scholarly journals Visual Quality Assessment of Posterior Capsule Opacification Using Optical Quality Analysis System (OQAS)

2017 ◽  
Vol 2017 ◽  
pp. 1-4 ◽  
Author(s):  
Hui Zhang ◽  
Jing Wang

Objective. To evaluate intraocular scattering in eyes with posterior capsule opacification by means of an objective scatter index (OSI) obtained from double-pass images of optical quality assessment system (OQAS TM II) and to determine the indication for laser capsulotomy when patients report visual disturbances without decreased visual acuity. Methods. In this prospective, observational, and nonconsecutive case series study, a total of 32 eyes of 29 patients are diagnosed with posterior capsule opacification after age-associated cataract were analyzed. Patient examination included age, the period after cataract surgery, logMAR best corrected visual acuity (BCVA), and OSI. Results. We found a significant decrease in the BCVA and increase in the OSI with the development of posterior capsule opacification. The decrease of BCVA was statistically correlated with the increase of OSI (r=0.812, P<0.01). In patients who reported visual disturbances without decreased visual acuity, OSI decreased to <1.3 and subjective symptoms were resolved in all cases although there was no significant improvement in visual acuity after laser capsulotomy. Conclusions. The results of our study showed that OSI is also a useful parameter for objectively evaluating posterior capsule opacification. OSI may help predict laser capsulotomy in patients who report visual disturbances without decreased visual acuity.

2022 ◽  
Vol 9 (1) ◽  
pp. 75-81
Author(s):  
Muhammad Bilal ◽  
Shafqat Ali Shah ◽  
Marina Murad ◽  
Saad Ali ◽  
Ammad Ali ◽  
...  

OBJECTIVES: To determine the frequency of complications following cataract surgery in diabetic patients admitted in the ophthalmology unit. METHODOLOGY: A prospective descriptive interventional case series study was conducted after approval of the ethical committee, from June 2017-June 2020 at the Ophthalmology department MTI-MMC. A total of 129 patients from either gender were enrolled in study. All the study patients went through detailed history and complete ocular examination. After necessary investigations, surgical procedure was carried out. Results were analyzed through the SPSS-24 version. RESULTS: Out of the total 129 eyes of the diabetic patients, fifty-nine (45.7%) were males and seventy (54.3%) were females with a ratio of 1:1.2. Uveitis leads the chart in complications found in twenty (15.50%) eyes while PODR being the least common found in only ten (7.75%) eyes. Worse visual acuity was observed in fourteen (10.85%) eyes. Striate keratopathy and posterior capsule opacification were found in sixteen (12.40%) and fifteen (11.62%) eyes respectively. Among the patients, 15.7% were having more than one complication during follow-up visits and eighty-eight (68.2%) eyes were found to have none complication. The age group 51-60 years observed frequent complications as compared to other groups. Similarly female gender (38.57%) has frequent complications as compared to males (2.7%). CONCLUSION: The study concludes Uveitis as the most common complication observed in 15.50% 0f the eyes while worse visual acuity (10.85%) and progression of diabetic retinopathy (7.75%) being the least common. Striate keratopathy was found in 12.40% while posterior capsule opacification in 11.62% of the eyes.


2018 ◽  
Vol 28 (4) ◽  
pp. 419-424 ◽  
Author(s):  
Jorge L Alió ◽  
Ana B Plaza-Puche ◽  
Jorge L Alió del Barrio ◽  
Pedro Amat-Peral ◽  
Vicente Ortuño ◽  
...  

Purpose: To evaluate clinical and visual outcomes, quality of near vision, and intraocular optical quality of patients bilaterally implanted with a trifocal PanOptix intraocular lens. Methods: In this prospective consecutive case-series study, 52 eyes of 26 bilateral patients (mean age, 60.2 ± 7.4 years) were implanted with the AcrySof IQ Panoptix intraocular lens. Visual acuity, defocus curve, contrast sensitivity (Pelli-Robson test), near activity visual questionnaire, and internal aberrations with Osiris were evaluated. A prototype light-distortion analyzer was used to quantify the postoperative light-distortion indices. The follow-up was 6 months after surgery. Results: Uncorrected, corrected distance, and uncorrected near visual acuities improved with the surgery (p ≤ 0.02). Distance corrected near visual acuity was 0.13 ± 0.10, 0.13 ± 0.13, and 0.13 ± 0.08 at 1, 3, and 6 months after surgery, respectively (p = 0.82). Distance corrected intermediate visual acuities were 0.09 ± 0.13, 0.13 ± 0.15, and 0.12 ± 0.12 at 1, 3, and 6 months, postoperatively. Binocular contrast sensitivity was 1.86 ± 0.15 Log Units. Defocus curve provided a visual acuity equal or better to 0.30 LogMAR between defocus levels of +0.50 to −3.00 D. The near activity visual questionnaire scores improved significantly with the surgery (p < 0.01). Conclusion: The AcrySof IQ Panoptix intraocular lens is able to restore visual function with an acceptable intermediate and near vision after cataract surgery with good contrast sensitivity and an improvement in the near activity visual questionnaire.


