scholarly journals An Evaluation of the Gap Sizes of 3-Unit Fixed Dental Prostheses Milled from Sintering Metal Blocks

2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Jae-Kwan Jung

This study assessed the clinical acceptability of sintering metal-fabricated 3-unit fixed dental prostheses (FDPs) based on gap sizes. Ten specimens were prepared on research models by milling sintering metal blocks or by the lost-wax technique (LWC group). Gap sizes were assessed at 12 points per abutment (premolar and molar), 24 points per specimen (480 points in a total in 20 specimens). The measured points were categorized as marginal, axial wall, and occlusal for assessment in a silicone replica. The silicone replica was cut through the mesiodistal and buccolingual center. The four sections were magnified at 160x, and the thickness of the light body silicone was measured to determine the gap size, and gap size means were compared. For the premolar part, the mean (standard deviation) gap size was nonsignificantly (p=0.139) smaller in the SMB group (68.6 ± 35.6 μm) than in the LWC group (69.6 ± 16.9 μm). The mean molar gap was nonsignificantly smaller (p=0.852) in the LWC (73.9 ± 25.6 μm) than in the SMB (78.1 ± 37.4 μm) group. The gap sizes were similar between the two groups. Because the gap sizes were within the previously proposed clinically accepted limit, FDPs prepared by sintered metal block milling are clinically acceptable.

2013 ◽  
Vol 01 (02) ◽  
pp. 095-099
Author(s):  
Gursharan Singh ◽  
Nishtha Madan ◽  
Mandeep Kumar ◽  
Cherry Walia ◽  
Opinder Singh

AbstractMost patients are concerned about the anticipated length of service and reasons of replacement of fixed dental prostheses (FPDs). This study tried to find out relationship among various factors causing failures in fixed dental prostheses. Patients treated with fixed dental prostheses were examined clinically and radiographically. A group of 106 patients were evaluated for unsatisfactory restorations. These groups of patients produced records of initial treatment to ascertain the length of service of restoration. The mean survival period of fixed dental prostheses was 7.5 years. This investigation helped find causes for failures and survival period of various FPDs. Among the reasons of failures, caries was the most frequently observed (24.2%), followed by defective margin (18.2%), unsatisfactory esthetics (15.2%), retention problem (11.7%), periodontal disease (8.8%), fractured tooth (10.6%), periapical lesion (5.8%), porcelain fracture (4.2%) and others (1.3%). Causes of failures were also grouped into two groups (Mechanical & Oral diseases) for comparison. The Mechanical group showed higher failure percentage (59.9%) as compared to Oral diseases group (38.8%).


2021 ◽  
Vol 11 (12) ◽  
pp. 5617
Author(s):  
Maurizio De Francesco ◽  
Edoardo Stellini ◽  
Stefano Granata ◽  
Sergio Mazzoleni ◽  
Francesco Saverio Ludovichetti ◽  
...  

Background: Discordant opinions have emerged among clinicians and researchers regarding a digital impression for full-arch implant-supported fixed dental prostheses (FDPs). The purpose of this study was to assess the fit of screw-retained milled frameworks on six implants realized from digital impressions through the Sheffield test. Methods: One patient received a maxillary full-arch implant-supported FDP. Six months after the surgical procedure, ten intraoral full-arch digital impressions were performed to mill ten frameworks. To clinically assess the fit, the Sheffield test was applied for all frameworks. The gaps among the frameworks and the implant analogs were measured using a microscope on the master model realized with a traditional impression. The Wilcoxon sum-rank test was used to compare the misfit value among the different implant positions. Results: The Sheffield test did not show gaps in the framework–implant interfaces when the screw was completely tightened on the more distal implant for all the milled frameworks. The mean misfit value calculated after microscope examination was 38 ± 5 μm. Differences that were statistically significant emerged when the misfit values of central positions were compared with other values. Conclusions: The use of full-arch implant digital impressions represents a viable alternative to traditional impressions for the fabrication of implant-supported FDPs.


