examine interrater reliability, two other evaluators calculated AIMS scores by observing the videos. To measure intrarater reliability, the two evaluators rescored AIMS after >1 month, using the videos. Concurrent validity was assessed by comparing results between AIMS and the Peabody Developmental Motor Scale-2 (PDMS-2). For all age groups analyzed (0-3, 4-9, and 0-9 months), intraclass correlation coefficients (ICCs) for AIMS total score were high for both intrarater comparisons (0.811-0.995) and interrater comparisons (0.982-0.997). AIMS total scores were well correlated with all PDMS-2 subtest scores (ICC=0.751-0.977 for reflexes, stationary, locomotion, grasping, and visual-motor integration subsets). However, the fifth percentile of AIMS total score was only moderately correlated with the gross motor quotient, fine motor quotient, and total motor quotient subtests of PDMS-2 (kappa=0.580, 0.601, and 0.724, respectively). AIMS has acceptable reliability and concurrent validity for screening of motor developmental delay in high-risk infants in China.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Minjeong Kim ◽  
Ja Young Oh ◽  
Seon Ha Bae ◽  
Seung Hyeun Lee ◽  
Won Jun Lee ◽  
...  

AbstractWe evaluated the reliability and validity of the 5-scale grading system to interpret the point-of-care immunoassay for tear matrix metalloproteinase (MMP)-9. Six observers graded red bands of photographs of the readout window in MMP-9 immunoassay kit (InflammaDry) two times with 2-week interval based on the 5-scale grading system (i.e. grade 0–4). Interobserver and intraobserver reliability were evaluated using intraclass correlation coefficients. The interobserver agreements were analyzed according to the severity of tear MMP-9 expression. To validate the system, a concentration calibration curve was made using MMP-9 solutions with reference concentrations, then the distribution of MMP-9 concentrations was analyzed according to the 5-scale grading system. Both intraobserver and interobserver reliability was excellent. The readout grades were significantly correlated with the quantified colorimetric densities. The interobserver variance of readout grades had no correlation with the severity of the measured densities. The band density continued to increase up to a maximal concentration (i.e. 5000 ng/mL) according to the calibration curve. The difference of grades reflected the change of MMP-9 concentrations sensitively, especially between grade 2 and 4. Together, our data indicate that the subjective 5-scale grading system in the point-of-care MMP-9 immunoassay is an easy and reliable method with acceptable accuracy.


2021 ◽  
Author(s):  
Qi Zhang ◽  
Ke Zhang ◽  
Miao Li ◽  
Jiaxin Gu ◽  
Xintong Li ◽  
...  

Abstract Objectives To examine the validity and reliability of the Mandarin version of the Treatment Burden Questionnaire (TBQ) among stroke patients. Background Stroke patients need long-term management of symptoms and life situation, and treatment burden has recently emerged as a new concept that can influence the health outcomes during the rehabilitation process. Methods The convenience sampling method was used to recruit 187 cases of stroke patients in a tertiary grade hospital in Tianjin for a formal investigation. Item analysis, reliability and validity tests were carried out. The reliability test included internal consistency and test–retest reliability. And as well as content, structure and convergent validity were performed for the validity test. Results Of the 187 completed questionnaires, only 180 (96.3%) were suitable for analysis. According to the experts’ evaluation, the I-CVI of each item was from 0.833 to 1.000, and the S-CVI was 0.967. The exploratory factor analysis yielded three-factor components with a cumulative variation of 53.054%. Convergent validity was demonstrated using measures of Morisky’s Medication Adherence Scale 8 (r = –0.450, P < 0.01). All correlations between items and global scores ranged from 0.403 to 0.638. Internal consistency reliability and test–retest reliability were found to be acceptable, as indicated by a Cronbach’s α of 0.824 and an intraclass correlation coefficient of 0.846, respectively. Conclusions The Mandarin TBQ had acceptable validity and reliability. The use of TBQ in the assessment of treatment burden of stroke survivor may benefit health resources allocation and provide tailor therapeutic interventions to construct minimally disruptive care.


Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3065
Author(s):  
Ernest Kwesi Ofori ◽  
Shuaijie Wang ◽  
Tanvi Bhatt

Inertial sensors (IS) enable the kinematic analysis of human motion with fewer logistical limitations than the silver standard optoelectronic motion capture (MOCAP) system. However, there are no data on the validity of IS for perturbation training and during the performance of dance. The aim of this present study was to determine the concurrent validity of IS in the analysis of kinematic data during slip and trip-like perturbations and during the performance of dance. Seven IS and the MOCAP system were simultaneously used to capture the reactive response and dance movements of fifteen healthy young participants (Age: 18–35 years). Bland Altman (BA) plots, root mean square errors (RMSE), Pearson’s correlation coefficients (R), and intraclass correlation coefficients (ICC) were used to compare kinematic variables of interest between the two systems for absolute equivalency and accuracy. Limits of agreements (LOA) of the BA plots ranged from −0.23 to 0.56 and −0.21 to 0.43 for slip and trip stability variables, respectively. The RMSE for slip and trip stabilities were from 0.11 to 0.20 and 0.11 to 0.16, respectively. For the joint mobility in dance, LOA varied from −6.98–18.54, while RMSE ranged from 1.90 to 13.06. Comparison of IS and optoelectronic MOCAP system for reactive balance and body segmental kinematics revealed that R varied from 0.59 to 0.81 and from 0.47 to 0.85 while ICC was from 0.50 to 0.72 and 0.45 to 0.84 respectively for slip–trip perturbations and dance. Results of moderate to high concurrent validity of IS and MOCAP systems. These results were consistent with results from similar studies. This suggests that IS are valid tools to quantitatively analyze reactive balance and mobility kinematics during slip–trip perturbation and the performance of dance at any location outside, including the laboratory, clinical and home settings.


2014 ◽  
Vol 138 (6) ◽  
pp. 809-813
Author(s):  
Carolyn R. Vitek ◽  
Jane C. Dale ◽  
Henry A. Homburger ◽  
Sandra C. Bryant ◽  
Amy K. Saenger ◽  
...  

Context.— Systems-based practice (SBP) is 1 of 6 core competencies required in all resident training programs accredited by the Accreditation Council for Graduate Medical Education. Reliable methods of assessing resident competency in SBP have not been described in the medical literature. Objective.— To develop and validate an analytic grading rubric to assess pathology residents' analyses of SBP problems in clinical chemistry. Design.— Residents were assigned an SBP project based upon unmet clinical needs in the clinical chemistry laboratories. Using an iterative method, we created an analytic grading rubric based on critical thinking principles. Four faculty raters used the SBP project evaluation rubric to independently grade 11 residents' projects during their clinical chemistry rotations. Interrater reliability and Cronbach α were calculated to determine the reliability and validity of the rubric. Project mean scores and range were also assessed to determine whether the rubric differentiated resident critical thinking skills related to the SBP projects. Results.— Overall project scores ranged from 6.56 to 16.50 out of a possible 20 points. Cronbach α ranged from 0.91 to 0.96, indicating that the 4 rubric categories were internally consistent without significant overlap. Intraclass correlation coefficients ranged from 0.63 to 0.81, indicating moderate to strong interrater reliability. Conclusions.— We report development and statistical analysis of a novel SBP project evaluation rubric. The results indicate the rubric can be used to reliably assess pathology residents' critical thinking skills in SBP.


2008 ◽  
Vol 22 (6) ◽  
pp. 737-744 ◽  
Author(s):  
I-Ping Hsueh ◽  
Miao-Ju Hsu ◽  
Ching-Fan Sheu ◽  
Su Lee ◽  
Ching-Lin Hsieh ◽  
...  

Objective. To provide empirical justification for selecting motor scales for stroke patients, the authors compared the psychometric properties (validity, responsiveness, test-retest reliability, and smallest real difference [SRD]) of the Fugl-Meyer Motor Scale (FM), the simplified FM (S-FM), the Stroke Rehabilitation Assessment of Movement instrument (STREAM), and the simplified STREAM (S-STREAM). Methods. For the validity and responsiveness study, 50 inpatients were assessed with the FM and the STREAM at admission and discharge to a rehabilitation department. The scores of the S-FM and the S-STREAM were retrieved from their corresponding scales. For the test-retest reliability study, a therapist administered both scales on a different sample of 60 chronic patients on 2 occasions. Results. Only the S-STREAM had no notable floor or ceiling effects at admission and discharge. The 4 motor scales had good concurrent validity (rho ≥ .91) and satisfactory predictive validity (rho = .72-.77). The scales showed responsiveness (effect size d ≥ 0.34; standardized response mean ≥ 0.95; P < .0001), with the S-STREAM most responsive. The test-retest agreements of the scales were excellent (intraclass correlation coefficients ≥ .96). The SRD of the 4 scales was 10% of their corresponding highest score, indicating acceptable level of measurement error. The upper extremity and the lower extremity subscales of the 4 showed similar results. Conclusions. The 4 motor scales showed acceptable levels of reliability, validity, and responsiveness in stroke patients. The S-STREAM is recommended because it is short, responsive to change, and able to discriminate patients with severe or mild stroke.


