scholarly journals The Hazard Content of Cadmium, Lead, and Other Trace Elements in Some Medicinal Herbs and Their Water Infusions

2017 ◽  
Vol 2017 ◽  
pp. 1-8 ◽  
Author(s):  
Fuad A. Ababneh

54 samples belonging to 23 herbal species (15 individuals and 8 mixtures) were analyzed for their contents of heavy metals in the raw materials and in their water infusions. Trace and toxic elements in these samples were determined by using inductively coupled plasma-atomic emission spectrometry (ICP-OES) following acid digestion. The order of decreasing mean metal concentrations in raw materials (mg/kg) was found to be as follows: Fe (440) > Mn (162) > Zn (45.8) > Cu (12) > Pb (10.4) > Ni (5.4) > Cr (2.9) > Co (0.91) > Cd (0.5). It was found that 21% of the analyzed samples contain both Cd and Pb above their permissible limits. However, the infusions produced from these plants were found to contain fewer amounts of metals than the raw materials. Studied metals had the following mass transfer percentages to the infusion solutions (Fe: 3.5%, Cd: 14%, Cr: 15%, Pb: 20%, Co: 29%, Ni: 31%, Zn: 36%, Cu: 48%, and Mn: 53%). The estimated daily intake calculated for the toxic elements Pb and Cd through the consumption of herbal infusions was far below the tolerable daily intake set by the World Health Organization (WHO).

2021 ◽  
Vol 87 (6) ◽  
pp. 20-24
Author(s):  
T. A. Karimova ◽  
G. L. Buchbinder ◽  
N. Romanov ◽  
S. V. Kachin

A method for the analysis of iron ore raw materials (IORM) using inductively coupled plasma atomic- emission spectrometry (ICP-AES) and Concentration Ratio Calibration (CRC) has been developed. However, the general eq. for calibration by concentration ratios used in analysis of metals and alloys was modified with allowance for the IORM characteristics: all the elements, except sulfur, were represented as oxides, iron was represented as FeO and Fe2O3, and the total of 100% included ignition losses (LOI). A variant of solving the equation is proposed, which allowed us to relate the relative concentrations of the components (the ratios of the mass fraction of the determined components to the mass fraction of iron oxide) to the ratio of the line intensities of the certain element and iron line measured on a spectrometer. The equation takes into account the content of FeO and LOI, which are determined by standard methods of analysis. A method for acid decomposition of the samples in autoclaves heated in a HotBlock 200 system is proposed: a sample weight of 0.25 g was decomposed in closed vessels at a temperature of 150 – 180°C in the mixture of HCl, HF and HNO3. The following components were determined in concentrates and pellets: Fe2O3, Fetot, Al2O3, CaO, Cr2O3, K2O, MgO, MnO, Na2O, P2O5, SiO2, TiO2, Co, Cu, Mo, Ni, Pb, S, V, Zn. The correctness of the developed method is confirmed by the analysis of SS of iron ore and iron concentrates, as well as by comparison with the results obtained by standardized methods. The proposed technique provides iron determination in iron ore raw materials with an accuracy no worse than that specified in GOST 23581, all other components are determined in a wider range of contents and with a higher accuracy.


2020 ◽  
Vol 86 (5) ◽  
pp. 16-21
Author(s):  
T. A. Karimova ◽  
G. L. Buchbinder ◽  
S. V. Kachin

Calibration by the concentration ratio provides better metrological characteristics compared to other calibration modes when using the inductively coupled plasma atomic emission spectrometry (ICP-AES) for analysis of geological samples and technical materials on their base. The main reasons for the observed improvement are: i) elimination of the calibration error of measuring vessels and the error of weighing samples of the analyzed materials from the total error of the analysis; ii) high intensity of the lines of base element; and iii) higher accuracy of measuring the ratio of intensities compared to that of measuring the absolute intensities. Calcium oxide is better suited as a base when using calibration by the concentration ratio in analysis of carbonate rocks, technical materials, slags containing less than 20% SiO2 and more than 20% CaO. An equation is derived to calculate the content of components determined in carbonate materials when using calibration by the concentration ratio. A method of ICP-AES with calibration by the concentration ratio is developed for determination of CaO (in the range of contents 20 – 100%), SiO2 (2.0 – 35%), Al2O3 (0.1 – 30%), MgO (0.1 – 20%), Fe2O3 (0.5 – 40%), Na2O (0.1 – 15%), K2O (0.1 – 5%), P2O5 (0.001 – 2%), MnO (0.01 – 2%), TiO2 (0.01 – 2.0%) in various carbonate materials. Acid decomposition of the samples in closed vessels heated in a HotBlock 200 system is proposed. Correctness of the procedure is confirmed in analysis of standard samples of rocks. The developed procedure was used during the interlaboratory analysis of the standard sample of slag SH17 produced by ZAO ISO (Yekaterinburg, Russia).


Sign in / Sign up

Export Citation Format

Share Document