1969 ◽  
Vol 14 (9) ◽  
pp. 470-471
Author(s):  
M. DAVID MERRILL
Keyword(s):  

1972 ◽  
Vol 28 (03) ◽  
pp. 447-456 ◽  
Author(s):  
E. A Murphy ◽  
M. E Francis ◽  
J. F Mustard

SummaryThe characteristics of experimental error in measurement of platelet radioactivity have been explored by blind replicate determinations on specimens taken on several days on each of three Walker hounds.Analysis suggests that it is not unreasonable to suppose that error for each sample is normally distributed ; and while there is evidence that the variance is heterogeneous, no systematic relationship has been discovered between the mean and the standard deviation of the determinations on individual samples. Thus, since it would be impracticable for investigators to do replicate determinations as a routine, no improvement over simple unweighted least squares estimation on untransformed data suggests itself.


2020 ◽  
Vol 1 (2) ◽  
pp. 56-66
Author(s):  
Irma Linda

Background: Early marriages are at high risk of marital failure, poor family quality, young pregnancies at risk of maternal death, and the risk of being mentally ill to foster marriage and be responsible parents. Objective: To determine the effect of reproductive health education on peer groups (peers) on the knowledge and perceptions of adolescents about marriage age maturity. Method: This research uses the Quasi experimental method with One group pre and post test design, conducted from May to September 2018. The statistical analysis used in this study is a paired T test with a confidence level of 95% (α = 0, 05). Results: There is an average difference in the mean value of adolescent knowledge between the first and second measurements is 0.50 with a standard deviation of 1.922. The mean difference in mean scores of adolescent perceptions between the first and second measurements was 4.42 with a standard deviation of 9.611. Conclusion: There is a significant difference between adolescent knowledge on the pretest and posttest measurements with a value of P = 0.002, and there is a significant difference between adolescent perceptions on the pretest and posttest measurements with a value of p = 0.001. Increasing the number of facilities and facilities related to reproductive health education by peer groups (peers) in adolescents is carried out on an ongoing basis at school, in collaboration with local health workers as prevention of risky pregnancy.


1988 ◽  
Vol 60 (1) ◽  
pp. 1-29 ◽  
Author(s):  
E. D. Young ◽  
J. M. Robert ◽  
W. P. Shofner

1. The responses of neurons in the ventral cochlear nucleus (VCN) of decerebrate cats are described with regard to their regularity of discharge and latency. Regularity is measured by estimating the mean and standard deviation of interspike intervals as a function of time during responses to short tone bursts (25 ms). This method extends the usual interspike-interval analysis based on interval histograms by allowing the study of temporal changes in regularity during transient responses. The coefficient of variation (CV), equal to the ratio of standard deviation to mean interspike interval, is used as a measure of irregularity. Latency is measured as the mean and standard deviation of the latency of the first spike in response to short tone bursts, with 1.6-ms rise times. 2. The regularity and latency properties of the usual PST histogram response types are shown. Five major PST response type classes are used: chopper, primary-like, onset, onset-C, and unusual. The presence of a prepotential in a unit's action potentials is also noted; a prepotential implies that the unit is recorded from a bushy cell. 3. Units with chopper PST histograms give the most regular discharge. Three varieties of choppers are found. Chop-S units (regular choppers) have CVs less than 0.35 that are approximately constant during the response; chop-S units show no adaptation of instantaneous rate, as measured by the inverse of the mean interspike interval. Chop-T units have CVs greater than 0.35, show an increase in irregularity during the response and show substantial rate adaptation. Chop-U units have CVs greater than 0.35, show a decrease in irregularity during the response, and show a variety of rate adaptation behaviors, including negative adaptation (an increase in rate during a short-tone response). Irregular choppers (chop-T and chop-U units) rarely have CVs greater than 0.5. Choppers have the longest latencies of VCN units; all three groups have mean latencies at least 1 ms longer than the shortest auditory nerve (AN) fiber mean latencies. 4. Chopper units are recorded from stellate cells in VCN (35, 42). Our results for chopper units suggest a model for stellate cells in which a regularly firing action potential generator is driven by the summation of the AN inputs to the cell, where the summation is low-pass filtered by the membrane capacitance of the cell.(ABSTRACT TRUNCATED AT 400 WORDS)


Cancers ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 2421
Author(s):  
Roberta Fusco ◽  
Vincenza Granata ◽  
Mauro Mattace Raso ◽  
Paolo Vallone ◽  
Alessandro Pasquale De Rosa ◽  
...  