2021 ◽  
Vol 12 ◽  
Author(s):  
Wei Xia ◽  
William Ho Cheung Li ◽  
Tingna Liang ◽  
Yuanhui Luo ◽  
Laurie Long Kwan Ho ◽  
...  

Objectives: This study conducted a linguistic and psychometric evaluation of the Chinese Counseling Competencies Scale-Revised (CCS-R).Methods: The Chinese CCS-R was created from the original English version using a standard forward-backward translation process. The psychometric properties of the Chinese CCS-R were examined in a cohort of 208 counselors-in-training by two independent raters. Fifty-three counselors-in-training were asked to undergo another counseling performance evaluation for the test-retest. The confirmatory factor analysis (CFA) was conducted for the Chinese CCS-R, followed by internal consistency, test-retest reliability, inter-rater reliability, convergent validity, and concurrent validity.Results: The results of the CFA supported the factorial validity of the Chinese CCS-R, with adequate construct replicability. The scale had a McDonald's omega of 0.876, and intraclass correlation coefficients of 0.63 and 0.90 for test-retest reliability and inter-rater reliability, respectively. Significantly positive correlations were observed between the Chinese CCS-R score and scores of performance checklist (Pearson's γ = 0.781), indicating a large convergent validity, and knowledge on drug abuse (Pearson's γ = 0.833), indicating a moderate concurrent validity.Conclusion: The results support that the Chinese CCS-R is a valid and reliable measure of the counseling competencies.Practice implication: The CCS-R provides trainers with a reliable tool to evaluate counseling students' competencies and to facilitate discussions with trainees about their areas for growth.


2020 ◽  
Author(s):  
Jiangang Sun ◽  
Yang Liu

BACKGROUND An increasing number of wrist-worn wearables are being examined in the context of health care. However, studies of their use during physical education (PE) lessons remain scarce. OBJECTIVE We aim to examine the reliability and validity of the Fizzo Smart Bracelet (Fizzo) in measuring heart rate (HR) in the laboratory and during PE lessons. METHODS In Study 1, 11 healthy subjects (median age 22.0 years, IQR 3.75 years) twice completed a test that involved running on a treadmill at 6 km/h for 12 minutes and 12 km/h for 5 minutes. During the test, participants wore two Fizzo devices, one each on their left and right wrists, to measure their HR. At the same time, the Polar Team2 Pro (Polar), which is worn on the chest, was used as the standard. In Study 2, we went to 10 schools and measured the HR of 24 students (median age 14.0 years, IQR 2.0 years) during PE lessons. During the PE lessons, each student wore a Polar device on their chest and a Fizzo on their right wrist to measure HR data. At the end of the PE lessons, the students and their teachers completed a questionnaire where they assessed the feasibility of Fizzo. The measurements taken by the left wrist Fizzo and the right wrist Fizzo were compared to estimate reliability, while the Fizzo measurements were compared to the Polar measurements to estimate validity. To measure reliability, intraclass correlation coefficients (ICC), mean difference (MD), standard error of measurement (SEM), and mean absolute percentage errors (MAPE) were used. To measure validity, ICC, limits of agreement (LOA), and MAPE were calculated and Bland-Altman plots were constructed. Percentage values were used to estimate the feasibility of Fizzo. RESULTS The Fizzo showed excellent reliability and validity in the laboratory and moderate validity in a PE lesson setting. In Study 1, reliability was excellent (ICC&gt;0.97; MD&lt;0.7; SEM&lt;0.56; MAPE&lt;1.45%). The validity as determined by comparing the left wrist Fizzo and right wrist Fizzo was excellent (ICC&gt;0.98; MAPE&lt;1.85%). Bland-Altman plots showed a strong correlation between left wrist Fizzo measurements (bias=0.48, LOA=–3.94 to 4.89 beats per minute) and right wrist Fizzo measurements (bias=0.56, LOA=–4.60 to 5.72 beats per minute). In Study 2, the validity of the Fizzo was lower compared to that found in Study 1 but still moderate (ICC&gt;0.70; MAPE&lt;9.0%). The Fizzo showed broader LOA in the Bland-Altman plots during the PE lessons (bias=–2.60, LOA=–38.89 to 33.69 beats per minute). Most participants considered the Fizzo very comfortable and easy to put on. All teachers thought the Fizzo was helpful. CONCLUSIONS When participants ran on a treadmill in the laboratory, both left and right wrist Fizzo measurements were accurate. The validity of the Fizzo was lower in PE lessons but still reached a moderate level. The Fizzo is feasible for use during PE lessons.