scholarly journals Automatic Data Logging and Quality Analysis System for Mobile Devices

2017 ◽  
Vol 2017 ◽  
pp. 1-25 ◽  
Author(s):  
Yong-Yi Fanjiang ◽  
Chih-Pin Wu

The testing phase of mobile device products includes two important test projects that must be completed before shipment: the field trial and the beta user trial. During the field trial, the product is certified based on its integration and stability with the local operator’s system, and, during the beta user trial, the product is certified by multiple users regarding its daily use, where the goal is to detect and solve early problems. In the traditional approach used to issue returns, testers must log into a web site, fill out a problem form, and then go through a browser or FTP to upload logs; however, this is inconvenient, and problems are reported slowly. Therefore, we propose an “automatic logging analysis system” (ALAS) to construct a convenient test environment and, using a record analysis (log parser) program, automate the parsing of log files and have questions automatically sent to the database by the system. Finally, the mean time between failures (MTBF) is used to establish measurement indicators for the beta user trial.

2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Bo Lu ◽  
Weijie Zhu ◽  
Yu Fan ◽  
Dong Shi ◽  
Liwei Ma

Abstract Background A prospective cohort study was performed to evaluate whether the Optical Quality Analysis System (OQAS) can serve as a valuable additional indicator for appropriate posterior capsulotomy referral. Methods One hundred and five eyes from 96 patients undergoing capsulotomy were divided into precapsulotomy logMAR CDVA ≤0.1 group and logMAR CDVA > 0.1 group. CDVA, and the Visual Function 14 index (VF-14) score were estimated before and 1 month after capsulotomy. The objective scattering index (OSI) value was measured by using the OQAS. Posterior capsule opacification (PCO) severity was assessed with Evaluation of PCO 2000 (EPCO 2000) software. Results In logMAR CDVA > 0.1 group, the correlations of OSI, logMAR CDVA, EPCO score and VF-14 score were very strong preoperatively. In logMAR CDVA ≤0.1 group, preoperatively, OSI was correlated with logMAR CDVA (r = 0.451), EPCO score (r = 0.789), and VF-14 score (r = 0.852). LogMAR CDVA has weak correlation with VF-14 score (r = − 0.384) and EPCO score (r = 0.566). VF-14 score was correlated with EPCO score (r = − 0.669). In the logMAR CDVA ≤0.1 group, there was no significant difference in logMAR CDVA between precapsulotomy and postcapsulotomy (P > 0.05). In the two groups, all the other optical quality parameters were significantly improved after capsulotomy (P < 0.05). In logMAR CDVA > 0.1 group, the area under the curve of the ROC of the OSI was 0.996 (P = 0.000). In logMAR CDVA ≤0.1 group, the area under the curve of the ROC of the OSI was 0.943 (P = 0.000). Conclusions The OSI was useful for evaluating of PCO and prediction of beneficial capsulotomy. Especially for patients with slight PCO and better visual acuity, OSI is more valuable than CDVA and completely objective examination. Trial registration The study protocol was registered at the Chinese Clinical Trial Registry. Register: ChiCTR1800018842 (Registered Date: October 13th, 2018).


2021 ◽  
Vol 1964 (4) ◽  
pp. 042078
Author(s):  
N Revathi ◽  
P Sengottuvelan ◽  
J Thimmia Raja

2014 ◽  
Vol 48 (3) ◽  
pp. 25-42 ◽  
Author(s):  
Narayanaswamy Vedachalam ◽  
Gidugu Ananada Ramadass ◽  
Malayath Aravindakshan Atmanand

AbstractThis paper reviews the latest advancements in subsea technologies associated with the safety of deep-water human occupied vehicles. Human occupied submersible operations are required for deep-water activities, such as high-resolution bathymetry, biological and geological surveys, search activities, salvage operations, and engineering support for underwater operations. As this involves direct human presence, the system has to be extremely safe and reliable. Based on applicable IEC 61508 Standards for health, safety, and environment (HSE), the safety integrity level requirements for the submersible safety systems are estimated. Safety analyses are done on 10 critical submersible safety systems with the assumption that the submersible is utilized for 10 deep-water missions per year. The results of the analyses are compared with the estimated target HSE requirements, and it is found that, with the present technological maturity and safety-centered design, it is possible to meet the required safety integrity levels. By proper maintenance, it is possible to keep the mean time between failures to more than 9 years. The results presented shall serve as a model for designers to arrive at the required trade-off between the capital expenditure, operating expenditure, and required safety levels.


2012 ◽  
Vol 236-237 ◽  
pp. 839-843
Author(s):  
Xiao Meng Cui ◽  
Guang Xue Chen ◽  
Huan Mei Wang ◽  
Lin Lin Chen

In this study we present a new framework to assess line micro quality of multicolor prints adapted to a low-cost image quality analysis system based on common flatbed scanner. The contribution elements including quality metrics, measurement principle, applying methods and detection instrument, which were complemented and sorted in terms of ISO 13660 standard, were described and a case experiment was conducted to survey the output performance of both inkjet printer and xerographic printer, two most popular digital printing technologies. Their qualities were compared in details rendering angle such as width and straightness of line, raggedness and blurriness in line edges, as well as darkness and contrast in color. The results verify the efficiency and shortcomings of the framework. Meanwhile, the metric values let us take an investigation in the character of each digital printing technology in micron size.


2019 ◽  
Vol 8 (3) ◽  
pp. 777-788
Author(s):  
Salami Ifedapo Abdullahi ◽  
Mohamed Hadi Habaebi ◽  
Noreha Abd Malik

Flow sensors are very essential in many aspects of our daily lives. Many of the industrial processes need a very consistent flow sensor to monitor and check for irregularities in their system. Therefore, flow sensor is an important tool for advanced operation in industrial environment. In this paper, the design and development of a 3D fabricated flow sensor was carried out using SolidWork 3D CAD. SolidWork Flow Simulation was used to model the effect the turbine flow sensor would have on a constant flowing water while MATLAB Simulink flow graph was created to visualize the effect of turbine flow sensor response with voltage input. Afterwards, the design was 3D printed using UP Plus 2 3D printer. The experimentation involved selection of sensors, coding to control the turbine flow sensor and automatic data logging and storage. During the design phase, the sensors and actuators were assembled using locally sourced material. Subsequently, under controlled laboratory environment, the turbine flow sensor was tested using a DC motor which was programmed to control the revolution per minute(rpm) of the turbine flow sensor. The rpm and velocity of the turbine flow meter was measured and stored in a database via Microsoft Excel using Cool Term Software. A total number of 517 readings were analysed to evaluate the performance of the turbine flow sensor. The result shows that the turbine flow meter is responsive to the motor input voltage and yielded accurate measurement of rpm and velocity of turbine flow meter.


2012 ◽  
Vol 468-471 ◽  
pp. 811-815
Author(s):  
Hai Feng Zhou ◽  
Kai Li ◽  
Jing De Dong ◽  
Yuan Qing Huang

This paper set up high-quality and highly efficient automatic data collection and analysis system by King View configuration in order to improve the reliability and stability of PV-Wind power system monitoring and decrease the workload, the design of its functions, structure, interface, control strategy and system variables, protection, and so on are detailed. It uses configuration software based on PC to exploit the operation interface in host computer, and adopt Wide-Plus Intelligent Instrument as the lower computer to data-acquisition. It monitors and controls PV-Wind power System, acquires field data, deals with device faults in real-time


Sign in / Sign up

Export Citation Format

Share Document