2019 ◽  
Author(s):  
BO LU ◽  
Weijie Zhu ◽  
Yu Fan ◽  
Dong Shi ◽  
Liwei Ma

Abstract Background: To evaluate whether the Optical Quality Analysis System (OQAS) can serve as a valuable additional indicator for appropriate posterior capsulotomy referral. Methods: One hundred and five eyes from 96 patients undergoing capsulotomy were divided into precapsulotomy logMAR CDVA ≤ 0.1 group and logMAR CDVA > 0.1 group. CDVA, and the Visual Function 14 index (VF-14) score were estimated before and 1 month after capsulotomy. Objective scattering index (OSI) value was measured by using the OQAS. Posterior capsule opacification (PCO) severity was assessed with Evaluation of PCO 2000 (EPCO 2000) software. Results:In logMAR CDVA > 0.1 group, the correlations of OSI, logMAR CDVA, EPCO score and VF-14 score were very strong preoperatively. In logMAR CDVA ≤ 0.1 group, preoperatively, OSI was correlated with logMAR CDVA (r = 0.451), EPCO score (r = 0.789), and VF-14 score (r = 0.852). LogMAR CDVA has weak correlation with VF-14 score (r = -0.384) and EPCO score (r = 0.566). VF-14 score was correlated with EPCO score (r = -0.669). In the logMAR CDVA ≤ 0.1 group, there was no significant difference in logMAR CDVA between precapsulotomy and postcapsulotomy (P > 0.05). In the two groups, all the other optical quality parameters were significantly improved after capsulotomy (P < 0.05). Conclusions:The OSI was useful for the evaluation of PCO and prediction of beneficial capsulotomy. Especially for patients with slight PCO and better visual acuity, OSI is more valuable than CDVA and a complete objectivity examination. Trial registration: The study protocol was registered at the Chinese Clinical Trial Registry. Register: ChiCTR1800018842 (Registered Date: October 13th, 2018). Keywords: Posterior capsule opacification, Objective scattering index, Capsulotomy, Visual Function 14 index, Visual outcomes


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Bo Lu ◽  
Weijie Zhu ◽  
Yu Fan ◽  
Dong Shi ◽  
Liwei Ma

Abstract Background A prospective cohort study was performed to evaluate whether the Optical Quality Analysis System (OQAS) can serve as a valuable additional indicator for appropriate posterior capsulotomy referral. Methods One hundred and five eyes from 96 patients undergoing capsulotomy were divided into precapsulotomy logMAR CDVA ≤0.1 group and logMAR CDVA > 0.1 group. CDVA, and the Visual Function 14 index (VF-14) score were estimated before and 1 month after capsulotomy. The objective scattering index (OSI) value was measured by using the OQAS. Posterior capsule opacification (PCO) severity was assessed with Evaluation of PCO 2000 (EPCO 2000) software. Results In logMAR CDVA > 0.1 group, the correlations of OSI, logMAR CDVA, EPCO score and VF-14 score were very strong preoperatively. In logMAR CDVA ≤0.1 group, preoperatively, OSI was correlated with logMAR CDVA (r = 0.451), EPCO score (r = 0.789), and VF-14 score (r = 0.852). LogMAR CDVA has weak correlation with VF-14 score (r = − 0.384) and EPCO score (r = 0.566). VF-14 score was correlated with EPCO score (r = − 0.669). In the logMAR CDVA ≤0.1 group, there was no significant difference in logMAR CDVA between precapsulotomy and postcapsulotomy (P > 0.05). In the two groups, all the other optical quality parameters were significantly improved after capsulotomy (P < 0.05). In logMAR CDVA > 0.1 group, the area under the curve of the ROC of the OSI was 0.996 (P = 0.000). In logMAR CDVA ≤0.1 group, the area under the curve of the ROC of the OSI was 0.943 (P = 0.000). Conclusions The OSI was useful for evaluating of PCO and prediction of beneficial capsulotomy. Especially for patients with slight PCO and better visual acuity, OSI is more valuable than CDVA and completely objective examination. Trial registration The study protocol was registered at the Chinese Clinical Trial Registry. Register: ChiCTR1800018842 (Registered Date: October 13th, 2018).