Purpose. To combine blood oxygenation level dependent magnetic resonance imaging (BOLD-MRI), dynamic contrast enhanced MRI (DCE-MRI), and diffusion weighted MRI (DW-MRI) in differentiation of benign and malignant breast lesions. Methods. Thirty-seven breast lesions (11 benign and 21 malignant lesions) pathologically proven were included in this retrospective preliminary study. Pharmaco-kinetic parameters including Ktrans, kep, ve, and vp were extracted by DCE-MRI; BOLD parameters were estimated by basal signal S0 and the relaxation rate R2*; and diffusion and perfusion parameters were derived by DW-MRI (pseudo-diffusion coefficient (Dp), perfusion fraction (fp), and tissue diffusivity (Dt)). The correlation coefficient, Wilcoxon-Mann-Whitney U-test, and receiver operating characteristic (ROC) analysis were calculated and area under the ROC curve (AUC) was obtained. Moreover, pattern recognition approaches (linear discrimination analysis and decision tree) with balancing technique and leave one out cross validation approach were considered. Results. R2* and D had a significant negative correlation (−0.57). The mean value, standard deviation, Skewness and Kurtosis values of R2* did not show a statistical significance between benign and malignant lesions (p > 0.05) confirmed by the ‘poor’ diagnostic value of ROC analysis. For DW-MRI derived parameters, the univariate analysis, standard deviation of D, Skewness and Kurtosis values of D* had a significant result to discriminate benign and malignant lesions and the best result at the univariate analysis in the discrimination of benign and malignant lesions was obtained by the Skewness of D* with an AUC of 82.9% (p-value = 0.02). Significant results for the mean value of Ktrans, mean value, standard deviation value and Skewness of kep, mean value, Skewness and Kurtosis of ve were obtained and the best AUC among DCE-MRI extracted parameters was reached by the mean value of kep and was equal to 80.0%. The best diagnostic performance in the discrimination of benign and malignant lesions was obtained at the multivariate analysis considering the DCE-MRI parameters alone with an AUC = 0.91 when the balancing technique was considered. Conclusions. Our results suggest that the combined use of DCE-MRI, DW-MRI and/or BOLD-MRI does not provide a dramatic improvement compared to the use of DCE-MRI features alone, in the classification of breast lesions. However, an interesting result was the negative correlation between R2* and D.


2021 ◽  
Vol 9 (6) ◽  
pp. 585
Author(s):  
Minghao Wu ◽  
Leen De Vos ◽  
Carlos Emilio Arboleda Chavez ◽  
Vasiliki Stratigaki ◽  
Maximilian Streicher ◽  
...  

The present work introduces an analysis of the measurement and model effects that exist in monopile scour protection experiments with repeated small scale tests. The damage erosion is calculated using the three dimensional global damage number S3D and subarea damage number S3D,i. Results show that the standard deviation of the global damage number σ(S3D)=0.257 and is approximately 20% of the mean S3D, and the standard deviation of the subarea damage number σ(S3D,i)=0.42 which can be up to 33% of the mean S3D. The irreproducible maximum wave height, chaotic flow field and non-repeatable armour layer construction are regarded as the main reasons for the occurrence of strong model effects. The measurement effects are limited to σ(S3D)=0.039 and σ(S3D,i)=0.083, which are minor compared to the model effects.


2021 ◽  
Vol 11 (9) ◽  
pp. 3770
Author(s):  
Monica Tatarciuc ◽  
George Alexandru Maftei ◽  
Anca Vitalariu ◽  
Ionut Luchian ◽  
Ioana Martu ◽  
...  

Inlay-retained dental bridges can be a viable minimally invasive alternative when patients reject the idea of implant therapy or conventional retained full-coverage fixed dental prostheses, which require more tooth preparation. Inlay-retained dental bridges are indicated in patients with good oral hygiene, low susceptibility to caries, and a minimum coronal tooth height of 5 mm. The present study aims to evaluate, through the finite element method (FEM), the stability of these types of dental bridges and the stresses on the supporting teeth, under the action of masticatory forces. The analysis revealed the distribution of the load on the bridge elements and on the retainers, highlighting the areas of maximum pressure. The results of our study demonstrate that the stress determined by the loading force cannot cause damage to the prosthetic device or to abutment teeth. Thus, it can be considered an optimal economical solution for treating class III Kennedy edentation in young patients or as a provisional pre-implant rehabilitation option. However, special attention must be paid to its design, especially in the connection area between the bridge elements, because the connectors and the retainers represent the weakest parts.


Sign in / Sign up

Export Citation Format

Share Document