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Xiao-ling Jiao ◽  
Jun Li ◽  
Zhe Yu ◽  
Ping-hui Wei ◽  
Hui Song

Abstract Background To compare visual performance between the iris-fixated phakic intraocular len (pIOL) and implantable collamer len (ICL) to correct high myopia. Methods Twenty-four eyes underwent iris-fixated pIOL implantation and 24 eyes underwent ICL implantation. At the 6-month follow-up, the best-corrected visual acuity (BCVA) and uncorrected distance visual acuity (UDVA) were compared between the iris-fixated pIOL and ICL groups. The objective scatter index (OSI), modulation transfer function (MTF) cutoff, and ocular aberrations were performed to evaluate postoperative visual quality between the two groups. Results No significant difference was found in UDVA, BCVA, and spherical equivalent between the iris-fixated pIOL and ICL groups (P > 0.05). Six months after surgery, the following values were significantly higher in the ICL group than in the iris-fixated pIOL group: MTF cutoff, strehl ratio and optical quality analysis system values at contrasts of 9 %, 20 %, and 100 % (P < 0.01). The OSI in the iris-fixated pIOL group was higher than in the ICL group 6 months after surgery (P < 0.01). All high-order aberrations were slightly more severe in the iris-fixated pIOL group than in the ICL group 6 months after surgery, although only trefoil (P = 0.023) differed significantly in this regard. Conclusions Both iris-fixated lenses and ICLs can provide good visual acuity. ICLs confer better visual performance in MTF-associated parameters and induce less intraocular light scattering than iris-fixated pIOLs.


2013 ◽  
Vol 5 ◽  
pp. OED.S12672
Author(s):  
Kagmeni Giles ◽  
Moukouri Ernest ◽  
Domngang Christelle ◽  
Nguefack-Tsague Georges ◽  
Cheuteu Raoul ◽  
...  

We assessed the outcomes of the use of anterior chamber foldable lens for unilateral aphakia correction at the University Teaching Hospital of Yaounde. In this retrospective, non-comparative, consecutive case series study, we reviewed the records of patients who underwent an operation for aphakia correction by the means of injection of an angular supported foldable lens between January 2009 and December 2011 in the University Teaching Hospital Yaounde. Student's paired t-test was carried out to compare preoperative and postoperative visual acuity (VA) and intraocular pressure (TOP). P-values less than 0.05 were considered statistically significant. Twenty-one patients were included in the study; twelve were male (57.1%) and nine were female (42.9%). The mean age was 55.38 ± 17.67 years (range 9–75 years). The mean follow-up duration was 5.95 ± 3.14 months (range 2–12 months). The mean logMAR visual acuity was 1.26 ± 0.46 pre-operatively and 0.78 ± 0.57 post-operatively ( P = 0.003). The change in intraocular pressure was not statistically significant. Complications included intraocular hypertension (over 21 mmHg) in 3 patients (14.3%) and macular edema, pupillar ovalization, and retinal detachment in one patient each. The results indicate that injection of an angular support foldable lens in the anterior chamber is a useful technique for the correction of aphakia in eyes without capsular support. More extended follow-up, however, and a larger series of patients are needed to ascertain the effectiveness and safety of this procedure.


2002 ◽  
Vol 28 (4) ◽  
pp. 662-669 ◽  
Author(s):  
Michael T. Halpern ◽  
Dave Covert ◽  
Carmelina Battista ◽  
Arthur J. Weinstein ◽  
Ralph D. Levinson ◽  
...  

2022 ◽  
Author(s):  
Mahmoud Ekram ◽  
Ahmed Mohamed Kamal Elshafei ◽  
Asmaa Anwar Mohamed ◽  
Mohamed Farouk Sayed Othman Abdelkader

Abstract Purpose: To evaluate the anatomical effects of implantable phakic contact lens (IPCL) (Care Group, India) on anterior segment and its visual outcomes .Patients and methods: In a prospective interventional case series study, 60 highly myopic eyes of 32 patients were subjected to IPCL implantation in the Ophthalmology Department of Minia University Hospital, Egypt from January 2019 to June 2021. All patients had complete ophthalmic examination and were followed up for 1 year. Pentacam was used for preoperative and postoperative estimation of anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV) and IPCL vault in the 1st, 3rd, and 12th months. Assessment of corneal endothelium was done using specular microscope preoperatively and after 12 months. Preoperative and postoperative refraction and visual acuity were measured. Results: There was a statistically significant decrease in ACD, ACA, and ACV. There was no significant difference between preoperative and postoperative mean intraocular pressure (IOP) by the 12th month (P=0.163). The mean preoperative endothelial cell count (ECD) was significantly reduced from 2929.3±248 cells/mm2 to 2737.9±303 cells/mm2 at the 12th month (P<0.001). with a statistically highly significant improvement of mean Log Mar uncorrected visual acuity (UCVA) from 1.48±0.19 preoperatively to 0.46±0.11 by the end of follow up (P<0.001) with insignificant difference between preoperative best corrected visual acuity (BCVA) and postoperative UCVA (P=0.209). In the 12th month, the mean vault was 240±540 μm. No sight threatening complications occurred.Conclusion: Although IPCL induced anatomical changes, it was safe and effective for correction of high myopia.


2021 ◽  
Vol 2021 ◽  
pp. 1-8
Author(s):  
Ahmed Ibrahim Basiony ◽  
Moataz Fayez ElSawy ◽  
Mahmoud Mohamed Ismail ◽  
Mohamed Samy Abd ElAziz ◽  
Mahmoud Tawfik KhalafAllah ◽  
...  

Background. Intrastromal corneal ring segments are widely adopted for keratoconus management. However, the complete ring (Myoring) was proposed to be superior in advanced cases. Myoring can be implanted either via femtoassisted or manual dissection techniques. A comparison between both techniques can delineate any differences in the outcomes. Methods. This was a prospective interventional case series study. Sixty-four eyes with progressive advanced keratoconus were enrolled: 36 and 28 had femtoassisted or manual Myoring, respectively. Uncorrected visual acuity (UCVA), corrected distance visual acuity (CDVA), maximal keratometry (Kmax), spherical equivalent (SE) and corneal thinnest location were measured in all eyes preoperatively and at one, six, and 12 months postoperatively. Epi-off corneal cross-linking (CXL) was performed eight weeks after Myoring implantation for all cases. Results. Femtoassisted Myoring dissection significantly improved UCVA and CDVA from 0.1 ± 0.06 and 0.18 ± 0.1 preoperatively to 0.29 ± 0.08 and 0.43 ± 0.1 at 12 months. Also, manual technique similarly enhanced UCVA and CDVA from 0.11 ± 0.05 and 0.2 ± 0.1 preoperatively to 0.27 ± 0.2 and 0.4 ± 0.2 at 12 months. In terms of safety, while no cases of ring extrusion were encountered with the femtoassisted technique, six (21.4%) cases of extrusion were encountered in the manual group. Conclusion. Femtoassisted or manual Myoring technique followed by CXL is an effective choice for advanced progressive keratoconus. Although it did not reach a statistical significance, the high extrusion rate with manual dissection is a red flag to be considered.


2021 ◽  
Author(s):  
Hassan Hashemi ◽  
Mohammadreza Aghamirsalim ◽  
Saied Shahhoseini ◽  
Alireza Moghaddasi ◽  
Soheila Asgari

Abstract PurposeTo determine the two-year results of small incision lenticule extraction (SMILE) for correcting post-keratoplasty myopia and myopic astigmatism.MethodsIn this case-series study, 10 eyes of 10 patients with a 6-10-year history of successful deep lamellar keratoplasty (DALK) underwent SMILE using VisuMax laser platform. Ophthalmologic examinations and visual acuity and refraction measurement were done pre- and 1, 3, 6, 12, and 24 months postoperatively. Pentacam and Sirius imaging was done in the first and last follow-up session.ResultsThe mean age of the patients was 39.60±7.86 years. Six subjects were male. After two years, uncorrected distance visual acuity did not change in one eye and improved 1-6 lines in other eyes. Corrected distance visual acuity decreased in one eye, did not change in four eyes, and improved 1-8 lines in other eyes. The mean decrease of spherical equivalent, spherical error, and cylinder power was 1.92±1.96 diopter (D) (P=0.013), 0.70±3.05D (P=0.213), and 2.42±2.91D (P=0.024), respectively. The vector mean target induced astigmatism, surgical induced astigmatism, and difference vector was 1.30D@44˚, 1.11D@24˚, and 0.86D@73˚, respectively. Two years after surgery, vertical coma, horizontal coma, and spherical aberration increased by 0.44±0.51, 0.23±0.32, and 0.02±0.16µm respectively (all P>0.05) while trefoil reduced by 0.29±0.75µm (P=0.428).ConclusionSMILE is a successful procedure for reducing refraction and astigmatism after DALK in patients with moderate myopia and moderate to severe astigmatism and improves the visual acuity in these patients. Axis rotation during surgery may result in under-correction of astigmatism. Refinement of SMILE treatment nomogram for post-DALK cases seems necessary.


Sign in / Sign up

Export Citation Format

Share Document